Quantitative calcium-based assessment of osteoporosis in dual-layer spectral CT

被引:2
|
作者
Do, T. D. [1 ]
Rahn, S. [1 ]
Melzig, C. [1 ]
Heussel, C. P. [2 ]
Stiller, W. [1 ]
Kauczor, H. U. [1 ]
Weber, T. F. [1 ]
Skornitzke, S. [1 ]
机构
[1] Heidelberg Univ Hosp, Clin Diag & Intervent Radiol DIR, Im Neuenheimer Feld 130 3, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Thoraxklin, Diag & Intervent Radiol Nucl Med, Heidelberg, Germany
关键词
Computed tomography; Osteoporosis; Calcium imaging; Dual-layer detector; BONE-MINERAL DENSITY; X-RAY ABSORPTIOMETRY; COMPUTED-TOMOGRAPHY; POSTMENOPAUSAL WOMEN; ENERGY; ACCURACY; CONTRAST;
D O I
10.1016/j.ejrad.2024.111606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate a novel calcium-only imaging technique (VCa) with subtracted bone marrow in osteoporosis in dual-layer CT (DLCT) compared to conventional CT images (CI) and dual-energy X-ray absorptiometry (DXA). Material and methods: Images of a multi-energy CT phantom with calcium inserts, quantitative CT calibration phantom, and of 55 patients (mean age: 64.6 +/- 11.5 years) were acquired on a DLCT to evaluate bone mineral density (BMD). CI, calcium-suppressed images, and VCa were calculated. For investigating the association of VCa and CI with DXA a subsample of 30 patients (<90 days between DXA and CT) was used. Multiple regression analysis was performed to identify further factors improving the prediction of DXA BMD. Results: The calcium concentrations of the CT phantom inserts were significantly associated with CT numbers from VCa (R-2 = 0.94) and from CI (R-2 = 0.89-0.92). VCa showed significantly higher CT numbers than CI in the phantom (p <= 0.001) and clinical setting (p < 0.001). CT numbers from VCa were significantly associated with CI (R-2 = 0.95, p < 0.001) and with DXA (R-2 = 0.31, p = 0.007), whereas no significant association between DXA and CI was found. Prediction of DXA BMD based on CT numbers derived from VCa yielded R-2 = 0.76 in multiple regression analysis. ROC for the differentiation of normal from pathologic BMD in VCa yielded an AUC of 0.7, and a cut-off value of 126HU (sensitivity: 0.90; specificity: 0.47). Conclusion: VCa images showed better agreement with DXA and known calcium concentrations than CI, and could be used to estimate BMD. A VCa cut-off of 126 HU could be used to identify abnormal bone mineral density.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Differential diagnosis of adrenal adenomas and metastases using spectral parameters in dual-layer detector spectral CT
    Wu, Lei-di
    Yue, Xiao-fei
    Wu, Lin-xia
    Yang, Ming
    Chen, Yan
    Yu, Jie
    Diao, Nan
    Zhang, Xiao-hui
    Zhu, Liang-ru
    Han, Ping
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (12) : 10453 - 10463
  • [42] Differential diagnosis of adrenal adenomas and metastases using spectral parameters in dual-layer detector spectral CT
    Lei-di Wu
    Xiao-fei Yue
    Lin-xia Wu
    Ming Yang
    Yan Chen
    Jie Yu
    Nan Diao
    Xiao-hui Zhang
    Liang-ru Zhu
    Ping Han
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 10453 - 10463
  • [43] Opportunistic osteoporosis screening: contrast-enhanced dual-layer spectral CT provides accurate measurements of vertebral bone mineral density
    Ferdinand Roski
    Johannes Hammel
    Kai Mei
    Bernhard Haller
    Thomas Baum
    Jan S. Kirschke
    Daniela Pfeiffer
    Klaus Woertler
    Franz Pfeiffer
    Peter B. Noël
    Alexandra S. Gersing
    Benedikt J. Schwaiger
    European Radiology, 2021, 31 : 3147 - 3155
  • [44] Calcium decomposition and phantomless bone mineral density measurements using dual-layer based spectral computed tomography
    Mei, Kai
    Schwaiger, Benedikt J.
    Kopp, Felix K.
    Ehn, Sebastian
    Gersing, Alexandra S.
    Kirschke, Jan S.
    Muenzel, Daniela
    Fingerle, Alexander A.
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Baum, Thomas
    Noel, Peter B.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [45] Unenhanced Dual-Layer Spectral-Detector CT for Characterizing Indeterminate Adrenal Lesions
    Nagayama, Yasunori
    Inoue, Taihei
    Oda, Seitaro
    Tanoue, Shota
    Nakaura, Takeshi
    Morinaga, Jun
    Ikeda, Osamu
    Hirai, Toshinori
    RADIOLOGY, 2021, 301 (02) : 369 - 378
  • [46] Improved Sensitivity and Reader Confidence in CT Colonography Using Dual-Layer Spectral CT: A Phantom Study
    Obmann, Markus M.
    An, Chansik
    Schaefer, Amanda
    Sun, Yuxin
    Wang, Zhen J.
    Yee, Judy
    Yeh, Benjamin M.
    RADIOLOGY, 2020, 297 (01) : 99 - 107
  • [47] Image quality evaluation of dual-layer spectral detector CT of the chest and comparison with conventional CT imaging
    Doerner, Jonas
    Hauger, Myriam
    Hickethier, Tilman
    Byrtus, Jonathan
    Wybranski, Christian
    Hokamp, Nils Grosse
    Maintz, David
    Haneder, Stefan
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 52 - 58
  • [48] Bene fit of dual-layer spectral CT in emergency imaging of different organ systems
    Simsir, B. Demirler
    Danse, E.
    Coche, E.
    CLINICAL RADIOLOGY, 2020, 75 (12) : 886 - 902
  • [49] Initial exploration of coronary stent image subtraction using dual-layer spectral CT
    Le Qin
    ShengJia Gu
    ChiHua Chen
    Huan Zhang
    ZhenBin Zhu
    XingBiao Chen
    Qun Han
    FuHua Yan
    WenJie Yang
    European Radiology, 2019, 29 : 4239 - 4248
  • [50] Initial exploration of coronary stent image subtraction using dual-layer spectral CT
    Qin, Le
    Gu, ShengJia
    Chen, ChiHua
    Zhang, Huan
    Zhu, ZhenBin
    Chen, XingBiao
    Han, Qun
    Yan, FuHua
    Yang, WenJie
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4239 - 4248