Edible Bite Force Sensor: A Novel Approach to Measuring Bite Force in Biomedical and Dental Applications

被引:0
|
作者
Milic, Lazar [1 ]
Kojic, Sanja [1 ]
Qureshi, Saima [1 ]
Simic, Mitar [1 ]
Duval, Raphael Georges [2 ]
Petrovic, Bojan [3 ]
Stojanovic, Goran M. [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Novi Sad, Serbia
[2] Nat Res & Dev, Barcelona, Spain
[3] Univ Novi Sad, Fac Med, Dept Dent, Novi Sad, Serbia
来源
MEDICAL SCIENCE MONITOR | 2024年 / 30卷
关键词
Biocompatible Materials; Bite Force; Edible Films; Hydrogel Film; Oral Health; HYDROGEL; DEVICE;
D O I
10.12659/MSM.944050
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Measurement of bite force plays a crucial role in assessment of the masticatory system. With a growing interest in detecting occlusal irregularities, bite force sensors have garnered attention in the biomedical field. This study aimed to introduce a hydrogel bite force sensor, based on hydroxyethyl-cellulose-fructose-water (HEC-F-water), for premolar and molar teeth, and to evaluate it using optical profilometry, infrared spectroscopy (FTIR), and Instron Tension testing system, with 2.5 cm (1 inch) margins at top, bottom, right, and left. Material/Methods: We fabricated 20 HEC-F-water hydrogel samples sized with surface of 1x1 cm, with 2 different widths - 1 mm and 5 mm. The samples were characterized using optical profilometry and FTIR and their electrical characteristics were determined using an impedance analyzer. Aluminum (Al) electrodes, fabricated using Cutting Plotter, were used to form a HEC-F-water-based transducer, which was used for bite force sensing. The Instron tensile testing system was employed, utilizing 3D printed models of the upper and lower jaw, to simulate biting. Forces in the range between 40 N and 540 N were exerted upon the transducer, and the output change in the electrical signal was measured. Results: The study determined the transfer function between bite force and capacitance. The fabricated sensor exhibited a sensitivity of 3.98 pF/N, an input range of 500 N, output range of 2 nF, and accuracy of 95.9%. Conclusions: This study introduces an edible bite force sensor employing an edible hydrogel as a dielectric, presenting a novel avenue in the development of edible sensorics in dentistry.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A novel sensor for bite force determinations
    Fernandes, CP
    Glantz, POJ
    Svensson, SA
    Bergmark, A
    DENTAL MATERIALS, 2003, 19 (02) : 118 - 126
  • [2] Measuring bite force in small mammals with a piezo-resistive sensor
    Freeman, Patricia W.
    Lemen, Cliff A.
    JOURNAL OF MAMMALOGY, 2008, 89 (02) : 513 - 517
  • [3] GNATHODYNAMOMETER DESIGNED FOR MEASURING TOTAL BITE FORCE
    WALSH, E
    GIBBS, C
    HIGGINS, A
    HOLBROOK, W
    JOURNAL OF DENTAL RESEARCH, 1980, 59 : 318 - 318
  • [4] Laboratory Validation of a Novel Indigenously Developed Bite Force Measuring Device
    Ranjan, Madhu
    Kumar, Surender
    Singh, Bishnupati
    Mahuli, Amit, V
    Jha, Awanindra K.
    Naik, Shantala R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [5] A novel approach to bite force measurements in a porcine model in vivo
    Bousdras, V. A.
    Cunningham, J. L.
    Ferguson-Pell, M.
    Bamber, M. A.
    Sindet-Pedersen, S.
    Blunn, G.
    Goodship, A. E.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (07) : 663 - 667
  • [6] Sensor for Bilateral Human Bite Force Measurements
    Suppelt, Sven
    Chadda, Romol
    Schaefer, Niklas
    Sader, Robert
    Kupnik, Mario
    2021 IEEE SENSORS, 2021,
  • [7] Capacitive-Type Pressure-Mapping Sensor for Measuring Bite Force
    Iwasaki, Masanori
    Maeda, Ichinosuke
    Kokubo, Yota
    Tanaka, Yoshitomo
    Ueno, Tetsuji
    Takahashi, Wataru
    Watanabe, Yutaka
    Hirano, Hirohiko
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (03)
  • [8] A NOVEL BITE FORCE RECORDER AND MAXIMAL ISOMETRIC BITE FORCE VALUES FOR HEALTHY-YOUNG ADULTS
    WALTIMO, A
    KONONEN, M
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1993, 101 (03): : 171 - 175
  • [9] Novel Low-Cost Sensor for Human Bite Force Measurement
    Fastier-Wooller, Jarred
    Hoang-Phuong Phan
    Dinh, Toan
    Tuan-Khoa Nguyen
    Cameron, Andrew
    Ochsner, Andreas
    Dao, Dzung Viet
    SENSORS, 2016, 16 (08)
  • [10] INCISAL BITE FORCE
    HOCKEL, JL