Biomechanical Study of Porcine Osteoporotic Vertebral Compression Fracture Model Strengthened by Trajectory-Adjustable Bone Cement Filling Device

被引:0
|
作者
Cao, Wenbing [1 ]
Li, Dapeng [1 ]
Chen, Honggu [1 ]
Luo, Zhenyu [1 ]
Zhang, Xing [2 ]
Li, Yongchao [3 ]
机构
[1] Jiangsu Univ, Dept Orthoped, Affiliated Hosp, Zhenjiang, Jiangsu, Peoples R China
[2] Yangzhou Jiangdu Peoples Hosp, Dept Orthoped, Yangzhou, Jiangsu, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 3, Dept Orthoped, Beijing, Peoples R China
关键词
Biomechanics; Bone cement distribution; Osteoporotic vertebral compression fracture; Porcine vertebrae; Trajectory-adjustable; Vertebroplasty; FINITE-ELEMENT-ANALYSIS; PERCUTANEOUS KYPHOPLASTY; VOLUME; VERTEBROPLASTY;
D O I
10.1016/J.wNEU.2024.02.019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To establish a porcine osteoporotic vertebral compression fracture model and compare the impact of unilateral vertebroplasty using trajectory-adjustable bone cement filling device to traditional surgical tools on vertebral biomechanics. METHODS: Twenty-four fresh adult porcine vertebrae were used to establish an osteoporotic vertebral compression fracture model. The specimens were divided into 4 groups (A, B, C, and D), each consisting of 6 vertebrae. Group A served as the control group without vertebral augmentation (percutaneous vertebroplasty [PVP]). Patients in Group B underwent unilateral PVP using conventional surgical tools, while patients in Group C underwent bilateral PVP using the same tools. In Group D, patients underwent unilateral PVP with a trajectory-adjustable bone cement filling device. Postoperative X-ray examinations were performed to assess cement distribution and leakage. The compressive stiffness and strength of each spinal unit were evaluated using an electronic mechanical testing machine. RESULTS: In Groups B, C, and D, the percentages of total cement distribution area were 32.83 +/- 3.64%, 45.73 +/- 2.27%, and 47.43 +/- 3.51%, respectively. The values were significantly greater in Groups C and D than in Group B (P< P < 0.05), but there was no significant difference between Groups C and D (P P > 0.05). The stiffness after vertebral augmentation in Groups B, C, and D was 1.04 +/- 0.23 kN/mm, 1.11 +/- 0.16 KN/mm, and 1.15 +/- 0.13 KN/mm, respectively, which were significantly greater than that in Group A (0.46 +/- 0.06 kN/mm; P < 0.05). The ultimate compressive strengths in Groups B, C, and D were 2.53 +/- 0.21 MPa, 4.09 +/- 0.30 MPa, and 3.99 +/- 0.29 MPa, respectively, all surpassing Group A's strength of 1.41 +/- 0.31 MPa. Additionally, both Groups C and D demonstrated significantly greater ultimate compressive strengths than Group B did (P P < 0.05). CONCLUSIONS: A trajectory-adjustable bone cement filling device was proven to be an effective approach for unilateral vertebroplasty, restoring the biomechanical properties of fractured vertebrae. Compared to traditional surgical tools, this approach is superior to unilateral puncture and yields outcomes comparable to those of bilateral puncture. Additionally, the device ensures a centrally symmetrical distribution pattern of bone cement, leading to improved morphology.
引用
收藏
页码:E357 / E366
页数:10
相关论文
共 50 条
  • [21] Effect of PVP with a Mesh-Hold bone-filling mesh bag and different viscosities of bone cement in the treatment of osteoporotic vertebral compression fractures
    Gao, Yusheng
    Huo, Mingchang
    Fan, Xuehui
    Zhou, Xiaodong
    Luan, Junwei
    Dong, Zhiyong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (07): : 5006 - 5012
  • [22] Comparing percutaneous kyphoplasty with bone cement-augmented pedicle screw fixation in severe thoracolumbar osteoporotic vertebral compression fracture
    Han, Fei
    Chen, Haidan
    Zhao, Hongwei
    ASIAN JOURNAL OF SURGERY, 2024, 47 (01) : 558 - 559
  • [23] Biomechanical Analysis of Cortical Bone Trajectory Screw Versus Bone Cement Screw for Fixation in Porcine Spinal Low Bone Mass Model
    Li, Yifan
    Wang, Silian
    Zhu, Zhenbiao
    Chen, Liwei
    Shi, Zhangpeng
    Ye, Xiaojian
    Xu, Wei
    Li, Zhikun
    CLINICAL SPINE SURGERY, 2023, 36 (04): : E145 - E152
  • [24] Biomechanical evaluation of kyphoplasty with calcium phosphate cement in a 2-functional spinal unit vertebral compression fracture model
    Khanna, A. Jay
    Lee, Samuel
    Villarraga, Marta
    Gimbel, Jonathan
    Steffey, Duane
    Schwardt, Jeffrey
    SPINE JOURNAL, 2008, 8 (05): : 770 - 777
  • [25] Mineralized Collagen Modified Polymethyl Methacrylate Bone Cement for Osteoporotic Compression Vertebral Fracture at 1-Year Follow-up
    Zhu, Jinjin
    Zhang, Kai
    Luo, Kefeng
    Qiu, Zhiye
    Yang, Shuhui
    Cui, Fuzhai
    Weng, Xisheng
    Jiang, Guogiang
    SPINE, 2019, 44 (12) : 827 - 838
  • [26] Effect of different bone cement distributions in percutaneous kyphoplasty on clinical outcomes for osteoporotic vertebral compression fractures: A retrospective study
    Song, Qichun
    Zhao, Yan
    Li, Dong
    Liu, Zhaoying
    Zhang, Yuankai
    Shang, Donglong
    Geng, Zilong
    Shi, Zhibin
    Fan, Li-Hong
    MEDICINE, 2023, 102 (12) : E33309
  • [27] Height and volume restoration in osteoporotic vertebral compression fractures: a biomechanical comparison of standard balloon kyphoplasty versus Tektona® in a cadaveric fracture model
    Krueger, Antonio
    Baeumlein, Martin
    Knauf, Tom
    Pascal-Moussellard, Hugues
    Ruchholtz, Steffen
    Oberkircher, Ludwig
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [28] Height and volume restoration in osteoporotic vertebral compression fractures: a biomechanical comparison of standard balloon kyphoplasty versus Tektona® in a cadaveric fracture model
    Antonio Krüger
    Martin Bäumlein
    Tom Knauf
    Hugues Pascal-Moussellard
    Steffen Ruchholtz
    Ludwig Oberkircher
    BMC Musculoskeletal Disorders, 22
  • [29] Biomechanical study of olecranon plate fixation in comminuted osteoporotic fracture model: locking compression plates versus dynamic compression plates
    Shakir, Irshad
    Israel, Heidi
    Cannada, Lisa K.
    Bledsoe, Gary
    CURRENT ORTHOPAEDIC PRACTICE, 2018, 29 (02): : 167 - 172
  • [30] Using the cortical bone trajectory screw technique with vertebral column resection to treat an osteoporotic compression fracture in progressive thoracolumbar hyperkyphosis: A case report
    Chao, Chia-Hung
    Hsieh, Cheng-Yang
    Su, Yu-Feng
    Kwan, Aij-Lie
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2019, 15 : 98 - 100