Tests on Cold-Formed Steel Laced Stub Columns: Axial Strength and Stability Characteristics

被引:1
|
作者
Dar, Mohammad Adil [1 ]
Yadav, Deepak [2 ]
Sahoo, Dipti Ranjan [3 ]
Lim, James B. P. [4 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, England
[2] Indian Inst Technol Jammu, Dept Civil Engn, Jammu 181121, J&K, India
[3] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
[4] Univ Waikato, Sch Engn, Hamilton 3240, New Zealand
关键词
Buckling; Built-up; Cold-formed steel (CFS); Closed section; Design; Laced columns; BUILT-UP COLUMNS; NUMERICAL RESEARCH; CHORD COMPACTNESS; CHANNEL SECTIONS; BEHAVIOR; DESIGN; CAPACITY; SLENDERNESS; LOAD;
D O I
10.1061/JSENDH.STENG-13240
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The research on cold-formed steel (CFS) built-up columns, which has grown over the past decade, has been instrumental in developing new CFS built-up columns with transversely spaced chords, demonstrating better axial performance than conventional I-type built-up columns. However, previous research findings on CFS laced columns have been limited, with no data available on stub columns. This paper presents the first test program for cold-formed steel laced stub columns using plain channels. The program involved fabricating 12 specimens with a single lacing configuration, connecting lacing elements and end plates to the chords using self-drilling screws, and evaluating the impact of critical parameters on column performance under concentric axial loading. Important variables such as lacing slenderness, end plate length, and transverse chord spacing were examined, with the built-up section's aspect ratio varying from 0.75 to 1.25. The failure modes, peak strengths, and load-displacement curves of the stub column specimens were used to evaluate their performance. In addition, the study compared strength predictions from the current American Iron and Steel Institute (AISI S100-16) and Eurocode (EN1993-1-3) standards against the test strengths. Unlike slender column axial strength, these current standards predicted the axial strengths of the stub columns better, with an overprediction of less than 5%. It was verified that lacing slenderness and end plate length variation does not change the failure mode in CFS laced stub columns. Further, earlier recommendations on end plate length for CFS laced columns cannot be extended to CFS laced stub columns.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental Investigation on Axial Strength Improvement of Cold-Formed Steel Jacketed Concrete Stub Columns
    Waenpracha, Apisith
    Pannachet, Tanyada
    Boonpichetvong, Maetee
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2024, 18 (01)
  • [2] Design of Cold-Formed High-Strength Steel Tubular Stub Columns
    Ma, Jia-Lin
    Chan, Tak-Ming
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (06)
  • [3] DESIGN OF COLD-FORMED HIGH STRENGTH STEEL TUBULAR STUB COLUMNS AND BEAMS
    Ma, Jia-Lin
    Chan, Tak-Ming
    Young, Ben
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [4] Cold-formed steel composite columns: axial strength and deformation response
    Dar, A. R.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2021, 6 (04)
  • [5] Cold-formed steel composite columns: axial strength and deformation response
    A. R. Dar
    Innovative Infrastructure Solutions, 2021, 6
  • [7] Axial load capacity of cold-formed steel built-up stub columns
    Mohamed Ghannam
    International Journal of Steel Structures, 2017, 17 : 1273 - 1283
  • [8] COMPRESSION TESTS OF COLD-FORMED STEEL COLUMNS
    WENG, CC
    PEKOZ, T
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (05): : 1230 - 1246
  • [9] Local buckling of corroded cold-formed steel stub columns
    Nie, Biao
    Xu, Shanhua
    Wang, Youde
    Li, Anbang
    Zhang, Zongxing
    STRUCTURES, 2021, 29 : 1837 - 1846
  • [10] EFFECT OF STRAIN RATE ON COLD-FORMED STEEL STUB COLUMNS
    KASSAR, M
    PAN, CL
    YU, WW
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (11): : 3151 - 3168