True lumen expansion but no aortic remodeling following thoracic endografting and distal bare stent for subacute complicated type B aortic dissection

被引:0
|
作者
Chen, I-Ming [1 ,2 ]
Kuo, Tzu-Ting [1 ,2 ]
Huang, Chun-Yang [1 ,2 ]
Chen, Po-Lin [1 ,2 ]
Shih, Chun-Che [3 ]
机构
[1] Taipei Vet Gen Hosp, Dept Surg, Div Cardiovasc Surg, 201,Sect 2,Shi Pai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Sch Med, Dept Med, Taipei, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Inst Clin Med, Sch Med, Taipei, Taiwan
关键词
Bare metal stent; Stent graft; Thoracic endovascular aortic repair; Type B aortic dissection; INTERNATIONAL REGISTRY; ENDOVASCULAR TREATMENT; GRAFT PLACEMENT; REPAIR; MANAGEMENT; OUTCOMES;
D O I
10.1097/JCMA.0000000000001132
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The effects of thoracic endovascular aneurysm repair (TEVAR) with additional distal bare metal stents (BMSs) in patients with subacute complicated type B aortic dissection (cTBAD) are unclear and are investigated in this retrospective study. Methods: The medical records of 67 patients who received TEVAR due to subacute cTBAD were reviewed. Areas of true lumen (TL) and false lumen at five levels-pulmonary artery (PA), diaphragm, renal artery (RA), middle of the infrarenal aorta, and aortic bifurcation-were measured using computed tomography before and 3, 6, and 12 months after surgery. The TL ratio (TL area/total aortic area) and total aortic area at each time point were compared between the TEVAR + BMS (n = 37) and TEVAR-only (n = 30) groups. The effects of BMS use and time were evaluated using generalized estimating equations and generalized linear regression models. Results: Baseline characteristics, remodeling types, and clinical outcomes did not differ significantly between the two groups. Postoperative TL ratios at the diaphragm and RA were significantly higher in the TEVAR + BMS group than in the TEVAR-only group (p < 0.05). BMS use and time had significant interaction effects at the PA, diaphragm, and RA (all p < 0.05), but effects on total aortic area were not significant at any of the five parts. TL ratios at the diaphragm and RA exhibited greater improvement in the TEVAR + BMS group than in the TEVAR-only group at postoperative months 6 and 12 (all p < 0.001). Aortic diameters at all five parts were significantly smaller in the TEVAR + BMS group than in the TEVAR-only group (all p < 0.05). Conclusion: In patients with subacute cTBAD, TEVAR with BMS implantation effectively expands the TL from the thoracic aorta to the RA but neither enhances aortic remodeling nor elicits any change in total aortic area in whole dissected aorta relative to TEVAR only.
引用
收藏
页码:842 / 853
页数:12
相关论文
共 50 条
  • [41] Thoracic Endovascular Aortic Repair for Type B Acute Aortic Dissection Complicated by Descending Thoracic Aneurysm
    Piffaretti, G.
    Ottavi, P.
    Lomazzi, C.
    Franchin, M.
    Micheli, R.
    Ferilli, F.
    Dorigo, W.
    Marrocco-Trischitta, M.
    CasteIli, P.
    Trimarchi, S.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 53 (06) : 793 - 801
  • [42] Combined Proximal Endografting With Distal Bare-Metal Stenting for Management of Aortic Dissection
    Hofferberth, Sophie C.
    Foley, Peter T.
    Newcomb, Andrew E.
    Yap, Kelvin K.
    Yii, Michael Y.
    Nixon, Ian K.
    Wilson, Andrew M.
    Mossop, Peter J.
    ANNALS OF THORACIC SURGERY, 2012, 93 (01): : 95 - 102
  • [43] Lobato technique for acute type B aortic dissection complicated by thoracoabdominal aortic aneurysm and total true lumen occlusion of the infrarenal aorta
    Lobato, Armando C.
    Riscado, Lorrane
    Simao, Jose Reginaldo
    Meirelles, Guilherme
    Accioly, Luiz Antonio
    Camacho-Lobato, Luciana
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2022, 8 (03): : 514 - 519
  • [44] Aortic Remodeling After Thoracic Endovascular Aortic Repair for Nonacute Uncomplicated Type B Aortic Dissection
    Nomura, Yoshikatsu
    Kawasaki, Ryota
    Koide, Yutaka
    Okada, Tasuku
    Yasumori, Ken
    Sakamoto, Toshihito
    Tanaka, Hiroshi
    Murakami, Hirohisa
    ANNALS OF VASCULAR SURGERY, 2024, 99 : 209 - 216
  • [45] Early Thoracic Endovascular Aortic Repair for Type B Aortic Dissection Increases the Success of Aortic Remodeling
    Arima, Daisuke
    Suematsu, Yoshihiro
    Yamada, Ryotaro
    Nakano, Yu
    Kurahashi, Kanan
    Nishi, Satoshi
    Yoshimoto, Akihiro
    ANNALS OF VASCULAR SURGERY, 2022, 84 : 187 - 194
  • [46] Patient outcomes and thoracic aortic volume and morphologic changes following thoracic endovascular aortic repair in patients with complicated chronic type B aortic dissection
    Andacheh, Iden David
    Donayre, Carlos
    Othman, Fiezel
    Walot, Irwin
    Kopchok, George
    White, Rodney
    JOURNAL OF VASCULAR SURGERY, 2012, 56 (03) : 644 - 650
  • [48] Distal Extended Endovascular Aortic Repair PETTICOAT: A Modified Technique to Improve False Lumen Remodeling in Acute Type B Aortic Dissection
    Molinari, Alessandro C.
    Leo, Enrico
    Ferraresi, Marco
    Ferrari, Stefano A.
    Terzi, Angelo
    Sommaruga, Simona
    Rossi, Giovanni
    ANNALS OF VASCULAR SURGERY, 2019, 59 : 300 - 305
  • [49] Satisfactory Long-term Outcomes of Thoracic Endovascular Aortic Repair With a Bare Stent for Acute Complicated Type B Aortic Dissections
    Lin, Yaowang
    Dong, Shaohong
    Luo, Jianfan
    Bei, Weijie
    Liu, Qiyun
    Pang, Xinli
    Liu, Huadong
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (02) : 275 - 282
  • [50] Thoracic Endovascular Aortic Repair of Highly Tapered Type B Aortic Dissection with Proximal Tapered Stent Grafts and Distal Restrictive Stent Grafts
    Niu, Liyuan
    Bao, Xia
    Yu, Wenjuan
    Li, Changfeng
    Wu, Jiang
    Yan, Junwei
    Xin, Hai
    Wang, Haofu
    Wang, Yuewei
    ANNALS OF VASCULAR SURGERY, 2022, 86 : 380 - 388