Cannulated compression screws with cable technique leads to a dramatic reduction in patella fracture fixation complications compared to tension band wiring

被引:0
|
作者
Poh, Jane Wenjin [1 ]
Li, Zongxian [2 ]
Koh, Don Thong Siang [2 ]
Tay, Kenny Xian Khing [2 ]
Goh, Seo Kiat [2 ]
Woo, Yew Lok [2 ]
Xia, Zhan [2 ]
机构
[1] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
[2] Singapore Gen Hosp, Dept Orthopaed Surg, Singapore, Singapore
关键词
Patella fracture; Tension band wiring; Cannulated compression screw; Clinical outcomes; Complications; BIOMECHANICAL EVALUATION; INTERNAL-FIXATION; OUTCOMES; VALIDITY; SCORE;
D O I
10.1007/s00402-024-05533-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe aim of this study was to compare the clinical, radiological and functional outcomes between cannulated compression screw with cable construct (CS) and tension band wiring (TBW) in transverse patella fractures.Materials and methodsA retrospective study was conducted on patients surgically treated for AO/OTA 34C1 or 34C2 transverse patella fractures with CS or TBW technique between January 2019 and January 2023. Clinical outcomes included complications related to the implant, wound and fracture at 6 months and 1 year, time to achieving full weight bearing status and early perioperative clinical outcomes. Radiological outcomes included the time to fracture heals and delayed union. Functional outcome measures using the Oxford Knee Scale, 36-short form questionnaire and the Bartlett Anterior Knee Score were assessed.Results73 patients were treated with CS (n = 33) or TBW (n = 40). TBW had higher complication rates: 25.0% (n = 10) required implant removal, 12.5% (n = 5) had wire breakage, 12.5% (n = 5) experienced fracture displacement while 52.5% (n = 21) experienced implant migration. In contrast, no CS patients had implant removals, wire breakage or fracture displacement and 3.0% (n = 1) experienced implant migration. At 1 day post-operatively, 87.9% (n = 29) CS group patients were able to ambulate as compared to the 55.0% (n = 22) of TBW patients. Furthermore, CS patients ambulated further distances at 11.8 +/- 10.6 m than the TBW group (6.4 +/- 7.4 m). The CS group (25.9 +/- 24.6 days) also achieved full weight bearing status faster than the TBW group (43.6 +/- 39.4 days). The time taken for the fracture to heal and functional outcomes were comparable among the two groups.ConclusionsThe CS technique demonstrated lower complications, in particular, no CS patient had implant removals, wire migration or fracture displacement. Additionally, CS technique showed a faster return to ambulation and time to achieving full weight bearing status.
引用
收藏
页码:4333 / 4341
页数:9
相关论文
共 50 条
  • [31] Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
    Lin, Tao
    Liu, Junbin
    Xiao, Baojun
    Fu, Dehao
    Yang, Shuhua
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [32] Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
    Tao Lin
    Junbin Liu
    Baojun Xiao
    Dehao Fu
    Shuhua Yang
    BMC Musculoskeletal Disorders, 16
  • [33] A Comparison of the Efficacy of Cannulated Screws against Modified Tension Band Wire in the Management of Slightly Displaced Fractures of the Patella: A Novel Technique
    Menekse, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (11) : 1696 - 1702
  • [34] Predictors of postoperative complications of tension band wiring techniques for patella fracture: A retrospective multicenter (TRON group) study
    Oyama, Hiroki
    Takegami, Yasuhiko
    Tokutake, Katsuhiro
    Murase, Fuminori
    Arakawa, Oki
    Oguchi, Takeshi
    Imagama, Shiro
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (08):
  • [35] A Tension-Band Wiring Technique for Direct Fixation of a Chaput Tubercle Fracture: Technical Note
    Yeo, Eui-Dong
    Jung, Ki-Jin
    Hong, Yong-Cheol
    Hong, Chang-Hwa
    Lee, Hong-Seop
    Won, Sung-Hun
    Yoon, Sung-Joon
    Kim, Sung-Hwan
    Ji, Jae-Young
    Lee, Dhong-Won
    Kim, Woo-Jong
    MEDICINA-LITHUANIA, 2022, 58 (08):
  • [36] Tension band wiring through double-cannulated screws as a new internal fixation method for treatment of olecranon fractures: a randomized comparative study
    Lu, Qi-feng
    Tang, Gen-ling
    Zhao, Xi-jiang
    Zhang, Wen-jie
    Guo, Shu-guang
    Wang, Hang-zhou
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (06) : 654 - 660
  • [37] Modified tension band wiring of patellar fracture as a technique to minimize postoperative complications A case report
    Yu, Tiecheng
    Wu, Zhendong
    Mohamed, Sayid Omar
    Ju, Weina
    Liu, Xiuxin
    Qi, Baochang
    MEDICINE, 2020, 99 (12)
  • [38] Open reduction and internal fixation using multiple nonabsorbable suture materials in acute patella fracture: comparison of clinical and radiological outcome with tension band wiring
    Lee, Kwang Won
    Ma, Sang Beom
    Yang, Dae Suk
    Oh, Seung Hak
    Park, Seong Ho
    KNEE SURGERY & RELATED RESEARCH, 2021, 33 (01)
  • [39] Open reduction and internal fixation using multiple nonabsorbable suture materials in acute patella fracture: comparison of clinical and radiological outcome with tension band wiring
    Kwang Won Lee
    Sang Beom Ma
    Dae Suk Yang
    Seung Hak Oh
    Seong Ho Park
    Knee Surgery & Related Research, 33
  • [40] Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation
    Zderic, Ivan
    Stoffel, Karl
    Sommer, Christoph
    Hoentzsch, Dankward
    Gueorguiev, Boyko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (08): : 1749 - 1757