Edible Bite Force Sensor: A Novel Approach to Measuring Bite Force in Biomedical and Dental Applications

被引:0
|
作者
Milic, Lazar [1 ]
Kojic, Sanja [1 ]
Qureshi, Saima [1 ]
Simic, Mitar [1 ]
Duval, Raphael Georges [2 ]
Petrovic, Bojan [3 ]
Stojanovic, Goran M. [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Novi Sad, Serbia
[2] Nat Res & Dev, Barcelona, Spain
[3] Univ Novi Sad, Fac Med, Dept Dent, Novi Sad, Serbia
来源
MEDICAL SCIENCE MONITOR | 2024年 / 30卷
关键词
Biocompatible Materials; Bite Force; Edible Films; Hydrogel Film; Oral Health; HYDROGEL; DEVICE;
D O I
10.12659/MSM.944050
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Measurement of bite force plays a crucial role in assessment of the masticatory system. With a growing interest in detecting occlusal irregularities, bite force sensors have garnered attention in the biomedical field. This study aimed to introduce a hydrogel bite force sensor, based on hydroxyethyl-cellulose-fructose-water (HEC-F-water), for premolar and molar teeth, and to evaluate it using optical profilometry, infrared spectroscopy (FTIR), and Instron Tension testing system, with 2.5 cm (1 inch) margins at top, bottom, right, and left. Material/Methods: We fabricated 20 HEC-F-water hydrogel samples sized with surface of 1x1 cm, with 2 different widths - 1 mm and 5 mm. The samples were characterized using optical profilometry and FTIR and their electrical characteristics were determined using an impedance analyzer. Aluminum (Al) electrodes, fabricated using Cutting Plotter, were used to form a HEC-F-water-based transducer, which was used for bite force sensing. The Instron tensile testing system was employed, utilizing 3D printed models of the upper and lower jaw, to simulate biting. Forces in the range between 40 N and 540 N were exerted upon the transducer, and the output change in the electrical signal was measured. Results: The study determined the transfer function between bite force and capacitance. The fabricated sensor exhibited a sensitivity of 3.98 pF/N, an input range of 500 N, output range of 2 nF, and accuracy of 95.9%. Conclusions: This study introduces an edible bite force sensor employing an edible hydrogel as a dielectric, presenting a novel avenue in the development of edible sensorics in dentistry.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Bite force and pattern measurements for dental pain assessment in the rat
    Khan, Junad
    Benoliel, Rafael
    Herzberg, Uri
    Mannes, Andrew J.
    Caudle, Robert M.
    Young, Andrew
    Eliav, Eli
    NEUROSCIENCE LETTERS, 2008, 447 (2-3) : 175 - 178
  • [22] BITE FORCE AND DENTOFACIAL MORPHOLOGY IN MEN WITH SEVERE DENTAL ATTRITION
    WALTIMO, A
    NYSTROM, M
    KONONEN, M
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1994, 102 (02): : 92 - 96
  • [23] THE EFFECTS OF DENTAL CONDITION ON HAND STRENGTH AND MAXIMUM BITE FORCE
    CARLSSON, GE
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 1993, 11 (01): : 54 - 54
  • [24] A Novel Indigenously Developed Device to Measure Bite Force
    Ranjan, Madhu
    Singh, Bishnupati
    Chatterjee, Ujjal
    Tushar
    Sinha, Dharmendra K.
    Verma, Abhishek
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S550 - S553
  • [25] ON THE SENSE OF BITE FORCE IN MAN
    BROEKHUIJSEN, ML
    VANWILLIGEN, JD
    JOURNAL OF DENTAL RESEARCH, 1985, 64 (04) : 718 - 718
  • [26] BITE FORCE IN CHILDREN WITH BRUXISM
    LINDQVIST, B
    RINGQVIS.M
    ACTA ODONTOLOGICA SCANDINAVICA, 1973, 31 (04) : 255 - 259
  • [27] Bite force production in Kyphosidae
    Moran, C. J.
    Ferry, L. A.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2011, 51 : E96 - E96
  • [28] BITE FORCE DISCRIMINATION WITH OVERDENTURES
    WILLIAMS, WN
    RAU, CF
    JAGGERS, JH
    TURNER, GE
    GEIGER, LL
    JOURNAL OF DENTAL RESEARCH, 1986, 65 : 255 - 255
  • [29] INCISAL BITE FORCE - RESPONSE
    WOOD, DP
    ANGLE ORTHODONTIST, 1994, 64 (04) : 246 - 246
  • [30] BITE FORCE AND EXTENSIVE ATTRITION
    JOHANSSON, A
    HARALDSON, T
    CARLSSON, GE
    SWEDISH DENTAL JOURNAL, 1985, 9 (06) : 279 - 279