Radiation dose reduction and image quality in pediatric paranasal sinus CT: with automatic tube current modulation and iterative reconstruction technique

被引:0
|
作者
Chen, Xiao-Fang [1 ]
Zhang, Yi-Chi [1 ]
Ding, Ning [1 ]
Liu, Li [1 ]
Ji, Yi-Ding [1 ]
Zhang, Chao [2 ]
Chi, Jing [1 ]
机构
[1] Soochow Univ, Suzhou Peoples Hosp 9, Dept Radiol, 2666 Ludang Rd, Suzhou 215200, Jiangsu, Peoples R China
[2] Soochow Univ, Suzhou Peoples Hosp 9, Dept Anesthesiol, 2666 Ludang Rd, Suzhou 215200, Jiangsu, Peoples R China
关键词
MULTIDETECTOR CT; CHILDREN; EXPOSURE;
D O I
10.1093/rpd/ncae192
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Our objective is to evaluate radiation dose and image quality in pediatric paranasal sinus computed tomography (CT) with automatic tube current modulation (ATCM) and sinogram-affirmed iterative reconstruction algorithm (SAFIRE). CT scans from 80 patients were divided into two groups: Group A [80 kVp, pitch 1.5, 40 mAs, the filtered back projection (FBP) algorithm] and Group B (70 kVp, pitch 3, ATCM with reference at 40 mAs, SAFIRE strengths 1-5). We have evaluated image quality and radiation dose. Group B demonstrated significantly lower volume computed tomography dose index, dose-length product, and effective dose than Group A (0.13 +/- 0.03 vs. 1.57 +/- 0.01 mGy, 2.27 +/- 0.82 vs. 19.88 +/- 2.01 mGy<middle dot>cm, and 0.0081 +/- 0.0017 vs. 0.079 +/- 0.013 mSv, respectively; P < .001). Increasing SAFIRE strengths correlated with noise reduction and SNR enhancement. Group B's noise and SNRsoft at SAFIRE strength 5 were comparable with Group A. Images reconstructed with SAFIRE strength 5 in Group B exhibit comparable image quality with FBP in Group A.
引用
收藏
页码:1470 / 1476
页数:7
相关论文
共 50 条
  • [1] Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique
    Bang, Minseo
    Choi, Seong Hoon
    Park, Jongha
    Kang, Byeong Seong
    Kwon, Woon Jung
    Lee, Tae Hoon
    Nam, Jung Gwon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 982 - 987
  • [2] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [3] Reducing the radiation dose of pediatric paranasal sinus CT using an ultralow tube voltage (70 kVp) combined with iterative reconstruction Feasibility and image quality
    Chi, Jing
    Xu, Dongfeng
    Yin, Shengnan
    Li, Man
    Shen, Li
    Ding, Ning
    Chen, Xiaofang
    Ji, Yiding
    MEDICINE, 2020, 99 (34) : E21886
  • [4] Radiation Dose Reduction in Paranasal Sinus CT Using Model-Based Iterative Reconstruction
    Hoxworth, J. M.
    Lal, D.
    Fletcher, G. P.
    Patel, A. C.
    He, M.
    Paden, R. G.
    Hara, A. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (04) : 644 - 649
  • [5] Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis
    Lee, Sanghee
    Yoon, Sang-Wook
    Yoo, Seung-Min
    Ji, Young Geon
    Kim, Kyoung Ah
    Kim, Sang Heum
    Lee, Jong Tae
    ACTA RADIOLOGICA, 2011, 52 (10) : 1101 - 1106
  • [6] Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation
    Herzog, Christopher
    Mulvihill, Denise M.
    Nguyen, Shaun A.
    Savino, Giancarlo
    Schmidt, Bernhard
    Costello, Philip
    Vogl, Thomas J.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) : 1232 - 1240
  • [7] Ultra-low dose CT colonography with automatic tube current modulation and sinogram-affirmed iterative reconstruction: Effects on radiation exposure and image quality
    Cianci, Roberta
    Pizzi, Andrea Delli
    Esposito, Gianliugi
    Timpani, Mauro
    Tavoletta, Alessandra
    Pulsone, Pierluigi
    Basilico, Raffaella
    Cotroneo, Antonio Raffaele
    Filippone, Antonella
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 321 - 330
  • [8] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [9] DOSE AND IMAGE QUALITY IN LOW-DOSE CT FOR URINARY STONE DISEASE: ADDED VALUE OF AUTOMATIC TUBE CURRENT MODULATION AND ITERATIVE RECONSTRUCTION TECHNIQUES
    Soenen, Olivier
    Balliauw, Christophe
    Oyen, Raymond
    Zanca, Federica
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (02) : 242 - 249
  • [10] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    RADIOLOGY, 2012, 263 (02) : 537 - 546