Feasibility assessment of inspiration breath-hold motion management for tumor tracking during cone-beam computed tomography for setup and radiotherapy in Veterinary Medicine: A pilot study

被引:0
|
作者
Murakami, Keiko [1 ]
Rancilio, Nicholas [1 ]
Foster, Lisa [2 ]
机构
[1] Iowa State Univ, Coll Vet Med, Dept Vet Clin Sci, Ames, IA USA
[2] Iowa State Univ, Coll Vet Med, Lloyd Vet Med Ctr, Ames, IA USA
关键词
canine; feline; organ motion; radiation therapy; respiratory; BODY RADIATION-THERAPY; HEART BASE TUMORS;
D O I
10.1111/vru.13412
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Radiotherapy (RT) for lung or liver tumors can be challenging due to respiration-induced organ motion (RIOM). There are some methodological solutions to minimize RIOM. We explored a new approach to evaluate the feasibility and reproducibility of RIOM during RT with five total client-owned tumor-bearing animals using a remote-triggered breath-hold ventilator under general anesthesia during image acquisition and RT. There was one stereotactic body radiotherapy, one conventionally fractionated definitive intent, and three conventionally fractionated palliative intent RT cases. Based on repeated cone beam CT, there were no treatment table shifts required prior to initiating beam on. No clinically significant complications such as hypotension occurred during anesthesia. This technique appeared to be safe in this group of patients and was easily clinically implemented and highly reproducible. More complete follow-up data and larger studies are needed to evaluate clinical outcomes with this breath-hold ventilator technique in veterinary RT.
引用
收藏
页码:672 / 678
页数:7
相关论文
共 46 条
  • [21] Lung tumor reproducibility with active breath control (ABC) in image-guided radiotherapy based on cone-beam computed tomography with two registration methods
    Wang, Xin
    Zhong, Renming
    Bai, Sen
    Xu, Qingfeng
    Zhao, Yaqin
    Wang, Jin
    Jiang, Xiaoqin
    Shen, Yali
    Xu, Feng
    Wei, Yuquan
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) : 148 - 154
  • [22] Cone beam computed tomography-based monitoring and management of target and organ motion during external beam radiotherapy in cervical cancer
    Jensen, Nina Boje Kibsgaard
    Assenholt, Marianne Sanggaard
    Fokdal, Lars Ulrik
    Vestergaard, Anne
    Schouboe, Annette
    Kjaersgaard, Eva Bruun
    Boejen, Annette
    Nyvang, Lars
    Lindegaard, Jacob Christian
    Tanderup, Kari
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 9 : 14 - 20
  • [23] Tumor regression during radiotherapy for non-small cell lung cancer patients using cone-beam computed tomography images
    Van Timmeren, J. E.
    Van Elmpt, W.
    De Ruysscher, D.
    Reymen, B.
    Hansen, O.
    Brink, C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (02) : 159 - 171
  • [24] A prospective study to assess and quantify the setup errors with cone-beam computed tomography in head-and-neck cancer image-guided radiotherapy treatment
    Jain, Vidhi
    Soni, Tej Prakash
    Singh, Dinesh Kumar
    Patni, Nidhi
    Jakhotia, Naresh
    Gupta, Anil Kumar
    Gupta, Tara Chand
    Singhal, Harish
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) : 783 - 787
  • [25] Visual Behaviour During the Interpretation of Cone-Beam Computed Tomography Images of Traumatic Dental Injuries: An Eye-Tracking Study
    Zahran, Shatha S.
    Alghamdi, Maha S.
    Babutain, Maryam M.
    Khalifa, Hanadi M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [26] On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion
    Worm, Esben S.
    Hoyer, Morten
    Fledelius, Walther
    Nielsen, Jens E.
    Larsen, Lars P.
    Poulsen, Per R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : E145 - E151
  • [27] Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers
    Shimohigashi, Y.
    Araki, F.
    Toya, R.
    Maruyama, M.
    Nakaguchi, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3682 - 3682
  • [28] Assessing target localization accuracy across different soft-tissue matching protocols using end-exhalation breath-hold cone-beam computed tomography in patients with pancreatic cancer
    Sasaki, Makoto
    Nakamura, Mitsuhiro
    Ashida, Ryo
    Nakata, Manabu
    Yoshimura, Michio
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (04) : 711 - 719
  • [29] Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers
    Yoshinobu Shimohigashi
    Ryo Toya
    Tetsuo Saito
    Osamu Ikeda
    Masato Maruyama
    Keisuke Yonemura
    Yuji Nakaguchi
    Yudai Kai
    Yasuyuki Yamashita
    Natsuo Oya
    Fujio Araki
    Radiation Oncology, 12
  • [30] Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers
    Shimohigashi, Yoshinobu
    Toya, Ryo
    Saito, Tetsuo
    Ikeda, Osamu
    Maruyama, Masato
    Yonemura, Keisuke
    Nakaguchi, Yuji
    Kai, Yudai
    Yamashita, Yasuyuki
    Oya, Natsuo
    Araki, Fujio
    RADIATION ONCOLOGY, 2017, 12 : 61