Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification

被引:1
|
作者
Zhao, Yupeng [1 ]
Lerche, Mathilde Hauge [1 ]
Karlsson, Magnus [1 ]
Olin, Rie Beck [1 ]
Hansen, Esben Sovso Szocska [2 ]
Aastrup, Malene [2 ]
Redda, Mohsen [2 ]
Laustsen, Christoffer [2 ]
Hanson, Lars G. [1 ,3 ]
Ardenkjaer-Larsen, Jan Henrik [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[2] Aarhus Univ Hosp, MR Res Ctr, DK-8200 Aarhus, Denmark
[3] Copenhagen Univ Hosp Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, DK-2650 Hvidovre, Denmark
关键词
hyperpolarized MRI; coronary artery angiography; perfusion; myocardium;
D O I
10.3390/tomography10070084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Water freely diffuses across cell membranes, making it suitable for measuring absolute tissue perfusion. In this study, we introduce an imaging method for conducting coronary artery angiography and quantifying myocardial perfusion across the entire heart using hyperpolarized water. Methods: 1H was hyperpolarized using dissolution dynamic nuclear polarization (dDNP) with UV-generated radicals. Submillimeter resolution coronary artery images were acquired as 2D projections using a spoiled GRE (SPGRE) sequence gated on diastole. Dynamic perfusion images were obtained with a multi-slice SPGRE with diastole gating, covering the entire heart. Perfusion values were analyzed through histograms, and the most frequent estimated perfusion value (the mode of the distribution), was compared with the average values for 15O water PET from the literature. Results: A liquid state polarization of 10% at the time of the injection and a 30 s T1 in D2O TRIS buffer were measured. Both coronary artery and dynamic perfusion images exhibited good quality. The main and small coronary artery branches were well resolved. The most frequent estimated perfusion value is around 0.6 mL/g/min, which is lower than the average values obtained from the literature for 15O-water PET (around 1.1 and 1.5 mL/g/min). Conclusions: The study successfully demonstrated the feasibility of achieving high-resolution, motion-free coronary artery angiography and 3D whole-heart quantitative myocardial perfusion using hyperpolarized water.
引用
收藏
页码:1113 / 1122
页数:10
相关论文
共 50 条
  • [31] Incremental diagnostic value of whole-heart dynamic computed tomography perfusion imaging for detecting obstructive coronary artery disease
    Nishiyama, Hikaru
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Uetani, Teruyoshi
    Kido, Tomoyuki
    Ikeda, Shuntaro
    Miyagawa, Masao
    Mochizuki, Teruhito
    JOURNAL OF CARDIOLOGY, 2019, 73 (05) : 425 - 431
  • [32] Quantification of Absolute Myocardial Perfusion in Patients With Coronary Artery Disease
    Morton, Geraint
    Chiribiri, Amedeo
    Ishida, Masaki
    Hussain, Shazia T.
    Schuster, Andreas
    Indermuehle, Andreas
    Perera, Divaka
    Knuuti, Juhani
    Baker, Stacey
    Hedstroem, Erik
    Schleyer, Paul
    O'Doherty, Michael
    Barrington, Sally
    Nagel, Eike
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (16) : 1546 - 1555
  • [33] Prospective heart tracking for whole-heart magnetic resonance angiography
    Moghari, Mehdi H.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 759 - 765
  • [34] Long-term prognostic value of whole-heart coronary magnetic resonance angiography
    Satoshi Nakamura
    Masaki Ishida
    Kei Nakata
    Yasutaka Ichikawa
    Shinichi Takase
    Masafumi Takafuji
    Haruno Ito
    Shiro Nakamori
    Tairo Kurita
    Kaoru Dohi
    Hajime Sakuma
    Journal of Cardiovascular Magnetic Resonance, 23
  • [35] Long-term prognostic value of whole-heart coronary magnetic resonance angiography
    Nakamura, Satoshi
    Ishida, Masaki
    Nakata, Kei
    Ichikawa, Yasutaka
    Takase, Shinichi
    Takafuji, Masafumi
    Ito, Haruno
    Nakamori, Shiro
    Kurita, Tairo
    Dohi, Kaoru
    Sakuma, Hajime
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [36] 1127 Optimal scanning conditions for whole-heart coronary MR angiography in clinical practice
    Shigehide Kuhara
    Satoru Hasebe
    Seiko Mizuno
    Masatoshi Hyodo
    Hirofumi Anno
    Sachiko Ueoku
    Ayako Ninomiya
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [37] 2124 Whole-Heart Magnetic Resonance Coronary Angiography (WH MRCA) with visual feedback
    Shigehide Kuhara
    Tomohisa Okada
    Shotaro Kanao
    Ayako Ninomiya
    Saori Sato
    Toshikazu Kamae
    Kimio Goto
    Kaori Togashi
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [38] Quantitative low-dose rest and stress CT myocardial perfusion imaging with a whole-heart coverage scanner improves functional assessment of coronary artery disease
    Huang, I-Lun
    Wu, Ming-Ting
    Hu, Chin
    Mar, Guang-Yuan
    Lee, Ting-Yim
    So, Aaron
    IJC HEART & VASCULATURE, 2019, 24
  • [39] Diagnostic Accuracy of Three-Dimensional Whole-Heart Magnetic Resonance Angiography to Detect Coronary Artery Disease with Invasive Coronary Angiography as a Reference: A Meta-Analysis
    Yu, Shiqin
    Cui, Chen
    Lu, Minjie
    Zhao, Shihua
    CARDIOVASCULAR INNOVATIONS AND APPLICATIONS, 2020, 4 (03) : 173 - 184
  • [40] A WHOLE-HEART MODEL INCORPORATING MYOCARDIAL ANISOTROPY
    LORANGE, M
    GULRAJANI, RM
    DEGUISE, J
    FORTIER, P
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 195 - 195