Field investigation on thermal comfort of metro passengers in hot summer and warm winter zone of China: A case study in Guangzhou

被引:5
|
作者
Chen, Zihao [1 ]
Xie, Xinze [1 ]
Hu, Huiming [1 ]
Zhou, Xuanxuan [1 ]
Yang, Yadie [4 ]
Song, Wenfang [1 ,2 ,3 ]
Luh, Ding Bang [1 ]
Li, Xin [1 ]
机构
[1] Guangdong Univ Technol, Sch Art & Design, Guangzhou 510000, Peoples R China
[2] Guangdong Univ Technol, Lab Human Thermophysiol & Ergon, Guangzhou 510000, Peoples R China
[3] Guangdong Univ Technol, Smart Med Innovat Technol Ctr, Guangzhou 510000, Peoples R China
[4] Hong Kong Polytech Univ, Sch Fash & Text, Hunghom, Hong Kong, Peoples R China
关键词
Field study; Thermal comfort; Metro environment; Initial metabolic rates; METABOLIC-RATE; VENTILATION; TRANSITION; TEMPERATURE; ENVIRONMENT; TRANSPORT; RESPONSES; STATIONS; GENDER;
D O I
10.1016/j.enbuild.2024.114633
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the hot summer and warm winter zone of China, the metro thermal environments and passengers' thermal comfort were rarely examined, influencing factors such as commuter hours and individual factors were less discussed, and understanding them was beneficial for improving human thermal comfort and saving energy. In this study, a field study was undertaken in Guangzhou located in the region during the summer of 2023. Four metro stations and three metro lines were selected, a total of 1481 valid questionnaires were gathered. The results revealed that the metro thermal environment was highly commendable during the hot summer months, with a thermal acceptability vote (TAV) ranging from 81 % to 89 % across the entrance (ET), concourse (CC), platform (PF), and carriage (CR). Furthermore, the upper limit of the 80 % acceptance range for operative temperature (T-op) was 29.11 degrees C in the ET, 27.82 degrees C in the CC, 29.13 degrees C in the PF, and 28.44 degrees C in the CR. These temperatures exceed the actual mean T-op values in these locations, indicating there is a significant potential for energy savings in metro environments. The upper limits of T-op values for passengers with low, medium and high metabolic rates are 30.34 degrees C, 28.92 degrees C, and 28.25 degrees C, respectively. Thermal sensation votes (TSVs) fell well within the comfort zone specified in ISO 7730 (-0.7 < PMV < 0.7) during both peak and off-peak hours. No difference was found in TSVs between the two genders and among the different ages.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Thermal comfort of naturally ventilated buildings in hot summer/cold winter region, China
    Yang, Wei
    Zhang, Guoqiang
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 602 - 606
  • [22] Thermal comfort analysis in departure lounge at railway station in hot summer and cold winter zone
    School of Energy Science and Engineering, Central South University, Changsha 410083, China
    Tumu Jianzhu yu Huanjing Gongcheng, 2009, 5 (100-105):
  • [23] Carbon Emissions of Operation Stage of Residential Buildings in Hot Summer and Warm Winter Zone in China
    Lin, Lu
    Yin, Xiuqin
    Zhong, Sijie
    Lin, Ke
    Huang, Yaojie
    Feng, Weimin
    CARBON PEAK AND NEUTRALITY STRATEGIES OF THE CONSTRUCTION INDUSTRY (ICCREM 2022), 2022, : 227 - 235
  • [24] Integrating thermal perception and public space use - an experimental outdoor comfort study in cold winter-hot summer zone: Beijing, China
    Ma, Tong
    Zhang, Jian
    URBAN CLIMATE, 2024, 58
  • [25] A FIELD STUDY ON OUTDOOR THERMAL COMFORT OF CHANGSHA IN SUMMER, CHINA
    Liu, J.
    Zhou, J. L.
    Han, J.
    Zhang, G. Q.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 292 - 297
  • [26] A study of energy performance and audit of commercial mall in hot-summer/warm-winter climate zone in China
    Li Zhisheng
    Lin, Yaolin
    Liao Jiawen
    Liu Xuhong
    Wang Xiaoxia
    ENERGY EFFICIENCY, 2013, 6 (03) : 459 - 473
  • [27] A study of energy performance and audit of commercial mall in hot-summer/warm-winter climate zone in China
    Li Zhisheng
    Yaolin Lin
    Liao Jiawen
    Liu Xuhong
    Wang Xiaoxia
    Energy Efficiency, 2013, 6 : 459 - 473
  • [28] Field Study of Human Thermal Comfort and Thermal Adaptability during Summer and Winter in Beijing
    Cao, Bin
    Zhu, Yingxin
    Ouyang, Qin
    Zhou, Xiang
    Huang, Li
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1207 - 1216
  • [29] Comparison of Thermal Comfort in Different Subway Spaces in China's Hot Summer and Cold Winter Region: A Field Investigation Based on Subway Station Transition
    Zhang, Chi
    Xu, Shen
    Qi, Congyue
    Dai, Rui
    Mendis, Thushini
    Wang, Minghao
    BUILDINGS, 2025, 15 (05)
  • [30] Field study of human thermal comfort and thermal adaptability during the summer and winter in Beijing
    Cao, Bin
    Zhu, Yingxin
    Ouyang, Qin
    Zhou, Xiang
    Huang, Li
    ENERGY AND BUILDINGS, 2011, 43 (05) : 1051 - 1056