Biomechanical Study of Porcine Osteoporotic Vertebral Compression Fracture Model Strengthened by Trajectory-Adjustable Bone Cement Filling Device

被引:0
|
作者
Cao, Wenbing [1 ]
Li, Dapeng [1 ]
Chen, Honggu [1 ]
Luo, Zhenyu [1 ]
Zhang, Xing [2 ]
Li, Yongchao [3 ]
机构
[1] Jiangsu Univ, Dept Orthoped, Affiliated Hosp, Zhenjiang, Jiangsu, Peoples R China
[2] Yangzhou Jiangdu Peoples Hosp, Dept Orthoped, Yangzhou, Jiangsu, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 3, Dept Orthoped, Beijing, Peoples R China
关键词
Biomechanics; Bone cement distribution; Osteoporotic vertebral compression fracture; Porcine vertebrae; Trajectory-adjustable; Vertebroplasty; FINITE-ELEMENT-ANALYSIS; PERCUTANEOUS KYPHOPLASTY; VOLUME; VERTEBROPLASTY;
D O I
10.1016/J.wNEU.2024.02.019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To establish a porcine osteoporotic vertebral compression fracture model and compare the impact of unilateral vertebroplasty using trajectory-adjustable bone cement filling device to traditional surgical tools on vertebral biomechanics. METHODS: Twenty-four fresh adult porcine vertebrae were used to establish an osteoporotic vertebral compression fracture model. The specimens were divided into 4 groups (A, B, C, and D), each consisting of 6 vertebrae. Group A served as the control group without vertebral augmentation (percutaneous vertebroplasty [PVP]). Patients in Group B underwent unilateral PVP using conventional surgical tools, while patients in Group C underwent bilateral PVP using the same tools. In Group D, patients underwent unilateral PVP with a trajectory-adjustable bone cement filling device. Postoperative X-ray examinations were performed to assess cement distribution and leakage. The compressive stiffness and strength of each spinal unit were evaluated using an electronic mechanical testing machine. RESULTS: In Groups B, C, and D, the percentages of total cement distribution area were 32.83 +/- 3.64%, 45.73 +/- 2.27%, and 47.43 +/- 3.51%, respectively. The values were significantly greater in Groups C and D than in Group B (P< P < 0.05), but there was no significant difference between Groups C and D (P P > 0.05). The stiffness after vertebral augmentation in Groups B, C, and D was 1.04 +/- 0.23 kN/mm, 1.11 +/- 0.16 KN/mm, and 1.15 +/- 0.13 KN/mm, respectively, which were significantly greater than that in Group A (0.46 +/- 0.06 kN/mm; P < 0.05). The ultimate compressive strengths in Groups B, C, and D were 2.53 +/- 0.21 MPa, 4.09 +/- 0.30 MPa, and 3.99 +/- 0.29 MPa, respectively, all surpassing Group A's strength of 1.41 +/- 0.31 MPa. Additionally, both Groups C and D demonstrated significantly greater ultimate compressive strengths than Group B did (P P < 0.05). CONCLUSIONS: A trajectory-adjustable bone cement filling device was proven to be an effective approach for unilateral vertebroplasty, restoring the biomechanical properties of fractured vertebrae. Compared to traditional surgical tools, this approach is superior to unilateral puncture and yields outcomes comparable to those of bilateral puncture. Additionally, the device ensures a centrally symmetrical distribution pattern of bone cement, leading to improved morphology.
引用
收藏
页码:E357 / E366
页数:10
相关论文
共 50 条
  • [31] Comparison of the Clinical Efficacy and Bone Cement Distribution Difference Between Kummell's Disease and Osteoporotic Vertebral Compression Fracture After Percutaneous Kyphoplasty
    Ning, Yuzhi
    Li, Ziyu
    Huang, Jiahu
    Xu, Shuang
    Wang, Qing
    Yan, Jiyuan
    Wang, Song
    PAIN PHYSICIAN, 2024, 27 (03) : E327 - E336
  • [32] Preoperative planning of compact zone trajectory is necessary in treating osteoporotic vertebral compression fracture with endplate involvement: A prospective randomized controlled study
    Hung, Pei-, I
    Chou, Po-Hsin
    Yao, Yu-Cheng
    Chen, Kuan-Jung
    Lin, Hsi-Hsien
    Wang, Shih-Tien
    Chang, Ming-Chau
    Liu, Chien-Lin
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (11) : 985 - 990
  • [33] Safety and Efficacy of Bone Cement (Spinofill®) for Verte-broplasty in Patients with Osteoporotic Compression Fracture : A Preliminary Prospective Study
    Park, Han Byeol
    Son, Seong
    Jung, Jong Myung
    Lee, Sang Gu
    Yoo, Byung Rhae
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2022, 65 (05) : 730 - 740
  • [34] Osteoporotic vertebral compression fracture augmentation by injectable partly resorbable ceramic bone substitute (Cerament™|SPINESUPPORT): a prospective nonrandomized study
    Masala, Salvatore
    Nano, Giovanni
    Marcia, Stefano
    Muto, Mario
    Fucci, Francesco P. M.
    Simonetti, Giovanni
    NEURORADIOLOGY, 2012, 54 (11) : 1245 - 1251
  • [35] Osteoporotic vertebral compression fracture augmentation by injectable partly resorbable ceramic bone substitute (Cerament™|SPINESUPPORT): a prospective nonrandomized study
    Salvatore Masala
    Giovanni Nano
    Stefano Marcia
    Mario Muto
    Francesco P. M. Fucci
    Giovanni Simonetti
    Neuroradiology, 2012, 54 : 1245 - 1251
  • [36] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    Hoegel, F.
    Mair, S.
    Eberle, S.
    Weninger, P.
    von Oldenburg, G.
    Augat, P.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 51 - 57
  • [37] Distal radius fracture fixation with volar locking plates and additional bone augmentation in osteoporotic bone: a biomechanical study in a cadaveric model
    F. Högel
    S. Mair
    S. Eberle
    P. Weninger
    G. von Oldenburg
    P. Augat
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 51 - 57
  • [38] A Retrospective Study of 91 Patients Treated with Percutaneous Kyphoplasty for Mild Osteoporotic Vertebral Compression Fractures and a New Evaluation Scale of Shape and Filling Effect of Cement
    Bian, Chong
    Gu, Huijie
    Chen, Guangnan
    Cheng, Xiangyang
    Huang, Zhongyue
    Xu, Jun
    Yin, Xiaofan
    WORLD NEUROSURGERY, 2024, 186 : E134 - E141
  • [39] BIOMECHANICAL EVALUATION OF LOW-MODULUS BONE CEMENT FOR ENHANCING APPLICABILITY IN VERTEBROPLASTY - AN EXPERIMENTAL STUDY IN PORCINE MODEL
    Liu, Mu-Yi
    Lai, Po-Liang
    Tai, Ching-Lung
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2018, 30 (01):
  • [40] Antegrade anterior column acetabulum fracture fixation with cannulated compression headless screws-A biomechanical study on standardized osteoporotic artificial bone
    Berk, Till
    Zderic, Ivan
    Schwarzenberg, Peter
    Pastor, Torsten
    Drenchev, Ludmil
    Skulev, Hristo Kostov
    Richards, Geoff
    Hierholzer, Christian
    Halvachizadeh, Sascha
    Pape, Hans-Christoph
    Gueorguiev, Boyko
    PLOS ONE, 2024, 19 (06):