Feasibility assessment of inspiration breath-hold motion management for tumor tracking during cone-beam computed tomography for setup and radiotherapy in Veterinary Medicine: A pilot study

被引:0
|
作者
Murakami, Keiko [1 ]
Rancilio, Nicholas [1 ]
Foster, Lisa [2 ]
机构
[1] Iowa State Univ, Coll Vet Med, Dept Vet Clin Sci, Ames, IA USA
[2] Iowa State Univ, Coll Vet Med, Lloyd Vet Med Ctr, Ames, IA USA
关键词
canine; feline; organ motion; radiation therapy; respiratory; BODY RADIATION-THERAPY; HEART BASE TUMORS;
D O I
10.1111/vru.13412
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Radiotherapy (RT) for lung or liver tumors can be challenging due to respiration-induced organ motion (RIOM). There are some methodological solutions to minimize RIOM. We explored a new approach to evaluate the feasibility and reproducibility of RIOM during RT with five total client-owned tumor-bearing animals using a remote-triggered breath-hold ventilator under general anesthesia during image acquisition and RT. There was one stereotactic body radiotherapy, one conventionally fractionated definitive intent, and three conventionally fractionated palliative intent RT cases. Based on repeated cone beam CT, there were no treatment table shifts required prior to initiating beam on. No clinically significant complications such as hypotension occurred during anesthesia. This technique appeared to be safe in this group of patients and was easily clinically implemented and highly reproducible. More complete follow-up data and larger studies are needed to evaluate clinical outcomes with this breath-hold ventilator technique in veterinary RT.
引用
收藏
页码:672 / 678
页数:7
相关论文
共 46 条
  • [31] Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: Results of a prospective study using cone-beam computed tomography
    Fatunase, Toyosi
    Wang, Zhiheng
    Yoo, Sua
    Hubbs, Jessica L.
    Prosnitz, Robert G.
    Yin, Fang-Fang
    Marks, Lawrence B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1025 - 1034
  • [32] Ramifications of Setup Margin Use During Frameless Stereotactic Radiosurgery/Therapy With Gamma Knife Icon Cone-Beam Computed Tomography (CBCT): A Dosimetric Study
    Duggar, William N.
    Morris, Bart
    He, Rui
    Yang, Claus Chunli
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
  • [33] Volumetric and morphometric analysis of the mastoid process for assessment of sexual dimorphism using cone-beam computed tomography: a pilot study for a new forensic approach
    Victória Emanuelle Ribeiro Celebrini
    Eduardo Murad Villoria
    Maria Augusta Visconti
    Andreia Cristina Breda de Souza
    Egyptian Journal of Forensic Sciences, 15 (1)
  • [34] Quantification of six-degree-of-freedom motion during beam delivery in spine stereotactic body radiotherapy using intra-irradiation cone-beam computed tomography imaging technique
    Iramina, Hiraku
    Nakamura, Mitsuhiro
    Nakamura, Kiyonao
    Fujimoto, Takahiro
    Mizowaki, Takashi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 110
  • [35] Serial kilovoltage cone-beam computed tomography imaging during intensity modulated radiotherapy for primary lung cancers: Observations of treatment effect and tumor-volume regression
    Newlin, H. E.
    Chvetsov, A.
    Rutenberg, M.
    Olivier, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S431 - S431
  • [36] Study to Compare the Effect of Different Registration Methods on Patient Setup Uncertainties in Cone-beam Computed Tomography during Volumetric Modulated Arc Therapy for Breast Cancer Patients
    Mohandass, P.
    Khanna, D.
    Kumar, T. Manoj
    Thiyagaraj, T.
    Saravanan, C.
    Bhalla, Narendra Kumar
    Puri, Abhishek
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 207 - 213
  • [37] Optimization of On-board 4D Cone Beam Computed Tomography for Pretreatment Patient Positioning Verification, Tumor Localization, and Motion Management Assessment
    Michaud, A. L.
    Hoffman, D.
    Daly, M. E.
    Semon, S.
    Benedict, S. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E583 - E583
  • [38] Cone beam computed tomography-based monitoring and management of target and organ motion during external beam radiotherapy in cervical cancer (vol 9, pg 14, 2019)
    Tetar, S. U.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 15 : 98 - 98
  • [39] Dosimetric consequences of tumor volume changes after kilovoltage cone-beam computed tomography for non-operative lung cancer during adaptive intensity-modulated radiotherapy or fractionated stereotactic radiotherapy
    Jian Hu
    Ximing Xu
    Guangjin Yuan
    Wei Ge
    Liming Xu
    Aihua Zhang
    Junjian Deng
    Oncology and Translational Medicine, 2015, 1 (05) : 195 - 200
  • [40] An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets; [Offline-Methode zur Evaluierung von Restbewegung des Diaphragmas unter inspiratorischem Atemanhalt von Cone-Beam-CT-Datensätzen]
    Blessing M.
    Hofmann J.
    Vogel L.
    Boda-Heggemann J.
    Lohr F.
    Wenz F.
    Stieler F.
    Simeonova-Chergou A.
    Strahlentherapie und Onkologie, 2018, 194 (9) : 855 - 860