Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study

被引:0
|
作者
Xin, Lin [1 ]
Zhuo, Weihai [1 ]
Liu, Qian [2 ]
Xie, Tianwu [1 ,3 ]
Zaidi, Habib [3 ,4 ,5 ,6 ]
机构
[1] Fudan Univ, Inst Radiat Med, 2094 Xietu Rd, Shanghai 200032, Peoples R China
[2] Hainan Univ, Sch Biomed Engn, Haikou 570100, Peoples R China
[3] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[4] Univ Geneva, Geneva Neurosci Ctr, Geneva, Switzerland
[5] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[6] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2024年 / 34卷 / 03期
关键词
Triple-source; Saddle curve CT; Photon counting CT; Exact reconstruction; Simulation study; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; SPECTRAL CT; ALGORITHM; ANGIOGRAPHY; PERFORMANCE; DETECTORS; IMPACT;
D O I
10.1016/j.zemedi.2022.10.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The most common detector material in the PC CT system, cannot achieve the best performance at a relatively higher photon flux rate. In the reconstruction view, the most commonly used filtered back projection, is not able to provide sufficient reconstructed image quality in spectral computed tomography (CT). Developing a triple-source saddle-curve cone-beam photon counting CT image reconstruction method can improve the temporal resolution. Methods: Triple-source saddle-curve cone-beam trajectory was rearranged into four trajectory sets for simulation and reconstruction. Projection images in different energy bins were simulated by forward projection and photon counting CT respond model simulation. After simulation, the object was reconstructed using Katsevich's theory after photon counts correction using the pseudo inverse of photon counting CT response matrix. The material decomposition can be performed based on images in different energy bins. Results: Root mean square error (RMSE) and structural similarity index (SSIM) are calculated to quantify the image quality of reconstruction images. Compared with FDK images, the RMSE for the triple-source image was improved by 27%, 21%, 14%, 8%, and 6% for the reconstrued image of 20-33, 33-47, 47-58, 58-69, 69-80 keV energy bin. The SSIM was improved by 1.031%, 0.665%, 0.396%, 0.235%, 0.174% for corresponding energy bin. The decomposition image based on corrected images shows improved RMSE and SSIM, each by 33.861% and 0.345%. SSIM of corrected decomposition image of iodine reaches 99.415% of the original image. Conclusions: A new Triple-source saddle-curve cone-beam PC CT image reconstruction method was developed in this work. The exact reconstruction of the triple-source saddle-curve improved both the image quality and temporal resolution.
引用
收藏
页码:408 / 418
页数:11
相关论文
共 50 条
  • [31] Minimum detection window and inter-helix PI-line with triple-source helical cone-beam scanning
    Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China
    不详
    不详
    SPIE, 1600, 599-610 (2004):
  • [32] Fast algorithm for calculating the radiological path in cone-beam ct image reconstruction
    Li, Ruru
    Pan, Jinxiao
    Kong, Huihua
    Journal of Information and Computational Science, 2010, 7 (14): : 3125 - 3132
  • [33] Reconstruction of a Cone-Beam CT Image Via Forward Iterative Projection Matching
    Brock, R.
    Docef, A.
    Murphy, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3112 - +
  • [34] Reconstruction of a cone-beam CT image via forward iterative projection matching
    Brock, R. Scott
    Docef, Alen
    Murphy, Martin J.
    MEDICAL PHYSICS, 2010, 37 (12) : 6212 - 6220
  • [35] An Image Reconstruction Strategy for Truncated Projections of Planar Object in Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Jiang, Hua
    Chen, Siyu
    Cui, Jinxian
    Cong, Dan
    Tian, Ying
    2015 12TH INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND KNOWLEDGE DISCOVERY (FSKD), 2015, : 1113 - 1117
  • [36] Image reconstruction in cone-beam CT with a spherical detector using the BPF algorithm
    Zuo, Nianming
    Zou, Yu
    Jiang, Tianzi
    Pan, Xiaochuan
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [37] Image Reconstruction Using OS-EM Method in Cone-beam CT
    Dong, Baoyu
    2008 IEEE INTERNATIONAL SYMPOSIUM ON KNOWLEDGE ACQUISITION AND MODELING WORKSHOP PROCEEDINGS, VOLS 1 AND 2, 2008, : 108 - 111
  • [38] Development of a Benchtop Photon Counting Cone-Beam CT System with a Translate-Rotate Geometry
    Bader, A. M.
    Makeev, A.
    Glick, S. J.
    Ghammraoui, B.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [39] An improved exact FBP algorithm for image reconstruction in cone-beam helical CT
    Ma, Jianhua
    Chen, Wufan
    2006 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND SECURITY, PTS 1 AND 2, PROCEEDINGS, 2006, : 1635 - 1640
  • [40] Exact image reconstruction in reverse helical cone-beam CT for radiation therapy
    Cho, S.
    Xia, D.
    Pelizzari, C.
    Pan, X.
    MEDICAL PHYSICS, 2007, 34 (06) : 2633 - 2634