Cuff-based blood pressure measurement: challenges and solutions

被引:4
|
作者
Pilz, N. [1 ,2 ]
Picone, D. S. [3 ,4 ]
Patzak, A. [5 ]
Opatz, O. S. [1 ]
Lindner, T. [1 ]
Fesseler, L. [1 ]
Heinz, V. [1 ]
Bothe, T. L. [1 ,3 ]
机构
[1] Charite Univ Med Berlin, Inst Physiol, Ctr Space Med & Extreme Environm Berlin, Virchowweg 6, D-10117 Berlin, Germany
[2] Hannover Med Sch, Dept Cardiol & Angiol, Hannover, Germany
[3] Univ Sydney, Sydney Sch Hlth Sci, Sydney, Australia
[4] Univ Tasmania, Menzies Inst Med Res, Hobart, Australia
[5] Charite Univ Med Berlin, Inst Physiol, D-10117 Berlin, Germany
基金
英国医学研究理事会;
关键词
Blood pressure monitoring; hypertension; cuff-based blood pressure measurement; accuracy of blood pressure measurement; home blood pressure monitoring; ambulatory blood pressure monitoring; office blood pressure monitoring; MEDICAL INSTRUMENTATION/EUROPEAN SOCIETY; MEASURING DEVICES; ATRIAL-FIBRILLATION; UNIVERSAL STANDARD; SLEEP-APNEA; HYPERTENSION/INTERNATIONAL ORGANIZATION; CLINICAL-PRACTICE; HYPERTENSION; HOME; VALIDATION;
D O I
10.1080/08037051.2024.2402368
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
ObjectiveAccurate measurement of arterial blood pressure (BP) is crucial for the diagnosis, monitoring, and treatment of hypertension. This narrative review highlights the challenges associated with conventional (cuff-based) BP measurement and potential solutions. This work covers each method of cuff-based BP measurement, as well as cuffless alternatives, but is primarily focused on ambulatory BP monitoring.ResultsManual BP measurement requires stringent training and standardized protocols which are often difficult to ensure in stressful and time-restricted clinical office blood pressure monitoring (OBPM) scenarios. Home Blood pressure monitoring (HBPM) can identify white-coat and masked hypertension but strongly depends on patient adherence to measurement techniques and procedure. The widespread use of nonvalidated automated HBPM devices raises further concerns about measurement accuracy. Ambulatory blood pressure measurement (ABPM) may be used in addition to OBPM. It is recommended to diagnose white-coat and masked hypertension as well as nocturnal BP and dipping, which are the BP values most predictive for major adverse cardiac events. Nonetheless, ABPM is limited by its non-continuous nature and susceptibility to measurement artefacts. This leads to poor overall reproducibility of ABPM results, especially regarding clinical parameters such as BP variability or dipping patterns.ConclusionsCuff-based BP measurement, despite some limitations, is vital for cardiovascular health assessment in clinical practice. Given the wide range of methodological limitations, the paradigm's potential for improvement is not yet fully realized. There are impactful and easily incorporated opportunities for innovation regarding the enhancement of measurement accuracy and reliability as well as the clinical interpretation of the retrieved data. There is a clear need for continued research and technological advancement to improve BP measurement as the premier tool for cardiovascular disease detection and management. Accurate blood pressure measurement is crucial for diagnosing, monitoring, and treating hypertension and preventing cardiovascular diseases.Manual blood pressure monitoring is common but may not always be reliable due to the stress and time constraints in clinical settings. It also fails to detect white-coat and masked hypertension.Home blood pressure monitoring helps to identify white-coat and masked hypertension but depends on how well patients follow the measurement instructions. Many devices are not validated, raising concerns about their accuracy.Ambulatory blood pressure measurement may be used in addition to office blood pressure measurement because of its better reproducibility and higher predictive value. It is recommended to diagnose white-coat and masked hypertension as well as nocturnal BP and dipping. However, it and can be prone to errors, affecting the reliability of results like BP variability or night-time dipping patterns.Patient's posture, physical activity, and conditions like atrial fibrillation can influence BP readings.Automated BP devices often have limitations in detecting measurement artefacts, underscoring the need for technological improvements.Despite its limitations, cuff-based blood pressure measurement is essential in everyday clinical practice but has unlocked potential for improvement.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure
    Pucci, Giacomo
    Cheriyan, Joseph
    Hubsch, Annette
    Hickson, Stacey S.
