A treatment-site-specific evaluation of commercial synthetic computed tomography solutions for proton therapy

被引:0
|
作者
Yeap, Ping Lin [1 ,2 ]
Wong, Yun Ming [1 ,3 ]
Lee, Kang Hao [1 ]
Koh, Calvin Wei Yang [1 ]
Lew, Kah Seng [1 ,3 ]
Chua, Clifford Ghee Ann [1 ,3 ]
Wibawa, Andrew [1 ]
Master, Zubin [1 ]
Lee, James Cheow Lei [1 ,3 ]
Park, Sung Yong [1 ,4 ]
Tan, Hong Qi [1 ,3 ,4 ]
机构
[1] Natl Canc Ctr Singapore, Div Radiat Oncol, Singapore, Singapore
[2] Univ Cambridge, Dept Oncol, Cambridge, England
[3] Nanyang Technol Univ, Div Phys & Appl Phys, Singapore, Singapore
[4] Duke NUS Med Sch, Oncol Acad Clin Programme, Singapore, Singapore
关键词
Proton therapy; Adaptive radiotherapy; Synthetic CT; Cone-beam CT; CONE-BEAM CT; ADAPTIVE RADIOTHERAPY; CANCER; PHOTON;
D O I
10.1016/j.phro.2024.100639
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Despite the superior dose conformity of proton therapy, the dose distribution is sensitive to daily anatomical changes, which can affect treatment accuracy. This study evaluated the dose recalculation accuracy of two synthetic computed tomography (sCT) generation algorithms in a commercial treatment planning system. Materials and methods: The evaluation was conducted for head-and-neck, thorax-and-abdomen, and pelvis sites treated with proton therapy. Thirty patients with two cone-beam computed tomography (CBCT) scans each were selected. The sCT images were generated from CBCT scans using two algorithms, Corrected CBCT (corrCBCT) and Virtual CT (vCT). Dose recalculations were performed based on these images for comparison with "ground truth" deformed CTs. Results: The choice of algorithm influenced dose recalculation accuracy, particularly in high dose regions. For head-and-neck cases, the corrCBCT method showed closer agreement with the "ground truth", while for thoraxand-abdomen and pelvis cases, the vCT algorithm yielded better results (mean percentage dose discrepancy of 0.6 %, 1.3 % and 0.5 % for the three sites, respectively, in the high dose region). Head-and-neck and pelvis cases exhibited excellent agreement in high dose regions (2 %/2 mm gamma passing rate >98 %), while thorax-andabdomen cases exhibited the largest differences, suggesting caution in sCT algorithm usage for this site. Significant systematic differences were observed in the clinical target volume and organ-at-risk doses in head-andneck and pelvis cases, highlighting the importance of using the correct algorithm. Conclusions: This study provided treatment site-specific recommendations for sCT algorithm selection in proton therapy. The findings offered insights for proton beam centers implementing adaptive radiotherapy workflows.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] An optimized framework for cone-beam computed tomography-based online evaluation for proton therapy
    Chang, Chih-Wei
    Nilsson, Rasmus
    Andersson, Sebastian
    Bohannon, Duncan
    Patel, Sagar A.
    Patel, Pretesh R.
    Liu, Tian
    Yang, Xiaofeng
    Zhou, Jun
    MEDICAL PHYSICS, 2023, 50 (09) : 5375 - 5386
  • [22] Therapy Response Evaluation with Positron Emission Tomography-Computed Tomography
    Segall, George M.
    SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (06) : 490 - 495
  • [23] Evaluation of a commercial Model Based Iterative reconstruction algorithm in computed tomography
    Paruccini, Nicoletta
    Villa, Raffaele
    Pasquali, Claudia
    Spadavecchia, Chiara
    Baglivi, Antonia
    Crespi, Andrea
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 58 - 70
  • [24] COMPUTED TOMOGRAPHY IN RADIATION-THERAPY TREATMENT PLANNING
    HENDEE, WR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (5-6): : 539 - 540
  • [25] COMPUTED TOMOGRAPHY IN RADIATION THERAPY TREATMENT PLANNING.
    Fritz, Steven L.
    Lee, Kyo Rak
    Tarlton, Mark A.
    Mansfield, Carl M.
    Automedica, 1981, 4 (01): : 63 - 74
  • [26] Evaluation of the Ethos synthetic computed tomography for bolus-covered surfaces
    Wegener, Sonja
    Schindhelm, Robert
    Tamihardja, Jorg
    Sauer, Otto A.
    Razinskas, Gary
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113
  • [27] Quantitative Comparison of Proton, Helium- and Carbon-Ion Computed Tomography for Ion Therapy Treatment Planning
    Meyer, S.
    Kamp, F.
    Mairani, A.
    Belka, C.
    Carlson, D.
    Gianoli, C.
    Parodi, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E510 - E510
  • [28] Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning
    Norris, H.
    Rangaraj, D.
    Kim, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3448 - 3448
  • [29] DOSIMETRIC EVALUATION OF A COMPUTED-TOMOGRAPHY TREATMENT SYSTEM
    PRASAD, SC
    GLASGOW, GP
    PURDY, JA
    RADIOLOGY, 1979, 130 (03) : 777 - 781
  • [30] COMPUTED-TOMOGRAPHY IN THE EVALUATION AND TREATMENT OF ENDOMETRIAL CARCINOMA
    HASUMI, K
    MATSUZAWA, M
    CHEN, HF
    TAKAHASHI, M
    SAKURA, M
    CANCER, 1982, 50 (05) : 904 - 908