3D Effective Atomic Number Estimation for X-Ray Security Inspection Systems

被引:0
|
作者
Yalcin, Ozan [1 ]
机构
[1] Hacettepe Univ, TR-06750 Ankara, Turkiye
关键词
X-Ray Imaging; Three Dimensional Effective Atomic Number; 3D-Zeff; Multi-Dimensional Effective Atomic Number; ENERGY; PARAMETERIZATION; DENSITY;
D O I
10.1117/12.3024840
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Public places, such as airports, factories, public institutions, and organizations, require advanced security measures. X-Ray systems are often used to check passengers' luggage. Researchers and technologists are constantly working to improve the baggage-checking process by implementing various methods. This study introduces a new method for estimating the effective atomic number. Traditionally, effective atomic number estimation relies on the ratio between high-energy and low-energy images. However, the 3D Effective Atomic Number Estimation model uses high-energy and low-energy image values directly, resolving many issues of the 1D-Ratio model.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Effective atomic number and electron density determination using spectral x-ray CT
    Busi, Matteo
    Kehres, Jan
    Khalil, Mohamad
    Olsen, Ulrik L.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) IV, 2019, 10999
  • [42] Effective atomic number measurement with energy-resolved X-ray computed tomography
    Kanno, Ikuo
    Yamashita, Yoshiki
    Kimura, Masashi
    Inoue, Fukutaro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 121 - 124
  • [43] SELECTION AND USE OF X-RAY SYSTEMS FOR SECURITY INSPECTION OF CARRY-ON LUGGAGE AT AIRPORTS
    ZIMMERMA.RL
    HEALTH PHYSICS, 1974, 27 (06): : 654 - 654
  • [44] Improved imaging for X-ray inspection systems
    Eilbert, RF
    Shi, SH
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 2005, 20 (03) : 23 - 28
  • [45] Large container X-ray inspection systems
    2003, Ishikawajima-Harima Heavy Industries Co. (43):
  • [46] PREDICTING THE PERFORMANCE OF 3D X-RAY COMPUTERIZED-TOMOGRAPHY SYSTEMS
    SIVERS, EA
    HOLLOWAY, DA
    ELLINGSON, WA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 345 (01): : 179 - 197
  • [47] Ultra Fast X-ray Detection Systems in Nanometer and 3D Technologies
    Grybos, Pawel
    Drozd, Aleksandra
    Deptuch, Grzegorz
    Kasinski, Krzysztof
    Kleczek, Rafal
    Kmon, Piotr
    Maj, Piotr
    Otfinowski, Piotr
    Rauza, Jacek
    Szczygiel, Robert
    Satlawa, Tomasz
    Zoladz, Miroslaw
    2014 PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS & SYSTEMS (MIXDES), 2014, : 38 - 41
  • [48] X-ray systems for optimizing PCB inspection
    Lehmann, David K.
    Circuits Assembly, 2002, 13 (02): : 35 - 39
  • [49] A Discussion on Performance Verification of 3D X-Ray Computed Tomography Systems
    Moroni, Giovanni
    Petro, Stefano
    15TH CIRP CONFERENCE ON COMPUTER AIDED TOLERANCING, CIRP CAT 2018, 2018, 75 : 125 - 130
  • [50] 3D reconstruction of x ray CT image for nondestructive inspection
    Yoshizawa, Satoshi
    Tanaka, Toshiyuki
    Kikuchi, Kazuo
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 189 - +