    Gajendragadkar, Parag R.
    Watson, Timothy
    O'Sullivan, Michael
    Woodcock-Smith, Jean
    Schillaci, Giuseppe
    Wilkinson, Ian B.
    McEniery, Carmel M.
    JOURNAL OF HYPERTENSION, 2013, 31 (01) : 77 - 85
  • [22] Comparison of invasive and brachial cuff-based noninvasive measurements for the assessment of blood pressure amplification
    Atsushi Nakagomi
    Sho Okada
    Toshihiro Shoji
    Yoshio Kobayashi
    Hypertension Research, 2017, 40 : 237 - 242
  • [23] Comparison of invasive and brachial cuff-based noninvasive measurements for the assessment of blood pressure amplification
    Nakagomi, Atsushi
    Okada, Sho
    Shoji, Toshihiro
    Kobayashi, Yoshio
    HYPERTENSION RESEARCH, 2017, 40 (03) : 237 - 242
  • [24] Challenges in blood pressure measurement in children with obesity: focus on the cuff
    Evripidou, Kleo
    Chainoglou, Athanasia
    Kotsis, Vasilios
    Stabouli, Stella
    PEDIATRIC NEPHROLOGY, 2025,
  • [25] Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device
    Nachman, Dean
    Gepner, Yftach
    Goldstein, Nir
    Kabakov, Eli
    Ben Ishay, Arik
    Littman, Romi
    Azmon, Yuval
    Jaffe, Eli
    Eisenkraft, Arik
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [26] VALIDATION ASSESSMENT OF A CUFF-BASED CENTRAL BLOOD PRESSURE DEVICE ACCORDING TO ARTERY SOCIETY RECOMMENDATIONS
    Bui, Tan
    Picone, Dean
    Kosmala, Wojciech
    Kosowski, Michal
    Zachwyc, Jowita
    Pucci, Giacomo
    Schultz, Martin
    Black, Andrew
    Dwyer, Nathan
    Roberts-Thomson, Phillip
    Adams, Heath
    Curcio, Rosa
    Arrivi, Alessio
    Paleri, Sarang
    Sharman, James
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [27] Comparison between cuff-based and radial tonometry exercise-induced central blood pressure
    Morales-Acuna, Francisco
    Ratcliffe, Brycen
    Harrison, Caleb
    Crowe, Sierra
    Bockover, Evan
    Pawlak, Robert
    Gurovich, Alvaro N.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (04) : 901 - 911
  • [28] Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device
    Dean Nachman
    Yftach Gepner
    Nir Goldstein
    Eli Kabakov
    Arik Ben Ishay
    Romi Littman
    Yuval Azmon
    Eli Jaffe
    Arik Eisenkraft
    Scientific Reports, 10
  • [29] P1.01 Validation of a Brachial Cuff-Based Method for Assessing Central Blood Pressure
    T. Weber
    S. Wassertheurer
    C. Mayer
    B. Hametner
    J. Kropf
    B. Eber
    Artery Research, 2010, 4 (4) : 153 - 153
  • [30] CUFF-BASED AND INTRAARTERIAL BRACHIAL BLOOD PRESSURE MISMATCH AND ITS POTENTIAL IMPACT ON ANTIHYPERTENSIVE TREATMENT AND ESTIMATION OF AORTIC BLOOD PRESSURE
    Goupil, Remi
    Kowalski, Cedric
    Yang, Katie
    Charron, Thierry
    Doucet, Michel
    Hatem, Raja
    Kouz, Remi
    Palisaitis, Donald
    Schampaert, Erick
    Terriault, Paul
    Tessier, Pierre
    Agharazii, Mohsen
    JOURNAL OF HYPERTENSION, 2021, 39 : E409 - E409