Melanin bias in pulse oximetry explained by light source spectral bandwidth

被引:4
|
作者
Bierman, Andrew [1 ]
Benner, Kevin [2 ]
Rea, Mark S. [2 ]
机构
[1] Namreiba LLC, Albany, NY USA
[2] Icahn Sch Med Mt Sinai, Light & Hlth Res Ctr, Dept Populat Hlth Sci & Policy, New York, NY 10029 USA
关键词
Beer-Lambert law; melanin bias; photoplethysmography; polychromatic light; pulse oximetry; spectral bandwidth; OXYGEN-SATURATION; ACCURACY;
D O I
10.1016/j.bja.2024.01.037
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Pulse oximetry uses noninvasive optical measurements of light transmission from each of two sources through vascularised living tissue over the cardiac cycle (SpO2). From those measurements, the relative amount of oxygenated haemoglobin (SaO2) in circulating blood can be deduced. Recent reports have shown that, compared with SaO2 measurements from blood samples, SpO2 measurements are biased erroneously high for patients with dark skin. Methods: We developed a new method, spectrally resolved photoplethysmography (srPPG), to examine how spectral bandwidth affects the transmission of polychromatic light through the fingertip across the cardiac cycle. We measured and recorded the spectral transmission through the fingertip as the O2 concentration in inspired air was reduced. We applied digital spectral filters of two different bandwidths, narrow or broad, to the same srPPG recordings to determine whether SpO2 readings systematically varied for the two bandwidths. The srPPG method also allowed us to measure the fractional amount of melanin in the optical path. The effect of melanin content on the ratio of SpO2 readings for narrow and broad spectral bandwidths was analysed. Results: We hypothesised, based upon the Beer-Lambert law, and then showed experimentally, that the light emission spectra of light-emitting diode light sources, as used in commercial pulse oximeters, result in erroneously high SpO2 measurements for patients having greater melanin concentrations in their skin than those of the subject pool used for instrument calibration. Conclusions: To eliminate melanin bias, pulse oximeters should use much narrower spectral bandwidths than those used in current models.
引用
收藏
页码:957 / 963
页数:7
相关论文
共 50 条
  • [21] The Light-Tissue Interaction of Pulse Oximetry
    Mannheimer, Paul D.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S10 - S17
  • [22] Bandwidth correction for spectral irradiance of source with narrow bandwidth
    Wang, Yanfei
    Dai, Caihong
    Wu, Zhifeng
    Chen, Binhua
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGING SPECTROSCOPY; AND TELESCOPES AND LARGE OPTICS, 2014, 9298
  • [23] Active Noise Cancellation of Motion Artifacts in Pulse Oximetry Using Isobestic Wavelength Light Source
    Wang, Chun-Yen
    Tang, Kea-Tiong
    2011 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2011, : 1029 - 1032
  • [24] Towards Spectral Pulse Oximetry independent of motion artifacts
    Von Chong, Alejandro
    Terosiet, Mehdi
    Histace, Aymeric
    Romain, Olivier
    2018 21ST EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD 2018), 2018, : 479 - 483
  • [25] Source-Detector Spectral Pairing-Related Inaccuracies in Pulse Oximetry: Evaluation of the Wavelength Shift
    Tsiakaka, Olivier
    Gosselin, Benoit
    Feruglio, Sylvain
    SENSORS, 2020, 20 (11) : 1 - 17
  • [26] Modification of Oximeter Ratio to Reduce Pigmentation Bias in Pulse Oximetry
    Arefin, Mohammed Shahriar
    Shmuylovich, Leonid
    Patil, Chetan A.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XVII, 2024, 12833
  • [27] Monte Carlo based Simulations of Racial bias in Pulse Oximetry
    Arefin, Mohammed Shahriar
    Dumont, Alexander P.
    Patil, Chetan A.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XV, 2022, 11951
  • [28] RACIAL BIAS IN PULSE OXIMETRY IN ACUTE HYPOXEMIC RESPIRATORY FAILURE
    Balmaceda, Julia
    Gerber, Eryn D.
    Arnold, Michael J.
    Williams, Dominique A.
    Snyder, Karen
    Pandya, Sahil M.
    CHEST, 2022, 162 (04) : 1168A - 1168A
  • [29] Broadband superluminescent diode light source at 1330 nm with 180 nm spectral bandwidth
    Kostin, Yu
    Chamorovskiy, A.
    Yakubovich, S. D.
    ELECTRONICS LETTERS, 2015, 51 (05) : 408 - 409
  • [30] Light-emitting diode surgical light interference with pulse oximetry
    Schulz, Erich B.
    Ham, John A.
    BRITISH JOURNAL OF ANAESTHESIA, 2019, 123 (04) : E490 - E491