Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study

被引:0
|
作者
Xin, Lin [1 ]
Zhuo, Weihai [1 ]
Liu, Qian [2 ]
Xie, Tianwu [1 ,3 ]
Zaidi, Habib [3 ,4 ,5 ,6 ]
机构
[1] Fudan Univ, Inst Radiat Med, 2094 Xietu Rd, Shanghai 200032, Peoples R China
[2] Hainan Univ, Sch Biomed Engn, Haikou 570100, Peoples R China
[3] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[4] Univ Geneva, Geneva Neurosci Ctr, Geneva, Switzerland
[5] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[6] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2024年 / 34卷 / 03期
关键词
Triple-source; Saddle curve CT; Photon counting CT; Exact reconstruction; Simulation study; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; SPECTRAL CT; ALGORITHM; ANGIOGRAPHY; PERFORMANCE; DETECTORS; IMPACT;
D O I
10.1016/j.zemedi.2022.10.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The most common detector material in the PC CT system, cannot achieve the best performance at a relatively higher photon flux rate. In the reconstruction view, the most commonly used filtered back projection, is not able to provide sufficient reconstructed image quality in spectral computed tomography (CT). Developing a triple-source saddle-curve cone-beam photon counting CT image reconstruction method can improve the temporal resolution. Methods: Triple-source saddle-curve cone-beam trajectory was rearranged into four trajectory sets for simulation and reconstruction. Projection images in different energy bins were simulated by forward projection and photon counting CT respond model simulation. After simulation, the object was reconstructed using Katsevich's theory after photon counts correction using the pseudo inverse of photon counting CT response matrix. The material decomposition can be performed based on images in different energy bins. Results: Root mean square error (RMSE) and structural similarity index (SSIM) are calculated to quantify the image quality of reconstruction images. Compared with FDK images, the RMSE for the triple-source image was improved by 27%, 21%, 14%, 8%, and 6% for the reconstrued image of 20-33, 33-47, 47-58, 58-69, 69-80 keV energy bin. The SSIM was improved by 1.031%, 0.665%, 0.396%, 0.235%, 0.174% for corresponding energy bin. The decomposition image based on corrected images shows improved RMSE and SSIM, each by 33.861% and 0.345%. SSIM of corrected decomposition image of iodine reaches 99.415% of the original image. Conclusions: A new Triple-source saddle-curve cone-beam PC CT image reconstruction method was developed in this work. The exact reconstruction of the triple-source saddle-curve improved both the image quality and temporal resolution.
引用
收藏
页码:408 / 418
页数:11
相关论文
共 50 条
  • [41] Statistical Cone-Beam CT Image Reconstruction using the Cell Broadband Engine
    Knaup, Michael
    Kalender, Willi A.
    Kachelriess, Marc
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2837 - 2840
  • [42] Image reconstruction with a shift-variant filtration in circular cone-beam CT
    Yu, LF
    Pan, XC
    Pelizzari, CA
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2004, 14 (05) : 213 - 221
  • [43] Few-view cone-beam CT reconstruction with deformed prior image
    Zhang, Hua
    Ouyang, Luo
    Huang, Jing
    Ma, Jianhua
    Chen, Wufan
    Wang, Jing
    MEDICAL PHYSICS, 2014, 41 (12)
  • [44] Chord-based image reconstruction in cone-beam CT with a curved detector
    Zuo, Nianming
    Xia, Dan
    Zou, Yu
    Jiang, Tianzi
    Pan, Xiao-Chuan
    MEDICAL PHYSICS, 2006, 33 (10) : 3743 - 3757
  • [45] Preliminary Study of Optimization-Based Image Reconstruction from Dental Cone-beam CT Data
    Zhang, Z.
    Han, X.
    Bian, J.
    Kusnoto, B.
    Sidky, E. Y.
    Pan, X.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [46] A new approximate algorithm for image reconstruction in cone-beam spiral CT at small cone-angles
    Schaller, S
    Flohr, T
    Steffen, P
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1703 - 1709
  • [47] OSCaR: An open-source cone-beam CT reconstruction tool for imaging research
    Rezvani, N.
    Aruliah, D.
    Jackson, K.
    Moseley, D.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2341 - 2341
  • [48] Exact FBP reconstruction for a cone-beam CT scanner with independent rotations of the source and the detector
    Rit, S.
    Clackdoyle, R.
    Keuschnigg, P.
    Steininger, P.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S198 - S199
  • [49] A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5497 - 5508
  • [50] RESEARCH ON PARALLEL CONE-BEAM CT IMAGE RECONSTRUCTION ON CUDA-ENABLED GPU
    Sun, Yigang
    Sun, Xiuyu
    Zhang, Hongying
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 4501 - 4504