3D Effective Atomic Number Estimation for X-Ray Security Inspection Systems

被引:0
|
作者
Yalcin, Ozan [1 ]
机构
[1] Hacettepe Univ, TR-06750 Ankara, Turkiye
关键词
X-Ray Imaging; Three Dimensional Effective Atomic Number; 3D-Zeff; Multi-Dimensional Effective Atomic Number; ENERGY; PARAMETERIZATION; DENSITY;
D O I
10.1117/12.3024840
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Public places, such as airports, factories, public institutions, and organizations, require advanced security measures. X-Ray systems are often used to check passengers' luggage. Researchers and technologists are constantly working to improve the baggage-checking process by implementing various methods. This study introduces a new method for estimating the effective atomic number. Traditionally, effective atomic number estimation relies on the ratio between high-energy and low-energy images. However, the 3D Effective Atomic Number Estimation model uses high-energy and low-energy image values directly, resolving many issues of the 1D-Ratio model.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] 3D atomic imaging of SiGe system by X-ray fluorescence holography
    K. Hayashi
    Y. Takahashi
    E. Matsubara
    K. Nakajima
    N. Usami
    Journal of Materials Science: Materials in Electronics, 2003, 14 : 459 - 462
  • [22] 3D atomic imaging of SiGe system by X-ray fluorescence holography
    Hayashi, K
    Takahashi, Y
    Matsubara, E
    Nakajima, K
    Usami, N
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2003, 14 (5-7) : 459 - 462
  • [23] 3D CT X-ray imaging fills inspection gaps, says Xradia
    Vogler, Debra
    SOLID STATE TECHNOLOGY, 2011, 54 (05) : 9 - 9
  • [24] Portable X-ray inspection systems
    不详
    INSIGHT, 2003, 45 (04) : 289 - 289
  • [25] X-ray inspection systems and applications
    Kovács, R
    27th International Spring Seminar on Electronics Technology, Books 1-3, Conference Proceedings: MEETING THE CHALLENGES OF ELECTRONICS TECHNOLOGY PROGRESS, 2004, : 14 - 19
  • [26] Spectrozonal x-ray detector for determining the effective atomic number of absorbing tissue
    Lelyukhin A.S.
    Kornev E.A.
    Kan'Shin V.V.
    Biomedical Engineering, 2004, 38 (5) : 227 - 232
  • [27] X-ray computed tomography for effective atomic number and density evaluation: A review
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [28] Calculation of Effective Atomic Number and Normal Density Using a Source Weighting Method in a Dual Energy X-ray Inspection System
    Park, Ji Sung
    Kim, Jong Kyung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (04) : 2709 - 2713
  • [29] 3D/2D image registration: The impact of X-ray views and their number
    Tomazevic, Dejan
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 450 - +
  • [30] 2-D and 3-D X-ray inspection systems - What do they mean?