Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy

被引:1
|
作者
Abdollahi, Sara [1 ,2 ,9 ]
Mowlavi, Ali Asghar [3 ,8 ]
Yazdi, Mohammad Hadi Hadizadeh [1 ]
Ceberg, Sofie [4 ]
Aznar, Marianne Camille [5 ]
Tabrizi, Fatemeh Varshoee [6 ]
Salek, Roham [7 ]
Guckenberger, Matthias [2 ]
Tanadini-Lang, Stephanie [2 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Mashhad, Iran
[2] Univ Hosp Zurich, Dept Radiat Oncol, CH-8091 Zurich, Switzerland
[3] Hakim Sabzevari Univ, Dept Phys, Sabzevar, Iran
[4] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, England
[6] Reza Radiotherapy & Oncol Ctr, Dept Radiat Oncol, Mashhad, Iran
[7] Mashhad Univ Med Sci, Dept Radiat Oncol, Mashhad, Iran
[8] Univ Montreal, Dept Phys, Montreal, PQ, Canada
[9] Univ Hosp Zurich, CH-8091 Zurich, Switzerland
关键词
Lung SBRT; Dynamic anthropomorphic phantom; End-to-end test; LUNG-TUMOR MOTION; MITIGATION; DOSIMETRY;
D O I
10.1016/j.phro.2024.100587
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Motion management techniques are important to spare the healthy tissue adequately. However, they are complex and need dedicated quality assurance. The aim of this study was to create a dynamic phantom designed for quality assurance and to replicate a patient's size, anatomy, and tissue density. Materials and methods: A computed tomography (CT) scan of a cancer patient was used to create molds for the lungs, heart, ribs, and vertebral column via additive manufacturing. A pump system and software were developed to simulate respiratory dynamics. The extent of respiratory motion was quantified using a 4DCT scan. End- to-end tests were conducted to evaluate two motion management techniques for lung stereotactic body radiotherapy (SBRT). Results: The chest wall moved between 4 mm and 13 mm anteriorly and 2 mm to 7 mm laterally during the breathing. The diaphragm exhibited superior-inferior movement ranging from 5 mm to 16 mm in the left lung and 10 mm to 36 mm in the right lung. The left lung tumor displaced f 7 mm superior-inferiorly and anterior- posteriorly. The CT numbers were for lung:-716 f 108 HU (phantom) and-713 f 70 HU (patient); bone: 460 f 20 HU (phantom) and 458 f 206 HU (patient); soft tissue: 92 f 9 HU (phantom) and 60 f 25 HU (patient). The end-to-end testing showed an excellent agreement between the measured and the calculated dose for ion chamber and film dosimetry. Conclusions: The phantom is recommended for quality assurance, evaluating the institution's specific planning and motion management strategies either through end-to-end testing or as an external audit phantom.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Hctergeneity dose calculation accuracy in IMRT using an anthropomorphic thorax phantom
    Davidson, S.
    Prado, K.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2106 - 2106
  • [42] A realistic anthropomorphic dynamic heart phantom
    Haddad, R
    Clarysse, P
    Orkisz, M
    Croisille, P
    Revel, D
    Magnin, IE
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 801 - 804
  • [43] Using 3D Printing to Manufacture An Anthropomorphic Thorax Phantom
    Hazelaar, C.
    Dahele, M.
    van Eijnatten, M.
    Wolff, J.
    Forouzanfar, T.
    Slotman, B.
    Verbakel, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3113 - 3113
  • [44] Anthropomorphic cardiac phantom for dynamic SPECT
    A. Krakovich
    U. Zaretsky
    E. Gelbart
    I. Moalem
    A. Naimushin
    E. Rozen
    M. Scheinowitz
    R. Goldkorn
    Journal of Nuclear Cardiology, 2023, 30 : 516 - 527
  • [45] Anthropomorphic cardiac phantom for dynamic SPECT
    Krakovich, A.
    Zaretsky, U.
    Gelbart, E.
    Moalem, I
    Naimushin, A.
    Rozen, E.
    Scheinowitz, M.
    Goldkorn, R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (02) : 516 - 527
  • [46] Analysis of multiple irradiations of an anthropomorphic thorax phantom containing lung heterogeneities
    Alvarez, P. E.
    Molineu, A.
    Hernandez, N.
    Followill, D.
    Ibbott, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S685 - S685
  • [47] Dosimetric study of an indigenous and heterogeneous pelvic phantom for radiotherapy quality assurance
    Singh S.
    Raina P.
    Gurjar O.P.
    Iranian Journal of Medical Physics, 2020, 17 (02) : 120 - 125
  • [48] End-to-End Quality Assurance of Stereotactic Radiation Therapy Using an Anthropomorphic Head Phantom
    Alexander, Km
    Dekker, Kh
    Olding, T.
    Schreiner, Lj
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [49] Design, Development, and Evaluation of a Modified, Anthropomorphic, Head, Quality Assurance Phantom for Use in Stereotactic Radiosurgery
    Faught, A.
    Kry, S.
    Luo, D.
    Molineu, A.
    Bellezza, D.
    Gerber, R.
    Davidson, S.
    Bosch, W.
    Galvin, J.
    Drzymala, R.
    Timmerman, R.
    Sheehan, J.
    Gillin, M.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3746 - 3747
  • [50] Introduction of process management for quality assurance in radiotherapy
    Bruns, F
    Cortes, M
    Schroeder, F
    Sigingan-Tek, G
    Feierabend, R
    Polivka, B
    Karstens, JH
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 80 - 80