Seismic retrofitting of URM masonry piers with helical steel reinforcement

被引:1
|
作者
Cholostiakow, Szymon [1 ]
Mckinley, Brett [2 ,3 ]
Mergos, Panagiotis [3 ]
Hall, Christian [4 ]
Kappos, Andreas [5 ]
Ayoub, Ashraf [3 ]
机构
[1] Univ Thessaly, Volos, Greece
[2] Univ Cent Lancashire, Preston, England
[3] City Univ London, London, England
[4] Target Fixings Ltd, Unit 3,Red Shute Hill Ind, Hermitage RG18 9QL, Est, England
[5] Khalifa Univ Sci & Technol, Abu Dhabi, U Arab Emirates
基金
“创新英国”项目;
关键词
Helical stainless-steel reinforcement; Twisted bars; Seismic retrofitting; Masonry; In-plane damage; Shear; SHEAR BEHAVIOR; WALLS;
D O I
10.1016/j.conbuildmat.2024.136499
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Past earthquakes revealed that the brittle nature of unreinforced masonry (URM) structural walls often leads to extensive cacking and shear damage, which can seriously affect the structural integrity and thus compromise the safety of the entire building. Hence, finding an effective seismic retrofitting solution that can increase the safety of existing masonry building stock is of great importance. This paper explores the potential of alternative seismic retrofitting solutions for URM masonry walls- near-surface mounted austenitic stainless-steel helical bars. Being cold rolled from a plain round wire and subsequently tensioned through a free-twisting process, such a reinforcement can not only offer high durability, but also superior mechanical and bond properties, as well as effective redistribution of loads through the retrofitted masonry. In addition, the relatively high flexibility of the bars allows them to be mounted continuously along the joints of the wall, leaving the aesthetic of the retrofitted masonry intact. A total of nine single-leaf clay brick walls were tested under cyclic displacement reversals to examine the seismic performance of the reinforcement in terms of increasing in-plane shear capacity and ductility. Test specimens comprised cantilever walls with various retrofitting patterns, including flexural and shear helical reinforcements installed in the mortar joints or into the vertical slots cut into the masonry. The results showed considerable improvements in the ductility and energy dissipation of the walls after the retrofitting. For most of the retrofitted walls the value of q factors exceeded 4.0, which is greater than the typical q factors for reinforced masonry, thus indicating that large increases in ductility were achieved. The paper highlights the potential of helical stainless-steel bars as a seismic retrofitting reinforcement capable of preserving the structural integrity of masonry structures at increasing displacement demands without affecting the aesthetic of the surface of the walls.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Seismic retrofitting of rubble masonry tunnel: evaluation of steel fiber shotcrete or inner concrete lining alternatives
    Ako Daraei
    Hunar Farid Hama Ali
    Diyar Nasih Qader
    Shokrollah Zare
    Arabian Journal of Geosciences, 2022, 15 (11)
  • [32] Seismic retrofitting of non-engineered masonry in rural Nepal
    Macabuag, Joshua
    Guragain, Ramesh
    Bhattacharya, Subhamoy
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (06) : 273 - 286
  • [33] Seismic assessment and retrofitting measures of a historic stone masonry bridge
    Rovithis, Emmanouil N.
    Pitilakis, Kyriazis D.
    EARTHQUAKES AND STRUCTURES, 2016, 10 (03) : 645 - 667
  • [34] Seismic retrofitting of the historical masonry structures using numerical approach
    Akcay, Cemil
    Bozkurt, Tank Serhat
    Sayin, Baris
    Yildizlar, Baris
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 113 : 752 - 763
  • [35] Seismic Vulnerability Mitigation of a Masonry Church by means of CFRP Retrofitting
    Milani, Gabriele
    Shehu, Rafael
    Valente, Marco
    18TH INTERNATIONAL CONFERENCE ON REHABILITATION AND RECONSTRUCTION OF BUILDINGS (CRRB), 2017, 195 : 40 - 47
  • [36] Seismic Performance of Unreinforced Masonry Walls with Various Retrofitting Methods
    Kim, Seung-Hee
    Park, Sang-Hyun
    Pham, Huu Hiep
    Lee, Seung-Jae
    Dinh, Ngoc Hieu
    Choi, Kyoung-Kyu
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024,
  • [37] MANUAL FOR SEISMIC RETROFITTING OF THE EXISTING MASONRY BUILDINGS TECHNIQUES FOR THE REPAIR AND STRENGTHENING OF THE MASONRY BUILDINGS
    Pletenac, Tomislav
    PROSTOR, 2020, 28 (01): : 192 - 193
  • [38] Seismic evaluation and retrofitting of the structures of the Sadaghiani masonry historical complex
    Kheirollahi, Mohammad
    Mirzaei, Moein
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [39] Analysis and seismic retrofitting of unreinforced masonry building: a case study
    Aziz I.
    Ahsan R.
    Sakib M.S.
    Aziz S.
    Islam M.A.
    Ansary M.A.
    Asian Journal of Civil Engineering, 2021, 22 (3) : 443 - 460
  • [40] Seismic behavior of full-scale wall piers with high-strength steel reinforcement
    Yang, Cancan
    Chou, Yu-Chen
    Hung, Chung-Chan
    ENGINEERING STRUCTURES, 2022, 256