Simulations using patient data to evaluate systematic errors that may occur in 4D treatment planning: A proof of concept study

被引:6
|
作者
St James, Sara [1 ]
Seco, Joao [2 ]
Mishra, Pankaj [1 ]
Lewis, John H. [1 ]
机构
[1] Harvard Univ, Sch Med, Dana Farber Canc Inst, Dept Radiat Oncol,Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
Monte Carlo treatment planning; 4D treatment planning; MONTE-CARLO SIMULATIONS; REAL-TIME TUMOR; RESPIRATORY MOTION; RADIATION-THERAPY; BODY RADIOTHERAPY; LUNG-TUMORS; TRACKING; PHANTOM; INTRAFRACTION; MANAGEMENT;
D O I
10.1118/1.4817244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to present a framework to evaluate the accuracy of four-dimensional treatment planning in external beam radiation therapy using measured patient data and digital phantoms. Methods: To accomplish this, 4D digital phantoms of two model patients were created using measured patient lung tumor positions. These phantoms were used to simulate a four-dimensional computed tomography image set, which in turn was used to create a 4D Monte Carlo (4DMC) treatment plan. The 4DMC plan was evaluated by simulating the delivery of the treatment plan over approximately 5 min of tumor motion measured from the same patient on a different day. Unique phantoms accounting for the patient position (tumor position and thorax position) at 2 s intervals were used to represent the model patients on the day of treatment delivery and the delivered dose to the tumor was determined using Monte Carlo simulations. Results: For Patient 1, the tumor was adequately covered with 95.2% of the tumor receiving the prescribed dose. For Patient 2, the tumor was not adequately covered and only 74.3% of the tumor received the prescribed dose. Conclusions: This study presents a framework to evaluate 4D treatment planning methods and demonstrates a potential limitation of 4D treatment planning methods. When systematic errors are present, including when the imaging study used for treatment planning does not represent all potential tumor locations during therapy, the treatment planning methods may not adequately predict the dose to the tumor. This is the first example of a simulation study based on patient tumor trajectories where systematic errors that occur due to an inaccurate estimate of tumor motion are evaluated. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Real time 4D IMRT treatment planning based on a dynamic virtual patient model: Proof of concept
    Guo, Bingqi
    Xu, X. George
    Shi, Chengyu
    MEDICAL PHYSICS, 2011, 38 (05) : 2639 - 2650
  • [2] 4D perfusion CT of prostate cancer for image-guided radiotherapy planning: A proof of concept study
    Beer, Lucian
    Polanec, Stephan H.
    Baltzer, Pascal A. T.
    Schatzl, Georg
    Georg, Dietmar
    Schestak, Christian
    Dutschke, Anja
    Herrmann, Harald
    Mazal, Peter
    Brendel, Alexander K.
    Shariat, Shahrokh F.
    Ringl, Helmut
    Helbich, Thomas H.
    Apfaltrer, Paul
    PLOS ONE, 2019, 14 (12):
  • [3] A systematic review of 4D MRI techniques for abdominal radiotherapy treatment planning
    Aljaafari, Lamyaa
    Bird, David
    Buckley, David L.
    Al-Qaisieh, Bashar
    Speight, Richard
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5966 - S5967
  • [4] Adaptive intensity modulated proton therapy using 4D robust planning: a proof-of-concept for the application of dose mimicking approach
    Kaushik, Suryakant
    Stuetzer, Kristin
    Oeden, Jakob
    Fredriksson, Albin
    Toma-Dasu, Iuliana
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (18):
  • [5] 4D treatment planning using motion information from 4D-MRI
    Boye, D.
    Lomax, T.
    Knopf, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 732 - 732
  • [6] SENSITIVITY STUDY OF PATIENT RESPIRATORY MOTION UNCERTAINTY ON 4D IMRT PLANNING
    Yan, D.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S23 - S23
  • [7] Impact of the breathing phase on thoracic dose distribution - An IMRT treatment planning study using 4D CT image data
    Werner, R.
    Fehlauer, F.
    Ehrhardt, J.
    Albers, D.
    Cremers, F.
    Schmidt, R.
    Handels, H.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S153 - S153
  • [8] On-Treatment 4D CT Reconstruction From Planning 4D CT Using Linear Amplitude Scaling
    Park, S.
    Jung, J.
    Kim, J.
    Yeo, I.
    Yi, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3434 - 3434
  • [9] A proof of concept study to evaluate the treatment response of aflibercept in wARMD using OCT-A (Canada study)
    Simrat K. Sodhi
    Carmelina Trimboli
    Sivaruben Kalaichandran
    Austin Pereira
    Netan Choudhry
    International Ophthalmology, 2021, 41 : 1697 - 1708
  • [10] A proof of concept study to evaluate the treatment response of aflibercept in wARMD using OCT-A (Canada study)
    Sodhi, Simrat K.
    Trimboli, Carmelina
    Kalaichandran, Sivaruben
    Pereira, Austin
    Choudhry, Netan
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (05) : 1697 - 1708