Vascular function in patients with advanced heart failure and continuous-flow or pulsatile ventricular assist devices

被引:0
|
作者
Rossi, Valentina A. [1 ]
Nebunu, Delia [1 ]
Nagele, Matthias P. [1 ]
Barthelmes, Jens [1 ]
Haider, Thomas [1 ]
Laptseva, Natallia [1 ]
Bitos, Konstantinos [1 ]
Kreysing, Leonie [1 ]
Frank, Michelle [1 ]
Enseleit, Frank [1 ]
Wilhelm, Markus J. [2 ]
Dzemali, Omer [2 ]
Ruschitzka, Frank [1 ]
Sudano, Isabella [1 ]
Flammer, Andreas J. [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Cardiol, Zurich, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Clin Cardiac Surg, Zurich, Switzerland
关键词
Endothelial function; Ventricular assist device; Retinal vessel analysis; Pulsatile blood flow; Advanced heart failure; ENDOTHELIAL FUNCTION; RISK; INFLAMMATION; REACTIVITY; ARTERY; FOCUS;
D O I
10.1007/s00392-024-02519-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A significant proportion of patients with heart failure (HF) progress to an advanced stage, which is associated with a substantial increase in morbidity and mortality. These patients may be eligible for advanced treatment strategies such as mechanical circulatory support with ventricular assist devices (VAD). Vascular dysfunction is a hallmark of heart failure pathophysiology and prognosis. However, whether and to what degree the hemodynamic benefits of VADs influence vascular function remain unknown. Methods and results In this study, we evaluated endothelial vascular function with flow-mediated vasodilatation (FMD) and with flicker-light induced retinal vasodilatation (FID). 34 patients with a VAD (age 58 +/- 10 years, 85% male, 74% ischemic heart disease, 26 continuous-flow (CF)-LVAD, and 8 pulsatile biventricular (bi)-VAD) were compared to 34 propensity-matched patients (mean age 62 +/- 9 years, 68% male, 59% ischemic heart disease) with advanced HF (AdvHF). Endothelial function of larger arteries (FMD) was significantly better in patients after VAD implantation compared to matched AdvHF patients (7.2 +/- 4.6% vs. 5.0 +/- 3.2%, p = 0.03), whereas microvascular arteriolar function (FIDart) did not differ (0.99 +/- 1.43% vs. 1.1 +/- 1.7%, p = 0.78). The arterio-venous ratio (AVR) was higher in the VAD group (0.90 +/- 0.06 vs 0.85 +/- 0.09, p = 0.01), reflecting wider retinal arteriolar and narrower venular diameters. There was no difference in vascular function between patients with CF-LVAD and pulsatile Bi-VAD. Conclusion In patients with advanced heart failure, VAD implantation was associated with better endothelial function at the level of large arteries, but not in the microcirculation.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Comparison of continuous-flow and pulsatile-flow left ventricular assist devices: is there an advantage to pulsatility?
    Cheng, Allen
    Williamitis, Christine A.
    Slaughter, Mark S.
    ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (06) : 573 - 581
  • [32] Bleeding and Thrombosis in Patients With Continuous-Flow Ventricular Assist Devices
    Eckman, Peter M.
    John, Ranjit
    CIRCULATION, 2012, 125 (24) : 3038 - 3047
  • [33] Sublingual microcirculation in patients with continuous-flow ventricular assist devices
    Wadowski, P. P.
    Steinlechner, B.
    Zimpfer, D.
    Schloeglhofer, T.
    Schima, H.
    Huelsmann, M.
    Wurm, R.
    Gremmel, T.
    Koppensteiner, R.
    Schoergenhofer, C.
    Jilma, B.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 161 - 162
  • [34] Trauma in Patients With Continuous-Flow Left Ventricular Assist Devices
    Sarsam, Sinan H.
    Meyers, Deborah E.
    Civitello, Andrew B.
    Agunanne, Enoch E.
    Odegaard, Peggy
    Cohn, William E.
    Frazier, O. H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (09): : 1520 - 1522
  • [35] The Safety of Right Heart Catheterization in Patients with Continuous-Flow Left Ventricular Assist Devices
    Patel, Kershaw
    Rodgers, Daniel
    Henderson, Cory
    Anyanwu, Emeka
    Fedson, Savitri
    Kim, Gene
    Sarswat, Nitasha
    Juricek, Colleen
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (08) : S32 - S33
  • [36] A Novel Extracorporeal Continuous-Flow Ventricular Assist System for Patients With Advanced Heart Failure - Initial Clinical Experience -
    Seguchi, Osamu
    Fujita, Tomoyuki
    Kitahata, Nana
    Iwasaki, Keiichiro
    Kuroda, Kensuke
    Nakajima, Seiko
    Watanabe, Takuya
    Yanase, Masanobu
    Fukushima, Satsuki
    Tsukiya, Tomonori
    Katagiri, Nobumasa
    Mizuno, Toshihide
    Takewa, Yoshiaki
    Hamasaki, Toshimitsu
    Onda, Kaori
    Hayashi, Teruyuki
    Yamamoto, Haruko
    Tatsumi, Eisuke
    Kobayashi, Junjiro
    Fukushima, Norihide
    CIRCULATION JOURNAL, 2020, 84 (07) : 1090 - +
  • [37] Hemodynamic Predictors of Right Heart Failure Requiring Right Ventricular Assist Devices After Continuous-flow Left Ventricular Assist Devices Placement
    Lee, Dae Hyun
    Stachura, Zachary
    Kulkarni, Deepika
    Feliberti, Jason P.
    Restrepo-Jaramillo, Ricardo
    CIRCULATION, 2019, 140
  • [38] Elevated Pulmonary Vascular Resistance is the Strongest Echocardiographic Parameter Associated With Clinical Heart Failure in Patients With Continuous-Flow Left Ventricular Assist Devices
    Vivo, Rey P.
    Aldeiri, Molham
    Lopez-Mattei, Juan C.
    Cordero-Reyes, Andrea M.
    Loebe, Matthias
    Bruckner, Brian A.
    Torre-Amione, Guillermo
    Bhimaraj, Arvind
    Estep, Jerry D.
    JOURNAL OF CARDIAC FAILURE, 2012, 18 (08) : S40 - S40
  • [39] The risk of right ventricular failure with current continuous-flow left ventricular assist devices
    Loforte, Antonio
    Grigioni, Francesco
    Marinelli, Giuseppe
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (12) : 969 - 983
  • [40] Arterial Stiffness and Vascular Endothelial Function in Patients with Long-Term Continuous-Flow Left Ventricular Assist Devices
    Morgan, Nani
    Warner, Patrick
    Kiernan, Michael
    Al-Quthami, Adeeb
    Rahban, Youssef
    Duc Thinh Pham
    DeNofrio, David
    Karas, Richard
    Kuvin, Jeffrey
    JOURNAL OF CARDIAC FAILURE, 2013, 19 (08) : S18 - S18