A treatment-site-specific evaluation of commercial synthetic computed tomography solutions for proton therapy

被引:0
|
作者
Yeap, Ping Lin [1 ,2 ]
Wong, Yun Ming [1 ,3 ]
Lee, Kang Hao [1 ]
Koh, Calvin Wei Yang [1 ]
Lew, Kah Seng [1 ,3 ]
Chua, Clifford Ghee Ann [1 ,3 ]
Wibawa, Andrew [1 ]
Master, Zubin [1 ]
Lee, James Cheow Lei [1 ,3 ]
Park, Sung Yong [1 ,4 ]
Tan, Hong Qi [1 ,3 ,4 ]
机构
[1] Natl Canc Ctr Singapore, Div Radiat Oncol, Singapore, Singapore
[2] Univ Cambridge, Dept Oncol, Cambridge, England
[3] Nanyang Technol Univ, Div Phys & Appl Phys, Singapore, Singapore
[4] Duke NUS Med Sch, Oncol Acad Clin Programme, Singapore, Singapore
关键词
Proton therapy; Adaptive radiotherapy; Synthetic CT; Cone-beam CT; CONE-BEAM CT; ADAPTIVE RADIOTHERAPY; CANCER; PHOTON;
D O I
10.1016/j.phro.2024.100639
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Despite the superior dose conformity of proton therapy, the dose distribution is sensitive to daily anatomical changes, which can affect treatment accuracy. This study evaluated the dose recalculation accuracy of two synthetic computed tomography (sCT) generation algorithms in a commercial treatment planning system. Materials and methods: The evaluation was conducted for head-and-neck, thorax-and-abdomen, and pelvis sites treated with proton therapy. Thirty patients with two cone-beam computed tomography (CBCT) scans each were selected. The sCT images were generated from CBCT scans using two algorithms, Corrected CBCT (corrCBCT) and Virtual CT (vCT). Dose recalculations were performed based on these images for comparison with "ground truth" deformed CTs. Results: The choice of algorithm influenced dose recalculation accuracy, particularly in high dose regions. For head-and-neck cases, the corrCBCT method showed closer agreement with the "ground truth", while for thoraxand-abdomen and pelvis cases, the vCT algorithm yielded better results (mean percentage dose discrepancy of 0.6 %, 1.3 % and 0.5 % for the three sites, respectively, in the high dose region). Head-and-neck and pelvis cases exhibited excellent agreement in high dose regions (2 %/2 mm gamma passing rate >98 %), while thorax-andabdomen cases exhibited the largest differences, suggesting caution in sCT algorithm usage for this site. Significant systematic differences were observed in the clinical target volume and organ-at-risk doses in head-andneck and pelvis cases, highlighting the importance of using the correct algorithm. Conclusions: This study provided treatment site-specific recommendations for sCT algorithm selection in proton therapy. The findings offered insights for proton beam centers implementing adaptive radiotherapy workflows.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Clinical evaluation of synthetic computed tomography methods in adaptive proton therapy of lung cancer patients
    Taasti, Vicki Trier
    Hattu, Djoya
    Peeters, Stephanie
    van der Salm, Anke
    van der Loon, Judith
    de Ruysscher, Dirk
    Nilsson, Rasmus
    Andersson, Sebastian
    Engwall, Erik
    Unipan, Mirko
    Canters, Richard
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [2] Evaluation of magnetic resonance imaging derived synthetic computed tomography for proton therapy planning in prostate cancer
    Fridstrom, Kajsa M. L.
    Winter, Rene M.
    Hornik, Natalie
    Almberg, Sigrun S.
    Danielsen, Signe
    Redalen, Kathrine R.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [3] Clinical implementation of a commercial synthetic computed tomography solution for radiotherapy treatment of glioblastoma
    Emin, Sevgi
    Rossi, Elia
    Rooth, Elisabeth Myrvold
    Dorniok, Torsten
    Hedman, Mattias
    Gagliardi, Giovanna
    Villegas, Fernanda
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [4] The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy
    Tsai, Pingfang
    Tseng, Yu-Lun
    Shen, Brian
    Ackerman, Christopher
    Zhai, Huifang A.
    Yu, Francis
    Simone II, Charles B.
    Choi, J. Isabelle
    Lee, Nancy Y.
    Kabarriti, Rafi
    Lazarev, Stanislav
    Johnson, Casey L.
    Liu, Jiayi
    Chen, Chin-Cheng
    Lin, Haibo
    CANCERS, 2023, 15 (20)
  • [5] Development of Proton Computed Tomography for Applications in Proton Therapy
    Bashkirov, Vladimir
    Schulte, Reinhard
    Coutrakon, George
    Erdelyi, Bela
    Wong, Kent
    Sadrozinski, Hartmut
    Penfold, Scott
    Rosenfeld, Anatoly
    McAllister, Scott
    Schubert, Keith
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 460 - +
  • [6] Evaluation of particle trajectories in proton computed tomography
    Denyak, V.
    Paschuk, S. A.
    Schelin, H. R.
    Setti, J-A-P
    Klock, M. C. L.
    Paschuk, A.
    Evseev, I.
    Yevseyeva, O.
    Mesa, J.
    VI LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2007, 884 : 504 - +
  • [7] Adaptive Proton Therapy Dose Evaluation and Planning Using Cone Beam Computed Tomography
    Ackerman, C.
    Tsai, P.
    Zhai, H.
    Kang, M.
    Apinorasethkul, C.
    Bhatti, D.
    Lin, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E694 - E694
  • [8] Daily Dose Evaluation Utilizing In-Room Computed Tomography Positioning System for Prostate Cancer Treatment in Proton Therapy
    Sato, Y.
    Maeda, Y.
    Minami, H.
    Yasukawa, Y.
    Yamamoto, K.
    Tamamura, H.
    Shibata, S.
    Bou, S.
    Sasaki, M.
    Tameshige, Y.
    Ooto, H.
    Kasahara, S.
    Shimizu, Y.
    Saga, Y.
    Omoya, A.
    Saito, M.
    Aoyama, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E244 - E245
  • [9] Design of a proton computed tomography system for applications in proton radiation therapy
    Schulte, R
    Bashkirov, V
    Li, TF
    Liang, JZ
    Mueller, K
    Heimann, J
    Johnson, LR
    Keeney, B
    Sadrozinski, HFW
    Seiden, A
    Williams, DC
    Zhang, L
    Li, Z
    Peggs, S
    Satogata, T
    Woody, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1579 - 1583
  • [10] Tomographic images by proton Computed Tomography system for proton therapy applications
    Sipala, Valeria
    Bruzzi, Mara
    Brianzi, Mirko
    Bucciolini, Marta
    Cirrone, Giuseppe Antonio Pablo
    Civinini, Carlo
    Cuttone, Giacomo
    Lo Presti, Domenico
    Pallotta, Stefania
    Randazzo, Nunzio
    Romano, Francesco
    Scaringella, Monica
    Stancampiano, Concetta
    Talamonti, Cinzia
    Tesi, Mauro
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3505 - 3507