Hybrid paper/PDMS microfluidic device integrated with RNA extraction and recombinase polymerase amplification for detection of norovirus in foods

被引:0
|
作者
Lu, Yuxiao [1 ,2 ]
Hua, Marti Z. [2 ]
Luo, Yuhang [1 ]
Lu, Xiaonan [2 ]
Liu, Qian [1 ,3 ]
机构
[1] McGill Univ, Inst Parasitol, Ste Anne De Bellevue, PQ, Canada
[2] McGill Univ, Dept Food Sci & Agr Chem, Ste Anne De Bellevue, PQ, Canada
[3] Jewish Gen Hosp, Lady Davis Inst, McGill Ctr Viral Dis, Montreal, PQ, Canada
关键词
microfluidic device; lab-on-a-chip; isothermal amplification; food safety; norovirus; MURINE NOROVIRUS; VIRUS; INACTIVATION;
D O I
10.1128/aem.01208-24
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Human norovirus (HuNoV) is recognized as the leading causative agent of foodborne outbreaks of epidemic gastroenteritis. Consequently, there is a high demand for developing point-of-care testing for HuNoV. We developed an origami microfluidic device that facilitates rapid detection of murine norovirus 1 (MNV-1), a surrogate for HuNoV, encompassing the entire process from sample preparation to result visualization. This process includes RNA absorption via a paper strip, RNA amplification using recombinase polymerase amplification (RPA), and a lateral flow assay for signal readout. The on-chip detection of MNV-1 was completed within 35 min, demonstrating 100% specificity to MNV-1 in our settings. The detection limit of this microfluidic device for MNV-1 was 200 PFU/mL, comparable to the in-tube RPA reaction. It also successfully detected MNV-1 in lettuce and raspberries at concentrations of 170 PFU/g and 230 PFU/g, respectively, without requiring extra concentration steps. This device demonstrates high compatibility with isothermal nucleic acid amplification and holds significant potential for detecting foodborne viruses in agri-food products in remote and resource-limited settings.IMPORTANCEHuNoV belongs to the family of Caliciviridae and is a leading cause of acute gastroenteritis that can be transmitted through contaminated foods. HuNoV causes around one out of five cases of acute gastroenteritis that lead to diarrhea and vomiting, placing a substantial burden on the healthcare system worldwide. HuNoV outbreaks can occur when food is contaminated at the source (e.g., wild mussels exposed to polluted water), on farms (e.g., during crop cultivation, harvesting, or livestock handling), during packaging, or at catered events. The research outcomes of this study expand the approaches of HuNoV testing, adding value to the framework for routine testing of food products. This microfluidic device can facilitate the monitoring of HuNoV outbreaks, reduce the economic loss of the agri-food industry, and enhance food safety. HuNoV belongs to the family of Caliciviridae and is a leading cause of acute gastroenteritis that can be transmitted through contaminated foods. HuNoV causes around one out of five cases of acute gastroenteritis that lead to diarrhea and vomiting, placing a substantial burden on the healthcare system worldwide. HuNoV outbreaks can occur when food is contaminated at the source (e.g., wild mussels exposed to polluted water), on farms (e.g., during crop cultivation, harvesting, or livestock handling), during packaging, or at catered events. The research outcomes of this study expand the approaches of HuNoV testing, adding value to the framework for routine testing of food products. This microfluidic device can facilitate the monitoring of HuNoV outbreaks, reduce the economic loss of the agri-food industry, and enhance food safety.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] An Integrated Paper Microfluidic Device Based on Isothermal Amplification for Simple Sample-to-Answer Detection of Campylobacter jejuni
    Chen, Yunxuan
    Hu, Yaxi
    Lu, Xiaonan
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2023, 89 (07)
  • [22] NOVEL EXTRACTION PROTOCOL AND RECOMBINASE POLYMERASE AMPLIFICATION ASSAY FOR DETECTION OF LEISHMANIA DONOVANI IN 30 MINUTES
    Mondal, Dinesh
    Ghosh, Prakash
    Khan, Md. Anik Ashfaq
    Hossain, Faria
    Bohlken-Fascher, Susanne
    Matlashewski, Greg
    Kroeger, Axel
    Olliaro, Piero
    Abd El Wahed, Ahmed
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 95 (05): : 396 - 397
  • [23] Comparison of RNA Extraction Methods for the Detection of a Norovirus Surrogate in Ready-to-Eat Foods
    Girard, Maryline
    Morales-Rayas, Rocio
    Jean, Julie
    FOODBORNE PATHOGENS AND DISEASE, 2013, 10 (01) : 47 - 54
  • [24] Detection of the select agent Rathayibacter toxicus using recombinase polymerase amplification coupled with a lateral flow device
    Arif, M.
    Busot, G.
    Mann, R.
    Rodoni, B.
    Stack, J.
    PHYTOPATHOLOGY, 2016, 106 (12) : 23 - 23
  • [25] A Glass/PDMS Hybrid Microfluidic Chip Embedded with Integrated Electrodes for Contactless Conductivity Detection
    Li, Ou-an
    Tong, Yan-Li
    Chen, Zuan-Guang
    Liu, Cui
    Zhao, Shen
    Mo, Jin-Yuan
    CHROMATOGRAPHIA, 2008, 68 (11-12) : 1039 - 1044
  • [26] A Glass/PDMS Hybrid Microfluidic Chip Embedded with Integrated Electrodes for Contactless Conductivity Detection
    Ou-Lian Li
    Yan-Li Tong
    Zuan-Guang Chen
    Cui Liu
    Shen Zhao
    Jin-Yuan Mo
    Chromatographia, 2008, 68 : 1039 - 1044
  • [27] A pump-free paper/PDMS hybrid microfluidic chip for bacteria enrichment and fast detection
    Zhu, Zhengshan
    Lv, Zilan
    Wang, Li
    Tan, Haolan
    Xu, Yi
    Li, Shunbo
    Chen, Li
    TALANTA, 2024, 275
  • [28] A highly integrated system with rapid DNA extraction, recombinase polymerase amplification, and lateral flow biosensor for on-site detection of genetically modified crops
    Wang, Xiaofu
    Chen, Yu
    Chen, Xiaoyun
    Peng, Cheng
    Wang, Liu
    Xu, Xiaoli
    Wu, Jian
    Wei, Wei
    Xu, Junfeng
    ANALYTICA CHIMICA ACTA, 2020, 1109 (1109) : 158 - 168
  • [29] Hybrid Integrated CMOS-Microfluidic Device for the Detection and Characterization of Particles
    Hosseini, Yahya
    Hartley, Lee F.
    Kaler, Karan V. I. S.
    2008 1ST MICROSYSTEMS AND NANOELECTRONICS RESEARCH CONFERENCE, 2008, : 49 - 52
  • [30] An LED-Driven AuNPs-PDMS Microfluidic Chip and Integrated Device for the Detection of Digital Loop-Mediated Isothermal DNA Amplification
    Zhang, Zengming
    Zhao, Shuhao
    Hu, Fei
    Yang, Guangpu
    Li, Juan
    Tian, Hui
    Peng, Niancai
    MICROMACHINES, 2020, 11 (02)