Experimental study on eccentric compression of the prefabricated columns with a new type of column-column connection node

被引:0
|
作者
He, Zongyuan [1 ,2 ]
Deng, Zhiheng [1 ,2 ,3 ]
Hu, Shaowei [1 ,2 ]
Liang, Xiaoqin [2 ,3 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Minist Educ, Nanning 530004, Peoples R China
[3] Nanning Univ, Coll Architecture & Civil Engn, Nanning 530200, Peoples R China
基金
中国国家自然科学基金;
关键词
Adhesive potted rebar lap joint; Prefabricated columns; Column-column node; Eccentric compression experiment; Bearing capacity; CONCRETE COLUMNS; BEHAVIOR; JOINTS; CONSTRUCTION; PERFORMANCE; BEAMS; BARS; BOND;
D O I
10.1016/j.istruc.2024.107239
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An assembled building is defined by a construction methodology wherein prefabricated components are fabricated off-site and subsequently assembled at the construction site. This methodology confers cost efficiency, expedites construction timelines, and enhances the quality of the prefabricated components. Furthermore, it mitigates a range of environmental concerns inherent to conventional poured-in-place construction methods. This paper introduces a novel assembled column-column connection node that utilizes a new adhesive potted rebar lap joint. The research was divided into two principal components. Firstly, 18 specimens of adhesive potted rebar lap joints were tested under tension, with the lap length being the variable parameter. Secondly, eccentric compression experiments were conducted on one poured-in-place column and six assembled columns, varying parameters such as stirrup configuration and the length of the post-poured section. The failure modes of the columns, as well as their bearing capacities, deflection, rebar strains, and concrete strains, were analyzed and recorded. The test results revealed the existence of two different failure modes in the tensile tests of adhesive potted rebar lap joints. It was found that the reasonable lap length of the specimen should be no less than 14 times the diameter of the rebar (d). Eq. (15) was employed to estimate the suitable lap length for specimens with different sleeve and rebar diameters. In the failure sections of the prefabricated columns, all failures occurred outside the nodes. Moreover, the mechanical properties of small eccentrically compressed columns were comparable to those of the poured-in-place column. The use of spiral stirrups enhances the bearing capacity of the specimen, and an increase in the length of the post-poured section corresponds to a greater bearing capacity. The lateral deflection of the poured-in-place column generally follows a sinusoidal curve, while the lateral deflection of prefabricated columns in the later stages of loading does not exhibit a sinusoidal pattern. Both align with the assumption of a flat section. The stress performance of adhesive potted rebar lap joints in eccentric columns meets the strength requirements. The inclusion of tenons minimally affects the stress distribution in the node, fulfilling construction specifications. The stress performance of the assembled column nodes is reliable. The proposed adhesive potted rebar lap joint technology, along with the novel prefabricated column-column node, provides significant insights into engineering design and construction applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Experimental study on the seismic performance of a prefabricated steel column-column connection
    Yang, Yong
    Xu, Longkang
    Feng, Shiqiang
    Sun, Dongde
    Xue, Yicong
    Yu, Yunlong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [2] Experimental study on seismic performance of prefabricated column-column connection with prestressed steel strands
    Zhang, Ailin
    Li, Xinxia
    Yang, Zheng
    Zhang, Yanxia
    Cheng, Mengyao
    JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [3] Axial compression behaviour of bolted-flange composite column-column connection
    Shehab, Bashar A.
    Ekmekyapar, Talha
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2022, 175 (11) : 877 - 889
  • [4] Seismic vulnerability of prefabricated reinforced concrete frame structure based on local outsource steel tube bolted column-column connection
    Zhang, Jiaolei
    Li, Jin
    Liang, Qi
    Li, Shufeng
    Yuan, Dawei
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (04) : 784 - 796
  • [5] Manuscript title: Experimental investigations of concrete-filled double skin steel tube column-column grouted connection under axial compression
    Wang, Zhanwen
    Chen, Jianwei
    Zhang, Rui
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 453
  • [6] Experimental study on eccentric compression performance of column with hybrid of GFRP and steel bars
    Wang T.
    Li L.
    Zhou Z.
    Cao Y.
    Yin J.
    Bai Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 248 - 255
  • [7] Experimental study on eccentric compression performance of sleeve grouting connection concrete-filled steel tube composite column
    Zhang R.
    Chen J.
    Wu S.
    Che W.
    Su Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 239 - 247
  • [8] Experimental and Numerical Analyses on the Seismic Performance of a Novel Precast Concrete Column-column Joints with Bolted End-plate Connection
    Zhaoqiang Wang
    Feng Xiong
    Jiang Chen
    Xulong Zhu
    KSCE Journal of Civil Engineering, 2022, 26 : 4746 - 4759
  • [9] Experimental and Numerical Analyses on the Seismic Performance of a Novel Precast Concrete Column-column Joints with Bolted End-plate Connection
    Wang, Zhaoqiang
    Xiong, Feng
    Chen, Jiang
    Zhu, Xulong
    KSCE JOURNAL OF CIVIL ENGINEERING, 2022, 26 (11) : 4746 - 4759
  • [10] Experimental study on seismic performance of prefabricated beam to column rotation friction energy dissipation connection
    Chen Y.
    Chen C.
    Xu Z.-F.
    Yu W.-H.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2022, 35 (01): : 45 - 54