Evaluation of the Ethos synthetic computed tomography for bolus-covered surfaces

被引:3
|
作者
Wegener, Sonja [1 ]
Schindhelm, Robert [1 ]
Tamihardja, Jorg [1 ]
Sauer, Otto A. [1 ]
Razinskas, Gary [1 ]
机构
[1] Univ Hosp Wuerzburg, Dept Radiat Oncol, Josef Schneider Str 11, D-97080 Wurzburg, Germany
关键词
Adaptive radiotherapy; Ethos; Synthetic CT; Bolus; CONE-BEAM CT; ONLINE; SYSTEM;
D O I
10.1016/j.ejmp.2023.102662
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Ethos allows online adaption of radiotherapy treatment plans. Dose is calculated on synthetic computed tomographies (sCT), CT-like images generated by deforming planning CTs (pCT) onto daily cone beam CTs (CBCT) acquired during treatment sessions. Errors in sCT density distribution may lead to dose calculation errors. sCT correctness was investigated for bolus-covered surfaces.Methods: pCTs were recorded of a slab phantom covered with bolus of different thicknesses and with air gaps introduced by spacer rings of variable diameters and heights. Treatment plans were irradiated following the adaptive workflow with different bolus configurations present in the pCT and CBCT. sCT densities were compared to those of the pCT for the same air gap size. Additionally, the neck region of an anthropomorphic phantom was imaged using a plane standard bolus versus an individual bolus adapted to the phantom's outer contour.Results: Varying bolus thickness by 5 mm between pCT and CBCT was reproduced in the sCT within 2 mm ac-curacy. Different air gaps in pCT and CBCT resulted in highly variable bolus thickness in the sCT with a typical error of 5 mm or more. In extreme cases, air gaps were filled with bolus material density in the sCT or the phantom was unrealistically deformed near changed bolus geometries. Changes in bolus thickness and deformation also occurred in the anthropomorphic phantom.Conclusion: sCTs must be critically examined and included in plan-specific quality assurance. The use of tight-fitting air gap-free bolus should be preferred to increase the similarity between sCT and CBCT.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] BOLUS DYNAMIC COMPUTED-TOMOGRAPHY IN THE EVALUATION OF PULMONARY SEQUESTRATION
    BUCKWALTER, KA
    GROSS, BH
    HERNANDEZ, RJ
    CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1987, 11 (04): : 335 - 340
  • [2] PROSPECTIVE RANDOMIZED COMPARISON OF CONVENTIONAL AND TRIPLE BOLUS COMPUTED TOMOGRAPHY FOR HEMATURIA EVALUATION
    Lama, Daniel
    Parkhomenko, Egor
    Lall, Chandana
    Patel, Roshan
    Kaler, Kamaljot
    Clayman, Ralph
    Landman, Jaime
    JOURNAL OF UROLOGY, 2018, 199 (04): : E847 - E847
  • [3] Synthetic aperture computed tomography
    Akiyama, I
    Yano, K
    ACOUSTICAL IMAGING, VOL 23, 1997, 23 : 575 - 581
  • [4] Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods
    Ayaka Chiba
    Kohei Harada
    Yoshiya Ohashi
    Kanako Numasawa
    Tatsuya Imai
    Shun Hayasaka
    Radiological Physics and Technology, 2020, 13 : 92 - 97
  • [5] Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods
    Chiba, Ayaka
    Harada, Kohei
    Ohashi, Yoshiya
    Numasawa, Kanako
    Imai, Tatsuya
    Hayasaka, Shun
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (01) : 92 - 97
  • [6] Dose reduction with adaptive bolus chasing computed tomography angiography
    Cai, Zhijun
    Bai, Er-Wei
    Wang, Ge
    Sharafuddin, Melhem J.
    Abada, Hicham T.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (01) : 15 - 25
  • [7] Single-phase Split-bolus Dual Energy Computed Tomography Angiography for Evaluation of Hemoptysis
    Meena, Pankaj
    Bhalla, Ashu S.
    Goyal, Ankur
    Sharma, Raju
    Kumar, Atin
    Srivastva, Deep N.
    Sreenivas, Vishnu
    Guleria, Randeep
    JOURNAL OF THORACIC IMAGING, 2018, 33 (06) : 366 - 376
  • [8] Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography
    Eisa, Fabian
    Brauweiler, Robert
    Peetz, Alexander
    Hupfer, Martin
    Nowak, Tristan
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (10): : N173 - N182
  • [9] The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles
    Cassel, Nicolette
    Carstens, Ann
    Becker, Pieter
    JOURNAL OF THE SOUTH AFRICAN VETERINARY ASSOCIATION-TYDSKRIF VAN DIE SUID-AFRIKAANSE VETERINERE VERENIGING, 2013, 84 (01):
  • [10] Computed Tomography, Computed Tomography Angiography, and Perfusion Computed Tomography Evaluation of Acute Ischemic Stroke
    Leiva-Salinas, Carlos
    Jiang, Bin
    Wintermark, Max
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2018, 28 (04) : 565 - 572