Adaptive intensity modulated proton therapy using 4D robust planning: a proof-of-concept for the application of dose mimicking approach

被引:1
|
作者
Kaushik, Suryakant [1 ,2 ,3 ]
Stuetzer, Kristin [4 ,5 ,6 ]
Oeden, Jakob [1 ]
Fredriksson, Albin [1 ]
Toma-Dasu, Iuliana [2 ,3 ]
机构
[1] RaySearch Labs AB Publ, Stockholm, Sweden
[2] Stockholm Univ, Dept Phys, Med Radiat Phys, Stockholm, Sweden
[3] Karolinska Inst, Dept Oncol & Pathol, Med Radiat Phys, Stockholm, Sweden
[4] Tech Univ Dresden, Fac Med, OncoRay Natl Ctr Radiat Res Oncol, Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
[5] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
[6] Inst Radiooncol OncoRay, Helmholtz Zentrum Dresden Rossendorf, Dresden, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 18期
基金
欧盟地平线“2020”;
关键词
adaptive planning; adaptive proton therapy; 4D robust optimisation; dose mimicking; variable RBE; biologically consistent dose accumulation; RELATIVE BIOLOGICAL EFFECTIVENESS; EFFECTIVENESS UNCERTAINTIES; OPTIMIZATION; MOTION; DELIVERY; ACCOUNT; RANGE; MODEL;
D O I
10.1088/1361-6560/ad75e0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. A four-dimensional robust optimisation (4DRO) is usually employed when the tumour respiratory motion needs to be addressed. However, it is computationally demanding, and an automated method is preferable for adaptive planning to avoid manual trial-and-error. This study proposes a 4DRO technique based on dose mimicking for automated adaptive planning. Approach. Initial plans for 4DRO intensity modulated proton therapy were created on an average CT for four patients with clinical target volume (CTV) in the lung, oesophagus, or pancreas, respectively. These plans were robustly optimised using three phases of four-dimensional computed tomography (4DCT) and accounting for setup and density uncertainties. Weekly 4DCTs were used for adaptive replanning, using a constant relative biological effectiveness (cRBE) of 1.1. Two methods were used: (1) template-based adaptive (TA) planning and (2) dose-mimicking-based adaptive (MA) planning. The plans were evaluated using variable RBE (vRBE) weighted doses and biologically consistent dose accumulation (BCDA). Main results. MA and TA plans had comparable CTV coverage except for one patient where the MA plan had a higher D98 and lower D2 but with an increased D2 in few organs at risk (OARs). CTV D98 deviations in non-adaptive plans from the initial plans were up to -7.2 percentage points (p.p.) in individual cases and -1.8 p.p. when using BCDA. For the OARs, MA plans showed a reduced mean dose and D2 compared to the TA plans, with few exceptions. The vRBE-weighted accumulated doses had a mean dose and D2 difference of up to 0.3 Gy and 0.5 Gy, respectively, in the OARs with respect to cRBE-weighted doses. Significance. MA plans indicate better performance in target coverage and OAR dose sparing compared to the TA plans in 4DRO adaptive planning. Moreover, MA method is capable of handling both forms of anatomical variation, namely, changes in density and relative shifts in the position of OARs.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] ON-LINE ADAPTIVE INTENSITY MODULATED PROTON THERAPY OF LUNG CANCER - A TREATMENT PLANNING STUDY OF 2D TRACKING
    af Rosenschold, P. Munck
    Aznar, M.
    Nygaard, D. E.
    Persson, G.
    Korreman, S.
    Engelholm, S. A.
    Nystrom, H.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S538 - S539
  • [22] A Novel 4-D Robust Optimization Mitigates Interplay Effect in Intensity Modulated Proton Therapy for Lung Cancer
    Liu, W.
    Schild, S. E.
    Chang, J. Y.
    Liao, Z.
    Shen, J.
    Stoker, J.
    Wen, Z.
    Wong, W. W.
    Sahoo, N.
    Herman, M. G.
    Mohan, R.
    Bues, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S218 - S218
  • [23] A robust proton treatment planning strategy to account the diaphragm motion for the esophagus cancer using 4D CT
    Pan, X.
    Zhang, X.
    Li, Y.
    Mohan, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2409 - 2410
  • [24] How realistic is 4D treatment planning for scanned proton therapy using rigid motion models?
    Knopf, A. C.
    Zhan, Y.
    Boye, D.
    Lomax, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 732 - 732
  • [25] Assessment of CBCT-Based Adaptive Intensity Modulated Proton Therapy (IMPT) Using Automated Planning for Head and Neck Cancer
    Xu, Y.
    Dogan, N.
    Padgett, K.
    De Ornelas, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E165 - E166
  • [26] Using Robust Treatment Planning of Intensity Modulated Proton Therapy to Address Rectal Volume Uncertainty in High Risk Prostate Cancer Patients
    Brackett, A.
    Kaiser, A.
    Kwok, Y.
    Zhu, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E526 - E527
  • [27] Simulations using patient data to evaluate systematic errors that may occur in 4D treatment planning: A proof of concept study
    St James, Sara
    Seco, Joao
    Mishra, Pankaj
    Lewis, John H.
    MEDICAL PHYSICS, 2013, 40 (09)
  • [28] Anatomical robust optimization to account for nasal cavity filling variation during intensity-modulated proton therapy: a comparison with conventional and adaptive planning strategies
    van de Water, Steven
    Albertini, Francesca
    Weber, Damien C.
    Heijmen, Ben J. M.
    Hoogeman, Mischa S.
    Lomax, Antony J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [29] Evaluation of jaws-only intensity modulated radiation therapy treatment plans using Octavius 4D system
    Duong Thanh Tai
    Luong Thi Oanh
    Nguyen Dong Son
    Truong Thi Hong Loan
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2018, 24 (02): : 75 - 78
  • [30] Risk of Distant-to-target Dose Deposition using an Intensity-modulated Volumetric Arc Therapy Planning and Delivery Concept (RapidArc)
    Cooper, P. H.
    Tanyi, J.
    Laub, W.
    Fuss, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S815 - S815