Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification

被引:1
|
作者
Zhao, Yupeng [1 ]
Lerche, Mathilde Hauge [1 ]
Karlsson, Magnus [1 ]
Olin, Rie Beck [1 ]
Hansen, Esben Sovso Szocska [2 ]
Aastrup, Malene [2 ]
Redda, Mohsen [2 ]
Laustsen, Christoffer [2 ]
Hanson, Lars G. [1 ,3 ]
Ardenkjaer-Larsen, Jan Henrik [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
[2] Aarhus Univ Hosp, MR Res Ctr, DK-8200 Aarhus, Denmark
[3] Copenhagen Univ Hosp Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, DK-2650 Hvidovre, Denmark
关键词
hyperpolarized MRI; coronary artery angiography; perfusion; myocardium;
D O I
10.3390/tomography10070084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Water freely diffuses across cell membranes, making it suitable for measuring absolute tissue perfusion. In this study, we introduce an imaging method for conducting coronary artery angiography and quantifying myocardial perfusion across the entire heart using hyperpolarized water. Methods: 1H was hyperpolarized using dissolution dynamic nuclear polarization (dDNP) with UV-generated radicals. Submillimeter resolution coronary artery images were acquired as 2D projections using a spoiled GRE (SPGRE) sequence gated on diastole. Dynamic perfusion images were obtained with a multi-slice SPGRE with diastole gating, covering the entire heart. Perfusion values were analyzed through histograms, and the most frequent estimated perfusion value (the mode of the distribution), was compared with the average values for 15O water PET from the literature. Results: A liquid state polarization of 10% at the time of the injection and a 30 s T1 in D2O TRIS buffer were measured. Both coronary artery and dynamic perfusion images exhibited good quality. The main and small coronary artery branches were well resolved. The most frequent estimated perfusion value is around 0.6 mL/g/min, which is lower than the average values obtained from the literature for 15O-water PET (around 1.1 and 1.5 mL/g/min). Conclusions: The study successfully demonstrated the feasibility of achieving high-resolution, motion-free coronary artery angiography and 3D whole-heart quantitative myocardial perfusion using hyperpolarized water.
引用
收藏
页码:1113 / 1122
页数:10
相关论文
共 50 条
  • [21] Acute myocardial infarction in a patient with anomalous origin of the right coronary artery: Depiction at whole-heart coronary magnetic resonance angiography and delayed-enhanced imaging
    Ishii, Mitsuru
    Sato, Yuichi
    Matsumoto, Naoya
    Kunimasa, Taeko
    Tani, Shigemasa
    Tachibana, Eizo
    Kikushima, Kimio
    Nagao, Ken
    Saito, Satoshi
    Hirayama, Atsushi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 131 (01) : E22 - E24
  • [22] Three-Dimensional Heart Locator for Whole-Heart Coronary Magnetic Resonance Angiography
    Moghari, Mehdi H.
    Roujol, Sebastien
    Henningsson, Markus
    Kissinger, Kraig V.
    Annese, David
    Nezafat, Reza
    Manning, Warren J.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2118 - 2126
  • [23] Noninvasive Detection of Coronary Artery Stenoses with Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3.0 T
    Chen, Zhiyong
    Duan, Qing
    Xue, Xunjing
    Chen, Lianglong
    Ye, Wenbin
    Jin, Lixin
    Sun, Bin
    CARDIOLOGY, 2010, 117 (04) : 284 - 290
  • [24] 3.0T Contrast-enhanced whole-heart coronary magnetic resonance angiography for simultaneous coronary artery angiography and myocardial viability in chronic myocardial infarction A single-center preliminary study
    Chen, Zhiyong
    Sun, Bin
    Duan, Qing
    Xue, Yunjing
    Chen, Lianglong
    MEDICINE, 2018, 97 (45)
  • [25] Automated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T
    D Dey
    A Schuhbaeck
    Q Yang
    Z Fan
    G Germano
    S Achenbach
    D Li
    P Slomka
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [26] Whole-heart coronary magnetic resonance angiography with MS-325 (Gadofosveset)
    Kelle, Sebastian
    Thouet, Thomas
    Tangcharoen, Tarinee
    Nassenstein, Kai
    Chiribiri, Amedeo
    Paetsch, Ingo
    Schnackenburg, Bernhard
    Barkhausen, Joerg
    Fleck, Eckart
    Nagel, Eike
    MEDICAL SCIENCE MONITOR, 2007, 13 (11): : CR469 - CR474
  • [27] Clinical evaluation of automatic whole-heart and coronary-artery segmentation
    Marcel Breeuwer
    Pierre Ermes
    Bernhard Gerber
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [28] Accelerated whole-heart 3D CSPAMM for myocardial motion quantification
    Rutz, Andrea K.
    Ryf, Salome
    Plein, Sven
    Boesiger, Peter
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 755 - 763
  • [29] Multicenter evaluation of dynamic three-dimensional whole-heart myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve
    Robert Manka
    Rolf Gebker
    Lukas Wissmann
    Roy Jogiya
    Manish Motwani
    Michael Frick
    Sebastian D Reinartz
    Bernhard Schnackenburg
    Eike Nagel
    Sven Plein
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [30] The promise of whole-heart coronary MRI
    Hauser T.H.
    Manning W.J.
    Current Cardiology Reports, 2008, 10 (1) : 46 - 50