Performance assessment of the surface-guided radiation therapy system: Varian Identify

被引:0
|
作者
Ayrancioglu, Oguzhan [1 ]
Ayrancioglu, Ceren [2 ]
Arikan, Serife Ceren [1 ]
Alicikus, Lutfiye Zumre Arican [1 ]
机构
[1] Izmir Tinaztepe Univ, Galen Hosp, Dept Radiat Oncol, Izmir, Turkiye
[2] Izmir Tinaztepe Univ, Vocat Sch, Izmir, Turkiye
关键词
Surface-guided radiation therapy; Performance assessment; Offsets; Setup accuracy; CONCOMITANT EXPOSURES; TARGET VOLUME; HEAD; VERIFICATION; ERRORS; IMRT; RISK;
D O I
10.1016/j.meddos.2024.01.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Image-guided radiotherapy (IGRT) systems using ionizing radiation may increase the risk of secondary cancer and normal tissue toxicity due to additional radiation exposure caused by large field sizes or repeated scans during X-ray imaging. As an alternative to these modalities, surface-guided radiotherapy (SGRT) systems which do not employ ionizing radiation have been developed. This study presents a comprehensive performance evaluation of the Varian Identify SGRT system by using an anthropomorphic Alderson Rando phantom in three different aspects: (a) the accuracy and reproducibility of the system in different regions of interest (ROI) for varying couch displacements, (b) the setup accuracy of the system for patient positioning based on different com puted tomography (CT) slice thicknesses, and (c) the potential influence of obstructing SGRT cameras by the gantry on the system's overall accuracy and reproducibility. The accuracy and reproducibility of the SGRT system fell within 1 mm and 1 degrees. Nevertheless, in certain situations, these values were observed to exceed prescribed limits. Consequently, concerning SGRT tolerance limits for treatment applications, careful consideration of ROIs and offset values of the system is crucial. We also recommend that patients should ideally be set up during 0 degrees gantry rotation, and the on-board imaging (OBI) system should be retracted to prevent obstruction of the cameras. Additionally, reference CT images with a slice thickness of under 3 mm are recommended for this purpose. (c) 2024 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:222 / 228
页数:7
相关论文
共 50 条
  • [21] Surface-guided setup and intrafraction motion in free-breathing breast cancer radiation therapy
    Kirkegaard, Trine O.
    Jensen, Ingelise
    Kristensen, Thomas O.
    Milo, Marie Louise H.
    Nielsen, Martin S.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3994 - S3996
  • [22] Surface-Guided Radiation Therapy (SGRT) during Stereotactic Body Radiation Therapy Treatments (SBRT) of the Lung: Dosimetric Implications of Intrafraction Motion
    Heinzerling, J. H.
    Hampton, C. J.
    Robinson, M.
    Bright, M.
    Ruiz, J. L.
    Symanowski, J. T.
    Moeller, B. J.
    Burri, S. H.
    Foster, R. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E730 - E730
  • [23] Development of a Surface-Guided Radiation Therapy (SGRT) Objective Operational Motion (SOOM) Phantom for SGRT Systems
    Kim, H.
    Kim, S.
    Sohn, J. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E147 - E148
  • [24] Clinical Experience with Intra-Fractional Motion Monitoring of Extremity Sites Under Radiation Therapy Using a Surface-Guided Imaging System
    Lee, H. W.
    Lin, C. S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7954 - 7955
  • [25] Application of surface-guided radiation therapy in prostate cancer: comparative analysis of differences with skin marking- guided patient setup
    Lee, Jaeha
    Kim, Yeon Joo
    Goh, Youngmoon
    Yang, Eunyeong
    Kim, Ha Un
    Song, Si Yeol
    Kim, Young Seok
    RADIATION ONCOLOGY JOURNAL, 2023, 41 (03): : 172 - 177
  • [26] Evaluation of dynamic accuracy and latency of a surface-guided radiotherapy system
    Yamauchi, Ryohei
    Tomita, Fumihiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 136 - 146
  • [27] Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen
    Heinzerling, John H.
    Hampton, Carnell J.
    Robinson, Myra
    Bright, Megan
    Moeller, Benjamin J.
    Ruiz, Justin
    Prabhu, Roshan
    Burri, Stuart H.
    Foster, Ryan D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (05): : 48 - 55
  • [28] Surface Guided Radiation Therapy
    Tome, Wolfgang A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 354 - 354
  • [29] Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy
    Guangyu Wang
    Zhibin Li
    Guangjun Li
    Guyu Dai
    Qing Xiao
    Long Bai
    Yisong He
    Yaxin Liu
    Sen Bai
    Radiation Oncology, 16
  • [30] Evaluation of a Mini 6DoF Plate for End-To-End Test of Surface-Guided Radiation Therapy (SGRT)
    Sohn, J.
    Polizzi, M.
    Kim, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E836 - E836