Experimental study on eccentric compression of the prefabricated columns with a new type of column-column connection node

被引:0
|
作者
He, Zongyuan [1 ,2 ]
Deng, Zhiheng [1 ,2 ,3 ]
Hu, Shaowei [1 ,2 ]
Liang, Xiaoqin [2 ,3 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Minist Educ, Nanning 530004, Peoples R China
[3] Nanning Univ, Coll Architecture & Civil Engn, Nanning 530200, Peoples R China
基金
中国国家自然科学基金;
关键词
Adhesive potted rebar lap joint; Prefabricated columns; Column-column node; Eccentric compression experiment; Bearing capacity; CONCRETE COLUMNS; BEHAVIOR; JOINTS; CONSTRUCTION; PERFORMANCE; BEAMS; BARS; BOND;
D O I
10.1016/j.istruc.2024.107239
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An assembled building is defined by a construction methodology wherein prefabricated components are fabricated off-site and subsequently assembled at the construction site. This methodology confers cost efficiency, expedites construction timelines, and enhances the quality of the prefabricated components. Furthermore, it mitigates a range of environmental concerns inherent to conventional poured-in-place construction methods. This paper introduces a novel assembled column-column connection node that utilizes a new adhesive potted rebar lap joint. The research was divided into two principal components. Firstly, 18 specimens of adhesive potted rebar lap joints were tested under tension, with the lap length being the variable parameter. Secondly, eccentric compression experiments were conducted on one poured-in-place column and six assembled columns, varying parameters such as stirrup configuration and the length of the post-poured section. The failure modes of the columns, as well as their bearing capacities, deflection, rebar strains, and concrete strains, were analyzed and recorded. The test results revealed the existence of two different failure modes in the tensile tests of adhesive potted rebar lap joints. It was found that the reasonable lap length of the specimen should be no less than 14 times the diameter of the rebar (d). Eq. (15) was employed to estimate the suitable lap length for specimens with different sleeve and rebar diameters. In the failure sections of the prefabricated columns, all failures occurred outside the nodes. Moreover, the mechanical properties of small eccentrically compressed columns were comparable to those of the poured-in-place column. The use of spiral stirrups enhances the bearing capacity of the specimen, and an increase in the length of the post-poured section corresponds to a greater bearing capacity. The lateral deflection of the poured-in-place column generally follows a sinusoidal curve, while the lateral deflection of prefabricated columns in the later stages of loading does not exhibit a sinusoidal pattern. Both align with the assumption of a flat section. The stress performance of adhesive potted rebar lap joints in eccentric columns meets the strength requirements. The inclusion of tenons minimally affects the stress distribution in the node, fulfilling construction specifications. The stress performance of the assembled column nodes is reliable. The proposed adhesive potted rebar lap joint technology, along with the novel prefabricated column-column node, provides significant insights into engineering design and construction applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Experimental study on seismic performance of composite structure of steel column-integrated prefabricated concrete wall with different connection types
    Chen W.
    Tao Z.
    Yang Y.
    Bao W.
    Li Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (11): : 89 - 98
  • [42] Experimental Study on Axial Compression of FRP Confined Concrete Column
    Han, Yangyang
    Zhang, Hao
    Li, YaQin
    Yao, Jia
    Hu, Xiaoping
    ADVANCED BUILDING MATERIALS AND STRUCTURAL ENGINEERING, 2012, 461 : 682 - +
  • [43] Experimental and numerical investigation on axial compression behaviour of prefabricated ECC shell-reinforced concrete column
    Ding, Mengjia
    Xu, Weibing
    Wang, Jin
    Chen, Yanjiang
    Zhou, Daxing
    Hou, Liqun
    Sun, Yulong
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 21
  • [44] Experimental study on seismic behavior of glulam columns with column-shoes
    Xie, Qifang
    Zhang, Yi
    Wu, Yajie
    Zhang, Lipeng
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (12): : 223 - 232
  • [45] SEPARATION EFFICIENCY VERSUS COLUMN LENGTH . AN EXPERIMENTAL STUDY WITH CAPILLARY COLUMNS
    GROB, K
    GROB, G
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1969, 7 (08) : 515 - &
  • [46] Experimental and numerical investigation of prefabricated prestressed vertical steel strand core tube flange column connection joint
    Zhang Yan-xia
    Huang Zhe-wen
    Li Yang-long
    Jin Bo-wen
    Cheng Xiao-tian
    Cheng Meng-yao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 190
  • [47] Experimental investigations on prefabricated interlocking prestressed tendon composite joint and its application to beam-column connection
    Ding, Yingnan
    Xu, Weibing
    Wang, Jin
    Chen, Yanjiang
    Du, Xiuli
    Shen, Botan
    Zhao, Zhuo
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [48] Experimental study on beam-to-column clip angle bolted connection
    Natesan, Vijayakumar
    Madhavan, Mahendrakumar
    THIN-WALLED STRUCTURES, 2019, 141 : 540 - 553
  • [49] Experimental Study and Theoretical Analysis on the Increasing Beam and Removing Column Connection
    Chen Zhihua
    Lu Zhengran
    Wang Xiaodun
    ICTAS 2009: PROCEEDINGS OF SHANGHAI INTERNATIONAL CONFERENCE ON TECHNOLOGY OF ARCHITECTURE AND STRUCTURE, PT I, 2009, : 540 - 549
  • [50] Behavior of new bolt-welded joint of CFST column with imperfection under eccentric compression
    Yu, Peng
    Peng, Minggui
    Yun, Weijing
    Guo, Xiao
    STRUCTURES, 2025, 71