A Forked Microvascular Phantom for Ultrasound Localization Microscopy Investigations

被引:0
|
作者
Shangguan, Hanyue [1 ,2 ]
Yiu, Billy Y. S. [1 ,2 ,3 ]
Chee, Adrian J. Y. [1 ,2 ]
Yu, Alfred C. H. [1 ,2 ]
机构
[1] Univ Waterloo, Schlegel Res Inst Aging, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
[3] Tech Univ Denmark, Dept Hlth Technol, DK-2800 Lyngby, Denmark
基金
美国国家卫生研究院;
关键词
Lumen; Phantoms; Microscopy; Acoustics; Location awareness; Containers; Casting; Additive manufacturing; forked lumen; microvascular phantom; ultrasound localization microscopy (ULM); 3-D ULTRASOUND; SUPERRESOLUTION; RESOLUTION; IMAGE; ANGIOGENESIS; LIMIT; FLOW;
D O I
10.1109/TUFFC.2024.3409518
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the development of ultrasound localization microscopy (ULM) methods, appropriate test beds are needed to facilitate algorithmic performance calibration. Here, we present the design of a new ULM-compatible microvascular phantom with a forked, V-shaped wall-less flow channel pair ( 250 mu m channel width) that is bifurcated at a separation rate of 50 mu m/mm. The lumen core was fabricated using additive manufacturing, and it was molded within a polyvinyl alcohol (PVA) tissue-mimicking slab using the lost-core casting method. Measured using optical microscopy, the lumen core's flow channel width was found to be 252 +/- 15 mu m with a regression-derived flow channel separation gradient of 50.89 mu m/mm. The new phantom's applicability in ULM performance analysis was demonstrated by feeding microbubble (MB) contrast flow (1.67 to 167 mu L/s flow rates) through the phantom's inlet and generating ULM images with a previously reported method. Results showed that, with longer acquisition times (10 s or longer), ULM image quality was expectedly improved, and the variance of ULM-derived flow channel measurements was reduced. Also, at axial depths near the lumen's bifurcation point, the current ULM algorithm showed difficulty in properly discerning between the two flow channels because of the narrow channel-to-channel separation distance. Overall, the new phantom serves well as a calibration tool to test the performance of ULM methods in resolving small vasculature.
引用
收藏
页码:887 / 896
页数:10
相关论文
共 50 条
  • [41] Deep Learning in Ultrasound Localization Microscopy: Applications and Perspectives
    Rauby, Brice
    Xing, Paul
    Gasse, Maxime
    Provost, Jean
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (12) : 1765 - 1784
  • [42] A Deep Learning Framework for Spatiotemporal Ultrasound Localization Microscopy
    Milecki, Leo
    Poree, Jonathan
    Belgharbi, Hatim
    Bourquin, Chloe
    Damseh, Rafat
    Delafontaine-Martel, Patrick
    Lesage, Frederic
    Gasse, Maxime
    Provost, Jean
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (05) : 1428 - 1437
  • [43] Transthoracic ultrasound localization microscopy of myocardial vasculature in patients
    Yan, Jipeng
    Huang, Biao
    Tonko, Johanna
    Toulemonde, Matthieu
    Hansen-Shearer, Joseph
    Tan, Qingyuan
    Riemer, Kai
    Ntagiantas, Konstantinos
    Chowdhury, Rasheda A.
    Lambiase, Pier D.
    Senior, Roxy
    Tang, Meng-Xing
    NATURE BIOMEDICAL ENGINEERING, 2024, 8 (06) : 689 - 700
  • [44] Microbubble detection with adaptive beamforming for Ultrasound Localization Microscopy
    Corazza, Alexandre
    Muleki-Seya, Pauline
    Aissani, Abderrahmane Walid
    Couture, Olivier
    Basarab, Adrian
    Nicolas, Barbara
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [45] Deep Learning Based Microbubble Localization for Fast and Robust Ultrasound Localization Microscopy
    Chen, Xi
    Lowerison, Matthew R.
    Dong, Zhijie
    Sekaran, Nathiya Vaithiyalingam Chandra
    Zhang, Wei
    Llano, Daniel A.
    Song, Pengfei
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [46] Transcranial ultrasound localization microscopy in moyamoya patients using a clinical ultrasound system
    Denis, Louise
    Meseguer, Elena
    Gaudemer, Augustin
    Jaklh, Georges
    Bodard, Sylvain
    Chabouh, Georges
    Herve, Dominique
    Vicaut, Eric
    Amarenco, Pierre
    Couture, Olivier
    THERANOSTICS, 2025, 15 (09): : 4074 - 4083
  • [47] Ultrasound Localization Microscopy Precision of Clinical 3-D Ultrasound Systems
    Dencks, Stefanie
    Lisson, Thomas
    Oblisz, Nico
    Kiessling, Fabian
    Schmitz, Georg
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (12) : 1677 - 1689
  • [48] Dynamic contrast enhanced ultrasound imaging; the effect of imaging modes and parameter settings for a microvascular phantom
    Moghimirad, Elahe
    Bamber, Jeffrey
    Harris, Emma
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [49] LOCALIZATION OF MICROVASCULAR AND MICROCIRCULATORY RESPONSES TO VENOUS-PRESSURE ELEVATION BY IN VIVO MICROSCOPY
    BAEZ, S
    LAIDLAW, Z
    ORKIN, LR
    ACTA PHYSIOLOGICA LATINOAMERICANA, 1973, 23 (03) : 8 - 8
  • [50] THE MICROVASCULAR LOCALIZATION OF LAMININ AND FIBRONECTIN IN SCLERODERMA MUSCLE BY IMMUNE ELECTRON-MICROSCOPY
    HANNA, WM
    RUSSELL, ML
    FRIESEN, D
    ULTRASTRUCTURAL PATHOLOGY, 1986, 10 (03) : 221 - 226