Experimental study on eccentric compression of the prefabricated columns with a new type of column-column connection node

被引:0
|
作者
He, Zongyuan [1 ,2 ]
Deng, Zhiheng [1 ,2 ,3 ]
Hu, Shaowei [1 ,2 ]
Liang, Xiaoqin [2 ,3 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Minist Educ, Nanning 530004, Peoples R China
[3] Nanning Univ, Coll Architecture & Civil Engn, Nanning 530200, Peoples R China
基金
中国国家自然科学基金;
关键词
Adhesive potted rebar lap joint; Prefabricated columns; Column-column node; Eccentric compression experiment; Bearing capacity; CONCRETE COLUMNS; BEHAVIOR; JOINTS; CONSTRUCTION; PERFORMANCE; BEAMS; BARS; BOND;
D O I
10.1016/j.istruc.2024.107239
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An assembled building is defined by a construction methodology wherein prefabricated components are fabricated off-site and subsequently assembled at the construction site. This methodology confers cost efficiency, expedites construction timelines, and enhances the quality of the prefabricated components. Furthermore, it mitigates a range of environmental concerns inherent to conventional poured-in-place construction methods. This paper introduces a novel assembled column-column connection node that utilizes a new adhesive potted rebar lap joint. The research was divided into two principal components. Firstly, 18 specimens of adhesive potted rebar lap joints were tested under tension, with the lap length being the variable parameter. Secondly, eccentric compression experiments were conducted on one poured-in-place column and six assembled columns, varying parameters such as stirrup configuration and the length of the post-poured section. The failure modes of the columns, as well as their bearing capacities, deflection, rebar strains, and concrete strains, were analyzed and recorded. The test results revealed the existence of two different failure modes in the tensile tests of adhesive potted rebar lap joints. It was found that the reasonable lap length of the specimen should be no less than 14 times the diameter of the rebar (d). Eq. (15) was employed to estimate the suitable lap length for specimens with different sleeve and rebar diameters. In the failure sections of the prefabricated columns, all failures occurred outside the nodes. Moreover, the mechanical properties of small eccentrically compressed columns were comparable to those of the poured-in-place column. The use of spiral stirrups enhances the bearing capacity of the specimen, and an increase in the length of the post-poured section corresponds to a greater bearing capacity. The lateral deflection of the poured-in-place column generally follows a sinusoidal curve, while the lateral deflection of prefabricated columns in the later stages of loading does not exhibit a sinusoidal pattern. Both align with the assumption of a flat section. The stress performance of adhesive potted rebar lap joints in eccentric columns meets the strength requirements. The inclusion of tenons minimally affects the stress distribution in the node, fulfilling construction specifications. The stress performance of the assembled column nodes is reliable. The proposed adhesive potted rebar lap joint technology, along with the novel prefabricated column-column node, provides significant insights into engineering design and construction applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF A NEW PRECAST CONCRETE BEAM TO COLUMN CONNECTION
    Yu, Jianbing
    Guo, Zhengxing
    Guan, Dongzhi
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 1305 - 1312
  • [22] Experimental Study for the Strength with CFRP in Small Eccentric RC Column
    Zheng, Liu
    Jun, Sun
    Yan, Tao
    Qian, Li
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 3064 - 3069
  • [23] Experimental Study of Corner Slab-Column Connection
    Cheng, Min-Yuan
    Giduquio, Marnie B.
    ACI STRUCTURAL JOURNAL, 2014, 111 (05) : 1123 - 1133
  • [24] Experimental study on seismic behaviors of precast concrete columns with column shoes-anchor bolt connection
    Zhang C.
    Tian C.
    Zhao Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 : 265 - 275
  • [25] Experimental study and numerical simulation of a new prefabricated SRC column to steel beam composite joint
    Yu, SuJian
    Wu, Chenglong
    Zhou, Fei
    Wang, Pengfei
    Zhao, Kaichang
    Liu, Jiming
    STRUCTURES, 2020, 27 : 999 - 1010
  • [26] Experimental study on seismic performances of a new type of fabricated semi-rigid beam-to-column connection
    Ding, Kewei
    Liu, Jianhua
    Ma, Wei
    Liu, Yunlin
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2021, 54 (04): : 1 - 7
  • [27] Experimental research on RC eccentric compression column strengthened with the combination of CFRP and angle steel
    Lu, Yiyan
    Tong, Guangbing
    Zhang, Haojun
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2006, 27 (01): : 106 - 111
  • [28] Design and Mechanical Performance Analysis of a New Type of Column-Column-Beam Prefabricated Steel Frame Joint
    Zhang, Zhiwei
    Wang, Huajie
    Qian, Hongliang
    Gao, Kaifeng
    An, Baiping
    Feng, Fan
    STRUCTURAL ENGINEERING INTERNATIONAL, 2021, 31 (03) : 418 - 426
  • [29] Experimental and Analytical Study of Fully Prefabricated Damage-Tolerant Beam to Column Connection for Earthquake-Resilient Frame
    Deng, Kailai
    Zheng, Di
    Yang, Cheng
    Xu, Tengfei
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (03)
  • [30] Study on the Simulated Destruction Test of the Reinforced Concrete Column under Eccentric Compression
    Zhang Li
    Zhang Qian
    Xue Yu-feng
    2011 AASRI CONFERENCE ON APPLIED INFORMATION TECHNOLOGY (AASRI-AIT 2011), VOL 2, 2011, : 227 - 229