Radiation dose reduction and image quality in pediatric paranasal sinus CT: with automatic tube current modulation and iterative reconstruction technique

被引:0
|
作者
Chen, Xiao-Fang [1 ]
Zhang, Yi-Chi [1 ]
Ding, Ning [1 ]
Liu, Li [1 ]
Ji, Yi-Ding [1 ]
Zhang, Chao [2 ]
Chi, Jing [1 ]
机构
[1] Soochow Univ, Suzhou Peoples Hosp 9, Dept Radiol, 2666 Ludang Rd, Suzhou 215200, Jiangsu, Peoples R China
[2] Soochow Univ, Suzhou Peoples Hosp 9, Dept Anesthesiol, 2666 Ludang Rd, Suzhou 215200, Jiangsu, Peoples R China
关键词
MULTIDETECTOR CT; CHILDREN; EXPOSURE;
D O I
10.1093/rpd/ncae192
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Our objective is to evaluate radiation dose and image quality in pediatric paranasal sinus computed tomography (CT) with automatic tube current modulation (ATCM) and sinogram-affirmed iterative reconstruction algorithm (SAFIRE). CT scans from 80 patients were divided into two groups: Group A [80 kVp, pitch 1.5, 40 mAs, the filtered back projection (FBP) algorithm] and Group B (70 kVp, pitch 3, ATCM with reference at 40 mAs, SAFIRE strengths 1-5). We have evaluated image quality and radiation dose. Group B demonstrated significantly lower volume computed tomography dose index, dose-length product, and effective dose than Group A (0.13 +/- 0.03 vs. 1.57 +/- 0.01 mGy, 2.27 +/- 0.82 vs. 19.88 +/- 2.01 mGy<middle dot>cm, and 0.0081 +/- 0.0017 vs. 0.079 +/- 0.013 mSv, respectively; P < .001). Increasing SAFIRE strengths correlated with noise reduction and SNR enhancement. Group B's noise and SNRsoft at SAFIRE strength 5 were comparable with Group A. Images reconstructed with SAFIRE strength 5 in Group B exhibit comparable image quality with FBP in Group A.
引用
收藏
页码:1470 / 1476
页数:7
相关论文
共 50 条
  • [11] Reduction of effective dose and organ dose to the eye lens in head MDCT using iterative image reconstruction and automatic tube current modulation
    Ryska, Pavel
    Kvasnicka, Tomas
    Jandura, Jiri
    Klzo, Ludovit
    Grepl, Jakub
    Zizka, Jan
    BIOMEDICAL PAPERS-OLOMOUC, 2014, 158 (02): : 265 - 272
  • [12] Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography
    Lee, E. J.
    Lee, S. K.
    Agid, R.
    Howard, P.
    Bae, J. M.
    terBrugge, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (09) : 1754 - 1759
  • [13] Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D)
    Shen, Hesong
    Dai, Guochao
    Luo, Mingyue
    Duan, Chaijie
    Cai, Wenli
    Liang, Dan
    Wang, Xinhua
    Zhu, Dongyun
    Li, Wenru
    Qiu, Jianping
    PLOS ONE, 2015, 10 (11):
  • [14] Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography A Phantom Study on Radiation Dose and Image Quality
    Papadalds, Antonios E.
    Damilakis, John
    INVESTIGATIVE RADIOLOGY, 2019, 54 (05) : 265 - 272
  • [15] Radiation Dose Reduction via Sinogram Affirmed Iterative Reconstruction and Automatic Tube Voltage Modulation (CARE kV) in Abdominal CT
    Shin, Hyun Joo
    Chung, Yong Eun
    Lee, Young Han
    Choi, Jin-Young
    Park, Mi-Suk
    Kim, Myeong-Jin
    Kim, Ki Whang
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (06) : 886 - 893
  • [16] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [17] Calculation of dose reduction by tube current modulation in pediatric CT
    Schmidt, B
    Greess, H
    Wolf, H
    Kalender, WA
    RADIOLOGY, 2001, 221 : 365 - 366
  • [18] Combined Use of Automatic Tube Potential Selection with Tube Current Modulation and Iterative Reconstruction Technique in Coronary CT Angiography
    Suh, Young Joo
    Kim, Young Jin
    Hong, Sae Rom
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Hur, Jin
    Choi, Byoung Wook
    RADIOLOGY, 2013, 269 (03) : 722 - 729
  • [19] CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose
    Zhao, Yong-Xia
    Zuo, Zi-Wei
    Suo, Hong-Na
    Wang, Jia-ning
    Chang, Jin
    ACADEMIC RADIOLOGY, 2016, 23 (12) : 1513 - 1520
  • [20] Multidetector CT of the paranasal sinus: Potential for radiation dose reduction
    Brem, Matthias H.
    Zamani, Amir A.
    Riva, Roberto
    Zou, Kelly H.
    Rumboldt, Zoran
    Hennig, Friedrich F.
    Kikinis, Ron
    Norbash, Alexander M.
    Schoepf, U. Joseph
    RADIOLOGY, 2007, 243 (03) : 847 - 852