Radiation dose reduction and image quality in pediatric paranasal sinus CT: with automatic tube current modulation and iterative reconstruction technique

被引:0
|
作者
Chen, Xiao-Fang [1 ]
Zhang, Yi-Chi [1 ]
Ding, Ning [1 ]
Liu, Li [1 ]
Ji, Yi-Ding [1 ]
Zhang, Chao [2 ]
Chi, Jing [1 ]
机构
[1] Soochow Univ, Suzhou Peoples Hosp 9, Dept Radiol, 2666 Ludang Rd, Suzhou 215200, Jiangsu, Peoples R China
[2] Soochow Univ, Suzhou Peoples Hosp 9, Dept Anesthesiol, 2666 Ludang Rd, Suzhou 215200, Jiangsu, Peoples R China
关键词
MULTIDETECTOR CT; CHILDREN; EXPOSURE;
D O I
10.1093/rpd/ncae192
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Our objective is to evaluate radiation dose and image quality in pediatric paranasal sinus computed tomography (CT) with automatic tube current modulation (ATCM) and sinogram-affirmed iterative reconstruction algorithm (SAFIRE). CT scans from 80 patients were divided into two groups: Group A [80 kVp, pitch 1.5, 40 mAs, the filtered back projection (FBP) algorithm] and Group B (70 kVp, pitch 3, ATCM with reference at 40 mAs, SAFIRE strengths 1-5). We have evaluated image quality and radiation dose. Group B demonstrated significantly lower volume computed tomography dose index, dose-length product, and effective dose than Group A (0.13 +/- 0.03 vs. 1.57 +/- 0.01 mGy, 2.27 +/- 0.82 vs. 19.88 +/- 2.01 mGy<middle dot>cm, and 0.0081 +/- 0.0017 vs. 0.079 +/- 0.013 mSv, respectively; P < .001). Increasing SAFIRE strengths correlated with noise reduction and SNR enhancement. Group B's noise and SNRsoft at SAFIRE strength 5 were comparable with Group A. Images reconstructed with SAFIRE strength 5 in Group B exhibit comparable image quality with FBP in Group A.
引用
收藏
页码:1470 / 1476
页数:7
相关论文
共 50 条
  • [41] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Tricarico, Francesco
    Hlavacek, Anthony M.
    Schoepf, U. Joseph
    Ebersberger, Ullrich
    Nance, John W., Jr.
    Vliegenthart, Rozemarijn
    Cho, Young Jun
    Spears, J. Reid
    Secchi, Francesco
    Savino, Giancarlo
    Marano, Riccardo
    Schoenberg, Stefan O.
    Bonomo, Lorenzo
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1306 - 1315
  • [42] Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?
    Euler A.
    Stieltjes B.
    Schindera S.T.
    Emergency Radiology, 2017, 24 (1) : 31 - 37
  • [43] Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniques
    Francesco Tricarico
    Anthony M. Hlavacek
    U. Joseph Schoepf
    Ullrich Ebersberger
    John W. Nance
    Rozemarijn Vliegenthart
    Young Jun Cho
    J. Reid Spears
    Francesco Secchi
    Giancarlo Savino
    Riccardo Marano
    Stefan O. Schoenberg
    Lorenzo Bonomo
    Paul Apfaltrer
    European Radiology, 2013, 23 : 1306 - 1315
  • [44] CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction
    Ebersberger, Ullrich
    Tricarico, Francesco
    Schoepf, U. Joseph
    Blanke, Philipp
    Spears, J. Reid
    Rowe, Garrett W.
    Halligan, William T.
    Henzler, Thomas
    Bamberg, Fabian
    Leber, Alexander W.
    Hoffmann, Ellen
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 125 - 132
  • [45] CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction
    Ullrich Ebersberger
    Francesco Tricarico
    U. Joseph Schoepf
    Philipp Blanke
    J. Reid Spears
    Garrett W. Rowe
    William T. Halligan
    Thomas Henzler
    Fabian Bamberg
    Alexander W. Leber
    Ellen Hoffmann
    Paul Apfaltrer
    European Radiology, 2013, 23 : 125 - 132
  • [46] Metallic prosthesis: Technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients
    Dalal, T
    Kalra, MK
    Rizzo, SMR
    Schmidt, B
    Suess, C
    Flohr, T
    Blake, MA
    Saini, S
    RADIOLOGY, 2005, 236 (02) : 671 - 675
  • [47] Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT
    Smith, Ethan A.
    Dillman, Jonathan R.
    Goodsitt, Mitchell M.
    Christodoulou, Emmanuel G.
    Keshavarzi, Nahid
    Strouse, Peter J.
    RADIOLOGY, 2014, 270 (02) : 526 - 534
  • [48] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Haesung Yoon
    Myung-Joon Kim
    Choon-Sik Yoon
    Jiin Choi
    Hyun Joo Shin
    Hyun Gi Kim
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 337 - 344
  • [49] Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose
    Aurumskjold, Marie-Louise
    Soderberg, Marcus
    Stalhammar, Fredrik
    von Steyern, Kristina Vult
    Tingberg, Anders
    Ydstrom, Kristina
    ACTA RADIOLOGICA, 2018, 59 (06) : 740 - 747
  • [50] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344