Seismic retrofitting of URM masonry piers with helical steel reinforcement

被引:1
|
作者
Cholostiakow, Szymon [1 ]
Mckinley, Brett [2 ,3 ]
Mergos, Panagiotis [3 ]
Hall, Christian [4 ]
Kappos, Andreas [5 ]
Ayoub, Ashraf [3 ]
机构
[1] Univ Thessaly, Volos, Greece
[2] Univ Cent Lancashire, Preston, England
[3] City Univ London, London, England
[4] Target Fixings Ltd, Unit 3,Red Shute Hill Ind, Hermitage RG18 9QL, Est, England
[5] Khalifa Univ Sci & Technol, Abu Dhabi, U Arab Emirates
基金
“创新英国”项目;
关键词
Helical stainless-steel reinforcement; Twisted bars; Seismic retrofitting; Masonry; In-plane damage; Shear; SHEAR BEHAVIOR; WALLS;
D O I
10.1016/j.conbuildmat.2024.136499
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Past earthquakes revealed that the brittle nature of unreinforced masonry (URM) structural walls often leads to extensive cacking and shear damage, which can seriously affect the structural integrity and thus compromise the safety of the entire building. Hence, finding an effective seismic retrofitting solution that can increase the safety of existing masonry building stock is of great importance. This paper explores the potential of alternative seismic retrofitting solutions for URM masonry walls- near-surface mounted austenitic stainless-steel helical bars. Being cold rolled from a plain round wire and subsequently tensioned through a free-twisting process, such a reinforcement can not only offer high durability, but also superior mechanical and bond properties, as well as effective redistribution of loads through the retrofitted masonry. In addition, the relatively high flexibility of the bars allows them to be mounted continuously along the joints of the wall, leaving the aesthetic of the retrofitted masonry intact. A total of nine single-leaf clay brick walls were tested under cyclic displacement reversals to examine the seismic performance of the reinforcement in terms of increasing in-plane shear capacity and ductility. Test specimens comprised cantilever walls with various retrofitting patterns, including flexural and shear helical reinforcements installed in the mortar joints or into the vertical slots cut into the masonry. The results showed considerable improvements in the ductility and energy dissipation of the walls after the retrofitting. For most of the retrofitted walls the value of q factors exceeded 4.0, which is greater than the typical q factors for reinforced masonry, thus indicating that large increases in ductility were achieved. The paper highlights the potential of helical stainless-steel bars as a seismic retrofitting reinforcement capable of preserving the structural integrity of masonry structures at increasing displacement demands without affecting the aesthetic of the surface of the walls.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Energy and seismic drawbacks of masonry: a unified retrofitting solution
    Longo F.
    Cascardi A.
    Lassandro P.
    Aiello M.A.
    Journal of Building Pathology and Rehabilitation, 2021, 6 (1)
  • [22] Innovative Method for Seismic and Energy Retrofitting of Masonry Buildings
    Facconi, Luca
    Lucchini, Sara S.
    Minelli, Fausto
    Grassi, Benedetta
    Pilotelli, Mariagrazia
    Plizzari, Giovanni A.
    SUSTAINABILITY, 2021, 13 (11)
  • [23] Review of Methods for Seismic Strengthening of Masonry Piers and Walls
    Hafner, Ivan
    Kisicek, Tomislav
    Gams, Matija
    BUILDINGS, 2023, 13 (06)
  • [24] Seismic retrofitting of unreinforced masonry buildings - a literature review
    Chuang, S.
    Zhuge, Y.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2005, 6 (01) : 25 - 36
  • [25] An experimental study for seismic reinforcement method on existing cylindrical steel piers by welded rectangular steel plates
    Chu, KZ
    Sakurai, T
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 763 - 770
  • [26] Seismic retrofitting methods for the jack arch masonry slabs
    Maheri, Mahmoud R.
    Pourfallah, S.
    Azarm, R.
    ENGINEERING STRUCTURES, 2012, 36 : 49 - 60
  • [27] Reinforcement of Masonry Vaults for Seismic Loading
    Sarkisian, M.
    Mathias, N.
    Beghini, A.
    Walker, S.
    Vaulot, L.
    STRUCTURES CONGRESS 2018: BUILDINGS AND DISASTER MANAGEMENT, 2019, : 302 - 316
  • [28] A kinematic limit analysis approach for seismic retrofitting of masonry towers through steel tie-rods
    Milani, Gabriele
    Shehu, Rafael
    Valente, Marco
    ENGINEERING STRUCTURES, 2018, 160 : 212 - 228
  • [29] Seismic Retrofitting of Structures by Steel Bracings
    Navya, G.
    Agarwal, Pankaj
    INTERNATIONAL CONFERENCE ON VIBRATION PROBLEMS 2015, 2016, 144 : 1364 - 1372
  • [30] Seismic performance and retrofitting of steel bearings
    Mander, J.B.
    Kim, D.K.
    Chen, S.S.
    American Concrete Institute, ACI Special Publication, 1996, SP-164 : 323 - 336