Speech Quality Perception in Unilateral Cochlear Implant Users With Single-Sided Deafness

被引:0
|
作者
Kelly, Scott [1 ]
Kuhlmey, Megan E. [1 ]
Despotidis, Meghan A. [1 ]
Alter, Isaac L. [1 ]
Hwa, Tiffany P. [2 ]
Chern, Alexander [3 ]
Lalwani, Anil K. [1 ,4 ]
机构
[1] Columbia Univ, Vagelos Coll Phys & Surg, New York Presbyterian, Dept Otolaryngol Head & Neck Surg,Irving Med Ctr, 180 Ft Washington Ave,HP8, New York, NY 10032 USA
[2] Univ Penn, Perelman Sch Med, Dept Otorhinolaryngol, Philadelphia, PA USA
[3] Johns Hopkins Univ, Dept Otolaryngol Head & Neck Surg, Baltimore, MD USA
[4] Columbia Univ, Dept Mech Engn, New York, NY 10032 USA
关键词
cochlear implant; CSQI; hearing loss; single-sided deafness; speech quality perception; MUSIC PERCEPTION; 2; EARS; IDENTIFICATION; RECOGNITION; VALIDATION; ABILITIES; FREQUENCY; APPRAISAL; PROSODY; FUSION;
D O I
10.1002/ohn.941
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective. Cochlear implant (CI) users frequently complain about speech quality perception (SQP). In patients undergoing cochlear implantation for single-sided deafness, there is concern that poor SQP from the implanted ear will negatively impact binaural (CI + normal hearing [NH]) SQP. In this study, we investigate if binaural SQP is measurably different than unimplanted NH alone. Study Design. Cross-sectional study. Setting. Tertiary care center. Methods. Fifteen unilateral CI users with NH in the contralateral ear completed the validated Columbia Speech Quality Instrument. This instrument consists of 9 audio clips rated across 14 specific speech qualities using a 10-point visual analog scale. SQP was assessed in 3 conditions: CI only, NH only, and CI + NH. Results. Median speech quality scores were worse in the CI only condition compared to the NH only (50.0 vs 72.6, P = .0003) and binaural (50.0 vs 71.0, P = .007) conditions. Median speech quality scores were not significantly different between the NH only and binaural conditions (72.6 vs 71, P = .8). Compared to NH, CI speech quality sounded less clear, less natural, and more mechanical. Conclusion. Compared to NH, SQP is poorer with a CI alone. However, in contrast to expectation, there is no significant difference between NH and binaural SQP. This suggests poorer CI speech perception does not negatively impact binaural SQP in patients undergoing cochlear implantation for single-sided deafness.
引用
收藏
页码:224 / 232
页数:9
相关论文
共 50 条
  • [21] Feasibility of Speech Testing Using Wireless Connection in Single-Sided Cochlear Implant Users
    Bae, Seong Hoon
    Jung, Youngrak
    Hur, Ji Hye
    Ha Kim, Jeong
    Choi, Jae Young
    JOURNAL OF AUDIOLOGY AND OTOLOGY, 2023, 27 (03): : 133 - 138
  • [22] Binaural Integration of Spectrally Degraded Speech in Adult Cochlear Implant Recipients with Single-Sided Deafness
    Speck, Iva
    Arndt, Susan
    Wiebe, Konstantin
    Zimmermann, Natalie
    Langner, Florian
    Rauch, Ann-Kathrin
    Aschendorff, Antje
    Wesarg, Thomas
    AUDIOLOGY AND NEUROTOLOGY, 2022, 27 (06) : 485 - 500
  • [23] Cochlear implantation and single-sided deafness
    Tokita, Joshua
    Dunn, Camille
    Hansen, Marlan R.
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2014, 22 (05): : 353 - 358
  • [24] Speech Perception in Noise After Cochlear Implantation for Single-Sided Deafness A Randomized Clinical Trial
    van Heteren, Jan A. A.
    Wendrich, Anne W.
    Peters, Jeroen P. M.
    Grolman, Wilko
    Stokroos, Robert J.
    Smit, Adriana L.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2025, 151 (03) : 211 - 219
  • [25] Cochlear Implants in Single-Sided Deafness
    Giardina, Christopher K.
    Formeister, Eric J.
    Adunka, Oliver F.
    CURRENT SURGERY REPORTS, 2014, 2 (12):
  • [26] Incapacitating unilateral tinnitus in single-sided deafness treated by cochlear implantation
    de Heyning, Paul Van
    Vermeire, Katrien
    Diebl, Martina
    Nopp, Peter
    Anderson, Ilona
    De Ridder, Dirk
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2008, 117 (09): : 645 - 652
  • [27] Speech Perception in Noise and Sound Localization for Cochlear Implant With Single-Sided Deafness Compared With Contralateral Routing of Signal Hearing Aids
    Oyamada, Shogo
    Takahashi, Masahiro
    Furutate, Sakiko
    Oka, Shinichirou
    Kubota, Eri
    Sakurai, Azusa
    Uekusa, Tomoko
    Watanabe, Kana
    Iwasaki, Satoshi
    OTOLOGY & NEUROTOLOGY, 2023, 44 (04) : 331 - 338
  • [28] Cochlear Implants in Single-Sided Deafness
    Christopher K. Giardina
    Eric J. Formeister
    Oliver F. Adunka
    Current Surgery Reports, 2 (12)
  • [29] Spatial Speech-in-Noise Performance in Bimodal and Single-Sided Deaf Cochlear Implant Users
    Williges, Ben
    Wesarg, Thomas
    Jung, Lorenz
    Geven, Leontien I.
    Radeloff, Andreas
    Juergens, Tim
    TRENDS IN HEARING, 2019, 23
  • [30] Single-Sided Deafness: Impact of Cochlear Implantation on Speech Perception in Complex Noise and on Auditory Localization Accuracy
    Doege, Julia
    Baumann, Uwe
    Weissgerber, Tobias
    Rader, Tobias
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : E563 - E569