Vascular function in patients with advanced heart failure and continuous-flow or pulsatile ventricular assist devices

被引:0
|
作者
Rossi, Valentina A. [1 ]
Nebunu, Delia [1 ]
Nagele, Matthias P. [1 ]
Barthelmes, Jens [1 ]
Haider, Thomas [1 ]
Laptseva, Natallia [1 ]
Bitos, Konstantinos [1 ]
Kreysing, Leonie [1 ]
Frank, Michelle [1 ]
Enseleit, Frank [1 ]
Wilhelm, Markus J. [2 ]
Dzemali, Omer [2 ]
Ruschitzka, Frank [1 ]
Sudano, Isabella [1 ]
Flammer, Andreas J. [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Cardiol, Zurich, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Clin Cardiac Surg, Zurich, Switzerland
关键词
Endothelial function; Ventricular assist device; Retinal vessel analysis; Pulsatile blood flow; Advanced heart failure; ENDOTHELIAL FUNCTION; RISK; INFLAMMATION; REACTIVITY; ARTERY; FOCUS;
D O I
10.1007/s00392-024-02519-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A significant proportion of patients with heart failure (HF) progress to an advanced stage, which is associated with a substantial increase in morbidity and mortality. These patients may be eligible for advanced treatment strategies such as mechanical circulatory support with ventricular assist devices (VAD). Vascular dysfunction is a hallmark of heart failure pathophysiology and prognosis. However, whether and to what degree the hemodynamic benefits of VADs influence vascular function remain unknown. Methods and results In this study, we evaluated endothelial vascular function with flow-mediated vasodilatation (FMD) and with flicker-light induced retinal vasodilatation (FID). 34 patients with a VAD (age 58 +/- 10 years, 85% male, 74% ischemic heart disease, 26 continuous-flow (CF)-LVAD, and 8 pulsatile biventricular (bi)-VAD) were compared to 34 propensity-matched patients (mean age 62 +/- 9 years, 68% male, 59% ischemic heart disease) with advanced HF (AdvHF). Endothelial function of larger arteries (FMD) was significantly better in patients after VAD implantation compared to matched AdvHF patients (7.2 +/- 4.6% vs. 5.0 +/- 3.2%, p = 0.03), whereas microvascular arteriolar function (FIDart) did not differ (0.99 +/- 1.43% vs. 1.1 +/- 1.7%, p = 0.78). The arterio-venous ratio (AVR) was higher in the VAD group (0.90 +/- 0.06 vs 0.85 +/- 0.09, p = 0.01), reflecting wider retinal arteriolar and narrower venular diameters. There was no difference in vascular function between patients with CF-LVAD and pulsatile Bi-VAD. Conclusion In patients with advanced heart failure, VAD implantation was associated with better endothelial function at the level of large arteries, but not in the microcirculation.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Neurocognitive function in patients with ventricular assist devices: A comparison of pulsatile and continuous blood flow devices
    Zimpfer, D
    Wieselthaler, G
    Czerny, M
    Fakin, R
    Haider, D
    Zrunek, P
    Roethy, W
    Schima, H
    Wolner, E
    Grimm, M
    ASAIO JOURNAL, 2006, 52 (01) : 24 - 27
  • [23] Sex differences in continuous-flow ventricular assist device therapy for advanced heart failure
    Matsumoto, Yorihiko
    Fukushima, Satsuki
    Shimahara, Yusuke
    Tadokoro, Naoki
    Kakuta, Takashi
    Kobayashi, Junjiro
    Fujita, Tomoyuki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2021, 69 (06) : 919 - 925
  • [24] Sex differences in continuous-flow ventricular assist device therapy for advanced heart failure
    Yorihiko Matsumoto
    Satsuki Fukushima
    Yusuke Shimahara
    Naoki Tadokoro
    Takashi Kakuta
    Junjiro Kobayashi
    Tomoyuki Fujita
    General Thoracic and Cardiovascular Surgery, 2021, 69 : 919 - 925
  • [25] Vascular Function in Heart Failure Patients Implanted with a Continuous-Flow Left Ventricular Assist Device: Impact of Increasing Peripheral Pulsatility
    Hydren, Jay R.
    Gifford, Jayson R.
    Jarrett, Catherine L.
    Park, Soung Hun
    Shields, Katherine L.
    Ratchford, Stephen M.
    Broxterman, Ryan M.
    Kithas, Andrew C.
    Thurston, Taylor S.
    Selzman, Craig H.
    Drakos, Stavros G.
    Richardson, Russell S.
    FASEB JOURNAL, 2019, 33
  • [26] The incidence of right ventricular dysfunction is similar in pulsatile and continuous-flow left ventricular assist devices
    Feller, Erika D.
    Sorensen, Erik N.
    Johnson, Frances L.
    Gottlieb, Stephen S.
    Haddad, Michel
    Pierson, Richard N.
    Griffith, Bartley P.
    JOURNAL OF CARDIAC FAILURE, 2006, 12 (06) : S49 - S49
  • [27] Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading
    Garcia, Santiago
    Kandar, Forum
    Boyle, Andrew
    Colvin-Adams, Monica
    Lliao, Kenneth
    Joyce, Lyle
    John, Ranjit
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (03): : 261 - 267
  • [28] Ventricular Arrhythmias in Patients With Continuous-flow Left Ventricular Assist Devices
    Kuten, David
    McLean, Rhondalyn
    Russell, Stuart
    CIRCULATION, 2013, 128 (22)
  • [29] Ventricular arrhythmias in patients with continuous-flow left ventricular assist devices
    Gkouziouta, A. Aggeliki
    Bonios, M.
    Zarkalis, D.
    Adamopoulos, S.
    Kogerakis, N.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 75 - 75
  • [30] 4.4: Middle Cerebral Artery Pulsatility in Heart Failure and Patients with Continuous-Flow Left Ventricular assist Devices
    Eric Stöhr
    Francesco Castagna
    James Pearson
    Laura Watkeys
    Samuel Trocio
    Oksana Zatvarska
    Timothy Crimmins
    Alberto Pinsino
    Paolo Colombo
    Melana Yuzefpolskaya
    Reshad Garan
    Veli Topkara
    Hiroo Takayama
    Koji Takeda
    Yoshifumi Naka
    John Cockcroft
    Joshua Willey
    Barry McDonnell
    Artery Research, 2017, 20 (1) : 57 - 57