Tests on Cold-Formed Steel Laced Stub Columns: Axial Strength and Stability Characteristics

被引:1
|
作者
Dar, Mohammad Adil [1 ]
Yadav, Deepak [2 ]
Sahoo, Dipti Ranjan [3 ]
Lim, James B. P. [4 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, England
[2] Indian Inst Technol Jammu, Dept Civil Engn, Jammu 181121, J&K, India
[3] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
[4] Univ Waikato, Sch Engn, Hamilton 3240, New Zealand
关键词
Buckling; Built-up; Cold-formed steel (CFS); Closed section; Design; Laced columns; BUILT-UP COLUMNS; NUMERICAL RESEARCH; CHORD COMPACTNESS; CHANNEL SECTIONS; BEHAVIOR; DESIGN; CAPACITY; SLENDERNESS; LOAD;
D O I
10.1061/JSENDH.STENG-13240
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The research on cold-formed steel (CFS) built-up columns, which has grown over the past decade, has been instrumental in developing new CFS built-up columns with transversely spaced chords, demonstrating better axial performance than conventional I-type built-up columns. However, previous research findings on CFS laced columns have been limited, with no data available on stub columns. This paper presents the first test program for cold-formed steel laced stub columns using plain channels. The program involved fabricating 12 specimens with a single lacing configuration, connecting lacing elements and end plates to the chords using self-drilling screws, and evaluating the impact of critical parameters on column performance under concentric axial loading. Important variables such as lacing slenderness, end plate length, and transverse chord spacing were examined, with the built-up section's aspect ratio varying from 0.75 to 1.25. The failure modes, peak strengths, and load-displacement curves of the stub column specimens were used to evaluate their performance. In addition, the study compared strength predictions from the current American Iron and Steel Institute (AISI S100-16) and Eurocode (EN1993-1-3) standards against the test strengths. Unlike slender column axial strength, these current standards predicted the axial strengths of the stub columns better, with an overprediction of less than 5%. It was verified that lacing slenderness and end plate length variation does not change the failure mode in CFS laced stub columns. Further, earlier recommendations on end plate length for CFS laced columns cannot be extended to CFS laced stub columns.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Structural performance of cold-formed high strength stainless steel columns
    Ellobodya, E
    Young, B
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (12) : 1631 - 1649
  • [42] Cold-formed high strength steel tubular beam-columns
    Ma, Jia-Lin
    Chan, Tak-Ming
    Young, Ben
    ENGINEERING STRUCTURES, 2021, 230
  • [43] Direct Strength Method for Design of Cold-Formed Steel Columns with Holes
    Moen, C. D.
    Schafer, B. W.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2011, 137 (05): : 559 - 570
  • [44] Structural performance of cold-formed high strength steel tubular columns
    Fang, Han
    Chan, Tak-Ming
    Young, Ben
    ENGINEERING STRUCTURES, 2018, 177 : 473 - 488
  • [45] Numerical Investigation of Composite Behavior and Strength of Rectangular Concrete-Filled Cold-Formed Steel Tubular Stub Columns
    Wang, Liping
    An, Yanan
    Ding, Faxing
    Kuang, Yachuan
    Ma, Qing
    Tan, Sui
    Zhang, Weizhen
    Zhao, Pengzhou
    Ren, Enhui
    MATERIALS, 2021, 14 (20)
  • [46] Structural performance of concrete-filled cold-formed high-strength steel octagonal tubular stub columns
    Fang, Han
    Chan, Tak-Ming
    Young, Ben
    ENGINEERING STRUCTURES, 2021, 239
  • [47] Experimental study on cold-formed lipped channel stub columns reinforced by steel bars or steel strips
    Chen, Jian-Feng
    Chen, Ming-Qi
    Shen, Yong-Kang
    Shao, Jian-Hua
    Yang, Xin-Xin
    STEEL AND COMPOSITE STRUCTURES, 2021, 40 (03): : 339 - 354
  • [48] Experimental tests on built-up cold-formed steel section laced compression members
    Ramzy, Khaled
    Dabaon, Mohamed
    El-Boghdadi, Mahmoud
    THIN-WALLED STRUCTURES, 2022, 172
  • [49] Structural response to axial testing of cold-formed stainless steel angle columns
    Dobric, Jelena
    Filipovic, Aljosa
    Markovic, Zlatko
    Baddoo, Nancy
    THIN-WALLED STRUCTURES, 2020, 156
  • [50] Studies on cold-formed steel battened box columns under axial compression
    Beulah Gnana Ananthi, G.
    Journal of Structural Engineering (India), 2017, 44 (02): : 148 - 157