Cannulated compression screws with cable technique leads to a dramatic reduction in patella fracture fixation complications compared to tension band wiring

被引:0
|
作者
Poh, Jane Wenjin [1 ]
Li, Zongxian [2 ]
Koh, Don Thong Siang [2 ]
Tay, Kenny Xian Khing [2 ]
Goh, Seo Kiat [2 ]
Woo, Yew Lok [2 ]
Xia, Zhan [2 ]
机构
[1] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
[2] Singapore Gen Hosp, Dept Orthopaed Surg, Singapore, Singapore
关键词
Patella fracture; Tension band wiring; Cannulated compression screw; Clinical outcomes; Complications; BIOMECHANICAL EVALUATION; INTERNAL-FIXATION; OUTCOMES; VALIDITY; SCORE;
D O I
10.1007/s00402-024-05533-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe aim of this study was to compare the clinical, radiological and functional outcomes between cannulated compression screw with cable construct (CS) and tension band wiring (TBW) in transverse patella fractures.Materials and methodsA retrospective study was conducted on patients surgically treated for AO/OTA 34C1 or 34C2 transverse patella fractures with CS or TBW technique between January 2019 and January 2023. Clinical outcomes included complications related to the implant, wound and fracture at 6 months and 1 year, time to achieving full weight bearing status and early perioperative clinical outcomes. Radiological outcomes included the time to fracture heals and delayed union. Functional outcome measures using the Oxford Knee Scale, 36-short form questionnaire and the Bartlett Anterior Knee Score were assessed.Results73 patients were treated with CS (n = 33) or TBW (n = 40). TBW had higher complication rates: 25.0% (n = 10) required implant removal, 12.5% (n = 5) had wire breakage, 12.5% (n = 5) experienced fracture displacement while 52.5% (n = 21) experienced implant migration. In contrast, no CS patients had implant removals, wire breakage or fracture displacement and 3.0% (n = 1) experienced implant migration. At 1 day post-operatively, 87.9% (n = 29) CS group patients were able to ambulate as compared to the 55.0% (n = 22) of TBW patients. Furthermore, CS patients ambulated further distances at 11.8 +/- 10.6 m than the TBW group (6.4 +/- 7.4 m). The CS group (25.9 +/- 24.6 days) also achieved full weight bearing status faster than the TBW group (43.6 +/- 39.4 days). The time taken for the fracture to heal and functional outcomes were comparable among the two groups.ConclusionsThe CS technique demonstrated lower complications, in particular, no CS patient had implant removals, wire migration or fracture displacement. Additionally, CS technique showed a faster return to ambulation and time to achieving full weight bearing status.
引用
收藏
页码:4333 / 4341
页数:9
相关论文
共 50 条
  • [41] Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation
    Tien-Yu Yang
    Tsan-Wen Huang
    Po-Yao Chuang
    Kuo-Chin Huang
    BMC Musculoskeletal Disorders, 19
  • [42] Olecranon Osteotomy Fixation Following Distal Humerus Open Reduction and Internal Fixation: Clinical Results of Plate and Screws Versus Tension Band Wiring
    Haglin, Jack M.
    Lott, Ariana
    Kugelman, David N.
    Bird, Mackenzie
    Konda, Sanjit R.
    Tejwani, Nirmal C.
    Egol, Kenneth A.
    ORTHOPEDICS, 2021, 44 (01) : E107 - E113
  • [43] Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation
    Yang, Tien-Yu
    Huang, Tsan-Wen
    Chuang, Po-Yao
    Huang, Kuo-Chin
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [44] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Simon Thelen
    Johannes Schneppendahl
    Ralf Baumgärtner
    Christian Eichler
    Jürgen Koebke
    Marcel Betsch
    Mohssen Hakimi
    Joachim Windolf
    Michael Wild
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 311 - 317
  • [45] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Thelen, Simon
    Schneppendahl, Johannes
    Baumgaertner, Ralf
    Eichler, Christian
    Koebke, Juergen
    Betsch, Marcel
    Hakimi, Mohssen
    Windolf, Joachim
    Wild, Michael
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 311 - 317
  • [46] Comparison of Tension Band Wiring Method Applied with K-wire or Cannulated Screw in Mayo 2A Olecranon Fracture Fixation: A Biomechanical Study
    Kaya, Murat
    Ertem, Fatih
    DUZCE MEDICAL JOURNAL, 2022, 24 (02) : 152 - 156
  • [47] Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method
    Huang, Po-Hua
    Hsu, Chi-Hsiang
    Hsu, Shan-Ling
    Liu, Hao-Chen
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (01)
  • [48] Cerclage fixation without K-wires is associated with fewer complications and reoperations compared with tension band wiring in stable displaced olecranon fractures in elderly patients
    Wenger, Daniel
    Cornefjord, Gustav
    Rogmark, Cecilia
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2669 - 2676
  • [49] Cerclage fixation without K-wires is associated with fewer complications and reoperations compared with tension band wiring in stable displaced olecranon fractures in elderly patients
    Daniel Wenger
    Gustav Cornefjord
    Cecilia Rogmark
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 2669 - 2676
  • [50] Letter to the Editor regarding "Treatment of displaced fractures of the patella: Tension band wiring technique with the one-end or both-ends K-wire bending fixation method"
    Sinha, Nirmal Kumar
    Bhardwaj, Amit
    Rao, Ashutosh Sadashiva
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (03)