Tests on Cold-Formed Steel Laced Stub Columns: Axial Strength and Stability Characteristics

被引:1
|
作者
Dar, Mohammad Adil [1 ]
Yadav, Deepak [2 ]
Sahoo, Dipti Ranjan [3 ]
Lim, James B. P. [4 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, England
[2] Indian Inst Technol Jammu, Dept Civil Engn, Jammu 181121, J&K, India
[3] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
[4] Univ Waikato, Sch Engn, Hamilton 3240, New Zealand
关键词
Buckling; Built-up; Cold-formed steel (CFS); Closed section; Design; Laced columns; BUILT-UP COLUMNS; NUMERICAL RESEARCH; CHORD COMPACTNESS; CHANNEL SECTIONS; BEHAVIOR; DESIGN; CAPACITY; SLENDERNESS; LOAD;
D O I
10.1061/JSENDH.STENG-13240
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The research on cold-formed steel (CFS) built-up columns, which has grown over the past decade, has been instrumental in developing new CFS built-up columns with transversely spaced chords, demonstrating better axial performance than conventional I-type built-up columns. However, previous research findings on CFS laced columns have been limited, with no data available on stub columns. This paper presents the first test program for cold-formed steel laced stub columns using plain channels. The program involved fabricating 12 specimens with a single lacing configuration, connecting lacing elements and end plates to the chords using self-drilling screws, and evaluating the impact of critical parameters on column performance under concentric axial loading. Important variables such as lacing slenderness, end plate length, and transverse chord spacing were examined, with the built-up section's aspect ratio varying from 0.75 to 1.25. The failure modes, peak strengths, and load-displacement curves of the stub column specimens were used to evaluate their performance. In addition, the study compared strength predictions from the current American Iron and Steel Institute (AISI S100-16) and Eurocode (EN1993-1-3) standards against the test strengths. Unlike slender column axial strength, these current standards predicted the axial strengths of the stub columns better, with an overprediction of less than 5%. It was verified that lacing slenderness and end plate length variation does not change the failure mode in CFS laced stub columns. Further, earlier recommendations on end plate length for CFS laced columns cannot be extended to CFS laced stub columns.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Compression tests of high strength cold-formed cross-shaped steel columns
    University of Sydney, School of Civil Engineering, Centre for Advanced Structural Engineering
    Res. Rep. Univ. Sydney. Dep. Civil. Eng., 2006, 869 (1-115):
  • [22] Design of concrete-filled cold-formed steel elliptical stub columns
    Yi, Shusheng
    Chen, Man-Tai
    Young, Ben
    ENGINEERING STRUCTURES, 2023, 276
  • [23] Experimental study of concrete filled cold-formed steel tubular stub columns
    Zhu, Aizhu
    Zhang, Xiaowu
    Zhu, Hongping
    Zhu, Jihua
    Lu, Yong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 134 : 17 - 27
  • [24] Experimental and theoretical study on the behavior of cold-formed stainless steel stub columns
    Ganping Shu
    Baofeng Zheng
    Xiaoming Shen
    International Journal of Steel Structures, 2013, 13 : 141 - 153
  • [25] Design for openings in equal-angle cold-formed steel stub columns
    Dhanalakshmi, M
    Shanmugam, NE
    THIN-WALLED STRUCTURES, 2001, 39 (02) : 167 - 187
  • [26] Compression tests on cold-formed steel columns with monosymmetrical section
    Moldovan, A.
    Thin-Walled Structures, 1994, 20 (1 -4 pt 2) : 241 - 252
  • [27] Experimental and theoretical study on the behavior of cold-formed stainless steel stub columns
    Shu, Ganping
    Zheng, Baofeng
    Shen, Xiaoming
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (01) : 141 - 153
  • [28] Experimental investigation on performance of perforated cold-formed steel tubular stub columns
    Singh, Tekcham Gishan
    Singh, Konjengbam Darunkumar
    THIN-WALLED STRUCTURES, 2018, 131 : 107 - 121
  • [29] Compression tests of cold-formed plain and dimpled steel columns
    Nguyen, V. B.
    Wang, C. J.
    Mynors, D. J.
    English, M. A.
    Castellucci, M. A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 69 (01) : 20 - 29
  • [30] ULTIMATE CAPACITY OF COLD-FORMED STEEL HOLLOW STUB COLUMNS WITH ELLIPTICAL PERFORATIONS
    Singh, Tekcham G.
    Singh, Konjengbam D.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 607 - 616