Intraocular lens power calculation: angle κ and ocular biomechanics

被引:3
|
作者
Marques, Joao Heitor [1 ]
Baptista, Pedro Manuel [1 ,2 ]
Ribeiro, Bruno [1 ]
Meneres, Pedro [1 ,2 ]
Beirao, Joao Melo [1 ,2 ]
机构
[1] Ctr Hosp Univ Porto, Serv Oftalmol, Porto, Portugal
[2] Univ Porto, Inst Ciencias Biomed Abel Salazar, Porto, Portugal
来源
关键词
ORBSCAN-II; ACCURACY; ERROR; AGE;
D O I
10.1097/j.jcrs.0000000000001362
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the effect of ocular biomechanics on the prediction error of intraocular lens (IOL) power calculation. Setting: Centro Hospitalar Universit & aacute;rio do Porto, Porto, Portugal. Design: Prospective longitudinal study. Methods: This study included 67 subjects. Before cataract surgery subjects underwent biometry with IOLMaster 700 and biomechanical analysis with Corvis Scheimpflug technology. The targeted spherical equivalent was calculated with SRK-T and Barrett Universal II. Associations between prediction error (PE), absolute prediction error (AE), and biometric and biomechanical parameters were performed with stepwise multivariate linear correlation analysis. Results: Using the SRKT formula, there was association between PE and Corvis Biomechanical Index (CBI, B = -0.531, P = .011) and between AE and the horizontal offset between the center of the pupil and the visual axis (angle kappa, B = -0.274, P = .007). Considering the Barret Universal II formula, PE was independently associated with anterior chamber depth (B = -0.279, P = .021) and CBI (B = -0.520, P = .013) and AE was associated with angle kappa (B = -0.370, P = .007). Conclusions: A large angle kappa may reduce the predictability of IOL power calculation. Ocular biomechanics likely influence the refractive outcomes after IOL implantation. This study showed that eyes with softer corneal biomechanics had more myopic PE. This may relate to anteriorization of the effective lens position. Dynamic measurements may be the way to progress into future formulas.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 50 条
  • [1] Intraocular lens power calculation: angle κ and ocular biomechanics
    Marques, Joao Heitor
    Baptista, Pedro Manuel
    Ribeiro, Bruno
    Meneres, Pedro
    Beirao, Joao Melo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (08): : 895 - 896
  • [2] Comment on: Intraocular lens power calculation: angle k and ocular biomechanics
    Wallerstein, Avi
    Ridgway, Chelsea
    Gauvin, Mathieu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (08): : 896 - 896
  • [3] Intraocular lens power calculation in primary angle closure
    Campos-Moller, Xavier
    Ahmed, Iqbal Ike K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 (08): : 663 - 665
  • [4] Effects of intraocular pressure change on intraocular lens power calculation in primary open-angle glaucoma and ocular hypertension
    Chirapapaisan, Chareenun
    Eiamsamarng, Akarawit
    Chirapapaisan, Niphon
    Raksong, Wara
    Sakiyalak, Darin
    Koodkaew, Sunisa
    Subunnasenee, Audcharawadee
    PLOS ONE, 2024, 19 (06):
  • [5] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [6] Influence of Pilocarpine Eyedrops on the Ocular Biometric Parameters and Intraocular Lens Power Calculation
    Gao, Ruxin
    Liu, Jinkun
    Zhou, Xiaojie
    Huang, Luping
    Huang, Weiyi
    Xue, Yingying
    Wang, Fei
    Gong, Songjian
    Wu, Renyi
    Wang, Yuhong
    JOURNAL OF OPHTHALMOLOGY, 2023, 2023
  • [7] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [8] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [9] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736
  • [10] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482