Cuff-based blood pressure measurement: challenges and solutions

被引:4
|
作者
Pilz, N. [1 ,2 ]
Picone, D. S. [3 ,4 ]
Patzak, A. [5 ]
Opatz, O. S. [1 ]
Lindner, T. [1 ]
Fesseler, L. [1 ]
Heinz, V. [1 ]
Bothe, T. L. [1 ,3 ]
机构
[1] Charite Univ Med Berlin, Inst Physiol, Ctr Space Med & Extreme Environm Berlin, Virchowweg 6, D-10117 Berlin, Germany
[2] Hannover Med Sch, Dept Cardiol & Angiol, Hannover, Germany
[3] Univ Sydney, Sydney Sch Hlth Sci, Sydney, Australia
[4] Univ Tasmania, Menzies Inst Med Res, Hobart, Australia
[5] Charite Univ Med Berlin, Inst Physiol, D-10117 Berlin, Germany
基金
英国医学研究理事会;
关键词
Blood pressure monitoring; hypertension; cuff-based blood pressure measurement; accuracy of blood pressure measurement; home blood pressure monitoring; ambulatory blood pressure monitoring; office blood pressure monitoring; MEDICAL INSTRUMENTATION/EUROPEAN SOCIETY; MEASURING DEVICES; ATRIAL-FIBRILLATION; UNIVERSAL STANDARD; SLEEP-APNEA; HYPERTENSION/INTERNATIONAL ORGANIZATION; CLINICAL-PRACTICE; HYPERTENSION; HOME; VALIDATION;
D O I
10.1080/08037051.2024.2402368
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
ObjectiveAccurate measurement of arterial blood pressure (BP) is crucial for the diagnosis, monitoring, and treatment of hypertension. This narrative review highlights the challenges associated with conventional (cuff-based) BP measurement and potential solutions. This work covers each method of cuff-based BP measurement, as well as cuffless alternatives, but is primarily focused on ambulatory BP monitoring.ResultsManual BP measurement requires stringent training and standardized protocols which are often difficult to ensure in stressful and time-restricted clinical office blood pressure monitoring (OBPM) scenarios. Home Blood pressure monitoring (HBPM) can identify white-coat and masked hypertension but strongly depends on patient adherence to measurement techniques and procedure. The widespread use of nonvalidated automated HBPM devices raises further concerns about measurement accuracy. Ambulatory blood pressure measurement (ABPM) may be used in addition to OBPM. It is recommended to diagnose white-coat and masked hypertension as well as nocturnal BP and dipping, which are the BP values most predictive for major adverse cardiac events. Nonetheless, ABPM is limited by its non-continuous nature and susceptibility to measurement artefacts. This leads to poor overall reproducibility of ABPM results, especially regarding clinical parameters such as BP variability or dipping patterns.ConclusionsCuff-based BP measurement, despite some limitations, is vital for cardiovascular health assessment in clinical practice. Given the wide range of methodological limitations, the paradigm's potential for improvement is not yet fully realized. There are impactful and easily incorporated opportunities for innovation regarding the enhancement of measurement accuracy and reliability as well as the clinical interpretation of the retrieved data. There is a clear need for continued research and technological advancement to improve BP measurement as the premier tool for cardiovascular disease detection and management. Accurate blood pressure measurement is crucial for diagnosing, monitoring, and treating hypertension and preventing cardiovascular diseases.Manual blood pressure monitoring is common but may not always be reliable due to the stress and time constraints in clinical settings. It also fails to detect white-coat and masked hypertension.Home blood pressure monitoring helps to identify white-coat and masked hypertension but depends on how well patients follow the measurement instructions. Many devices are not validated, raising concerns about their accuracy.Ambulatory blood pressure measurement may be used in addition to office blood pressure measurement because of its better reproducibility and higher predictive value. It is recommended to diagnose white-coat and masked hypertension as well as nocturnal BP and dipping. However, it and can be prone to errors, affecting the reliability of results like BP variability or night-time dipping patterns.Patient's posture, physical activity, and conditions like atrial fibrillation can influence BP readings.Automated BP devices often have limitations in detecting measurement artefacts, underscoring the need for technological improvements.Despite its limitations, cuff-based blood pressure measurement is essential in everyday clinical practice but has unlocked potential for improvement.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] FIRST RESULTS OF THE COMPARISON OF A CUFFLESS 24 HOUR BLOOD PRESSURE MEASUREMENT DEVICE WITH A CUFF-BASED STANDARD DEVICE IN A REAL LIFE SETTING
    Krisai, P.
    Vischer, A.
    Meienberg, A.
    Mayr, M.
    Burkard, T.
    JOURNAL OF HYPERTENSION, 2018, 36 : E264 - E265
  • [32] Comparison between cuff-based and radial tonometry exercise-induced central blood pressure
    Francisco Morales-Acuna
    Brycen Ratcliffe
    Caleb Harrison
    Sierra Crowe
    Evan Bockover
    Robert Pawlak
    Alvaro N. Gurovich
    European Journal of Applied Physiology, 2019, 119 : 901 - 911
  • [33] Optimization and validation of a suprasystolic brachial cuff-based method for noninvasively estimating central aortic blood pressure
    Zhang, Xujie
    Wang, Yue
    Yin, Zhaofang
    Liang, Fuyou
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (03)
  • [34] Central blood pressure obtained by cuff-based oscillometry as a determinant of left ventricular hypertrophy in hypertensive patients
    Abdelmegid, Mohamed Aboel-Kassem F.
    Fouad, Doaa A.
    Beshay, Nardeen W. M.
    Mahran, Dalia G.
    Shams-eddin, Hamdy
    BLOOD PRESSURE MONITORING, 2023, 28 (06) : 322 - 329
  • [35] Arm cuff in the measurement of blood pressure
    Mattoo, TK
    AMERICAN JOURNAL OF HYPERTENSION, 2002, 15 (02) : 67S - 68S
  • [36] 12.03: Validation of A Brachial Cuff-Based Method for Assessing Central Blood Pressure at Rest and During Light Exercise
    L. M. Day
    D. M. Nicholson-Thomas
    K. M. Maki-Petaja
    C. M. McEniery
    I. B. Wilkinson
    Artery Research, 2011, 5 (4) : 201 - 201
  • [37] Discrepancy Between Tonometric Ambulatory and Cuff-Based Office Blood Pressure Measurements in Patients With Type 1 Diabetes
    Theilade, Simone
    Lajer, Maria
    Joergensen, Christel
    Persson, Frederik
    Rossing, Peter
    JOURNAL OF CLINICAL HYPERTENSION, 2012, 14 (10): : 686 - 693
  • [38] Peripheral and Central Blood Pressure Differences between Cuff-Based Supra-Systolic and Radial Tonometric Methods
    Tanveer, Hussain
    Asghar, Rizwan M.
    Minesh, Rajpal
    Narendra, Yallanki
    Michael, Hong
    Peter, Osmond
    Joseph, Izzo L.
    JOURNAL OF CLINICAL HYPERTENSION, 2013, 15
  • [39] Arterial pressure: agreement between a brachial cuff-based device and radial tonometry
    Park, Chloe M.
    Korolkova, Olga
    Davies, Justin E.
    Parker, Kim H.
    Siggers, Jennifer H.
    March, Katherine
    Tillin, Therese
    Chaturvedi, Nish
    Hughes, Alun D.
    JOURNAL OF HYPERTENSION, 2014, 32 (04) : 865 - 872
  • [40] Numerical validation of a suprasystolic brachial cuff-based method for estimating aortic pressure
    Liang, Fuyou
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 1053 - 1062