True lumen expansion but no aortic remodeling following thoracic endografting and distal bare stent for subacute complicated type B aortic dissection

被引:0
|
作者
Chen, I-Ming [1 ,2 ]
Kuo, Tzu-Ting [1 ,2 ]
Huang, Chun-Yang [1 ,2 ]
Chen, Po-Lin [1 ,2 ]
Shih, Chun-Che [3 ]
机构
[1] Taipei Vet Gen Hosp, Dept Surg, Div Cardiovasc Surg, 201,Sect 2,Shi Pai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Sch Med, Dept Med, Taipei, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Inst Clin Med, Sch Med, Taipei, Taiwan
关键词
Bare metal stent; Stent graft; Thoracic endovascular aortic repair; Type B aortic dissection; INTERNATIONAL REGISTRY; ENDOVASCULAR TREATMENT; GRAFT PLACEMENT; REPAIR; MANAGEMENT; OUTCOMES;
D O I
10.1097/JCMA.0000000000001132
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The effects of thoracic endovascular aneurysm repair (TEVAR) with additional distal bare metal stents (BMSs) in patients with subacute complicated type B aortic dissection (cTBAD) are unclear and are investigated in this retrospective study. Methods: The medical records of 67 patients who received TEVAR due to subacute cTBAD were reviewed. Areas of true lumen (TL) and false lumen at five levels-pulmonary artery (PA), diaphragm, renal artery (RA), middle of the infrarenal aorta, and aortic bifurcation-were measured using computed tomography before and 3, 6, and 12 months after surgery. The TL ratio (TL area/total aortic area) and total aortic area at each time point were compared between the TEVAR + BMS (n = 37) and TEVAR-only (n = 30) groups. The effects of BMS use and time were evaluated using generalized estimating equations and generalized linear regression models. Results: Baseline characteristics, remodeling types, and clinical outcomes did not differ significantly between the two groups. Postoperative TL ratios at the diaphragm and RA were significantly higher in the TEVAR + BMS group than in the TEVAR-only group (p < 0.05). BMS use and time had significant interaction effects at the PA, diaphragm, and RA (all p < 0.05), but effects on total aortic area were not significant at any of the five parts. TL ratios at the diaphragm and RA exhibited greater improvement in the TEVAR + BMS group than in the TEVAR-only group at postoperative months 6 and 12 (all p < 0.001). Aortic diameters at all five parts were significantly smaller in the TEVAR + BMS group than in the TEVAR-only group (all p < 0.05). Conclusion: In patients with subacute cTBAD, TEVAR with BMS implantation effectively expands the TL from the thoracic aorta to the RA but neither enhances aortic remodeling nor elicits any change in total aortic area in whole dissected aorta relative to TEVAR only.
引用
收藏
页码:842 / 853
页数:12
相关论文
共 50 条
  • [21] Early Thoracic Endografting is Safe in Patients with Uncomplicated Type B Aortic Dissection
    Betz, Thomas
    Pfister, Karin
    Schierling, Wilma
    Sachsamanis, Georgios
    Kasprzak, Piotr
    Oikonomou, Kyriakos
    ZENTRALBLATT FUR CHIRURGIE, 2024, 149 (05): : 428 - 434
  • [22] Combined proximal descending aortic endografting plus distal bare metal stenting (PETTICOAT technique) versus conventional proximal descending aortic stent graft repair for complicated type B aortic dissections
    Rong, Dan
    Ge, Yangyang
    Liu, Jie
    Liu, Xiaoping
    Guo, Wei
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (10):
  • [23] Aortic Remodeling as a Prognostic Factor for Late Aortic Events After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection With Patent False Lumen
    Watanabe, Yoshiki
    Shimamura, Kazuo
    Yoshida, Takuya
    Daimon, Takashi
    Shirakawa, Yukitoshi
    Torikai, Kei
    Sakamoto, Tomohiko
    Shijo, Takayuki
    Toda, Koichi
    Kuratani, Toru
    Sawa, Yoshiki
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (04) : 517 - 525
  • [24] Complicated Type B aortic dissection following Type A aortic Dissection Repair: Case Report
    Isabel Pereira
    John Quarmby
    Journal of Cardiothoracic Surgery, 10 (Suppl 1)
  • [25] True lumen obliteration in complicated aortic dissection: Endovascular treatment
    Slonim, SM
    Nyman, UR
    Semba, CP
    Miller, DC
    Mitchell, RS
    Dake, MD
    RADIOLOGY, 1996, 201 (01) : 161 - 166
  • [26] Aortic visceral segment instability is evident following thoracic endovascular aortic repair for acute and subacute type B aortic dissection
    Blakeslee-Carter, Juliet
    Potter, Hellen A.
    Banks, Charles A.
    Passman, Marc
    Pearce, Benjamin
    McFarland, Graeme
    Han, Sukgu M.
    Scali, Salvatore
    Magee, Gregory A.
    Spangler, Emily
    Beck, Adam W.
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (02) : 389 - +
  • [27] TRUE LUMEN OBLITERATION IN COMPLICATED AORTIC DISSECTION - ENDOVASCULAR MANAGEMENT
    SLONIM, SM
    DAKE, MD
    SEMBA, CP
    RAZAVI, MK
    NYMAN, UR
    MILLER, DC
    MITCHELL, RS
    CIRCULATION, 1995, 92 (08) : 602 - 602
  • [28] Expansion of False Lumen Led to Rapid Aortic Enlargement in Type B Aortic Dissection
    Matsushita, Akihito
    Hattori, Takashi
    Mihara, Wahei
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E63 - E64
  • [29] Clinical Results and Aortic Remodeling After Endovascular Treatment for Complicated Type B Aortic Dissection With the "Fabulous" Stent System
    Wang, Ruihan
    Kan, Yuanqing
    Yang, Mou
    Zhang, Hongkun
    Zhang, Xiaoming
    Dai, Xiangchen
    Zhai, Shuiting
    Hu, Hejie
    Zhang, Xiwei
    Chen, Bing
    Huang, Jianhua
    Qin, Xiao
    Xiao, Zhanxiang
    Lu, Xinwu
    Guo, Wei
    Si, Yi
    Fu, Weiguo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [30] Thoracic endograft repair for a complicated type B aortic dissection
    Postol, Carolyn R.
    Yassa, Eanas S.
    ANNALS OF CARDIOTHORACIC SURGERY, 2023, 12 (06) : 606 - 608