Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study

被引:0
|
作者
Xin, Lin [1 ]
Zhuo, Weihai [1 ]
Liu, Qian [2 ]
Xie, Tianwu [1 ,3 ]
Zaidi, Habib [3 ,4 ,5 ,6 ]
机构
[1] Fudan Univ, Inst Radiat Med, 2094 Xietu Rd, Shanghai 200032, Peoples R China
[2] Hainan Univ, Sch Biomed Engn, Haikou 570100, Peoples R China
[3] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[4] Univ Geneva, Geneva Neurosci Ctr, Geneva, Switzerland
[5] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[6] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2024年 / 34卷 / 03期
关键词
Triple-source; Saddle curve CT; Photon counting CT; Exact reconstruction; Simulation study; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; SPECTRAL CT; ALGORITHM; ANGIOGRAPHY; PERFORMANCE; DETECTORS; IMPACT;
D O I
10.1016/j.zemedi.2022.10.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The most common detector material in the PC CT system, cannot achieve the best performance at a relatively higher photon flux rate. In the reconstruction view, the most commonly used filtered back projection, is not able to provide sufficient reconstructed image quality in spectral computed tomography (CT). Developing a triple-source saddle-curve cone-beam photon counting CT image reconstruction method can improve the temporal resolution. Methods: Triple-source saddle-curve cone-beam trajectory was rearranged into four trajectory sets for simulation and reconstruction. Projection images in different energy bins were simulated by forward projection and photon counting CT respond model simulation. After simulation, the object was reconstructed using Katsevich's theory after photon counts correction using the pseudo inverse of photon counting CT response matrix. The material decomposition can be performed based on images in different energy bins. Results: Root mean square error (RMSE) and structural similarity index (SSIM) are calculated to quantify the image quality of reconstruction images. Compared with FDK images, the RMSE for the triple-source image was improved by 27%, 21%, 14%, 8%, and 6% for the reconstrued image of 20-33, 33-47, 47-58, 58-69, 69-80 keV energy bin. The SSIM was improved by 1.031%, 0.665%, 0.396%, 0.235%, 0.174% for corresponding energy bin. The decomposition image based on corrected images shows improved RMSE and SSIM, each by 33.861% and 0.345%. SSIM of corrected decomposition image of iodine reaches 99.415% of the original image. Conclusions: A new Triple-source saddle-curve cone-beam PC CT image reconstruction method was developed in this work. The exact reconstruction of the triple-source saddle-curve improved both the image quality and temporal resolution.
引用
收藏
页码:408 / 418
页数:11
相关论文
共 50 条
  • [1] Exact image reconstruction with triple-source saddle-curve cone-beam scanning
    Lu, Yang
    Zhao, Jun
    Wang, Ge
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10): : 2971 - 2991
  • [2] Exact image reconstruction for triple-source cone-beam CT along saddle trajectories
    Lu, Yang
    Zhao, Jun
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [3] A reconstruction algorithm for triple-source helical cone-beam CT
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1875 - 1878
  • [4] Simulation studies for triple-source helical cone-beam CT
    Zhao, Jun
    Jin, Yannan
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [5] An exact reconstruction algorithm for triple-source helical cone-beam CT
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (03) : 191 - 206
  • [6] Exact reconstruction for unequally spaced triple-source helical cone-beam CT
    Jin, Yannan
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [7] A Filtered Backprojection Algorithm for Triple-Source Helical Cone-Beam CT
    Zhao, Jun
    Jin, Yannan
    Lu, Yang
    Wang, Ge
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) : 384 - 393
  • [8] Fast Exact/Quasi-Exact FBP Algorithms for Triple-Source Helical Cone-Beam CT
    Lu, Yang
    Katsevich, Alexander
    Zhao, Jun
    Yu, Hengyong
    Wang, Ge
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) : 756 - 770
  • [9] Image Reconstruction of Arc Cone-Beam CT with Reprojection: A preliminary study
    Lo, Shih-Chung B.
    Freedman, Matthew T.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [10] Cone-Beam CT Reconstruction with Deformed Prior Image
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527