Simulations using patient data to evaluate systematic errors that may occur in 4D treatment planning: A proof of concept study

被引:6
|
作者
St James, Sara [1 ]
Seco, Joao [2 ]
Mishra, Pankaj [1 ]
Lewis, John H. [1 ]
机构
[1] Harvard Univ, Sch Med, Dana Farber Canc Inst, Dept Radiat Oncol,Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
Monte Carlo treatment planning; 4D treatment planning; MONTE-CARLO SIMULATIONS; REAL-TIME TUMOR; RESPIRATORY MOTION; RADIATION-THERAPY; BODY RADIOTHERAPY; LUNG-TUMORS; TRACKING; PHANTOM; INTRAFRACTION; MANAGEMENT;
D O I
10.1118/1.4817244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work is to present a framework to evaluate the accuracy of four-dimensional treatment planning in external beam radiation therapy using measured patient data and digital phantoms. Methods: To accomplish this, 4D digital phantoms of two model patients were created using measured patient lung tumor positions. These phantoms were used to simulate a four-dimensional computed tomography image set, which in turn was used to create a 4D Monte Carlo (4DMC) treatment plan. The 4DMC plan was evaluated by simulating the delivery of the treatment plan over approximately 5 min of tumor motion measured from the same patient on a different day. Unique phantoms accounting for the patient position (tumor position and thorax position) at 2 s intervals were used to represent the model patients on the day of treatment delivery and the delivered dose to the tumor was determined using Monte Carlo simulations. Results: For Patient 1, the tumor was adequately covered with 95.2% of the tumor receiving the prescribed dose. For Patient 2, the tumor was not adequately covered and only 74.3% of the tumor received the prescribed dose. Conclusions: This study presents a framework to evaluate 4D treatment planning methods and demonstrates a potential limitation of 4D treatment planning methods. When systematic errors are present, including when the imaging study used for treatment planning does not represent all potential tumor locations during therapy, the treatment planning methods may not adequately predict the dose to the tumor. This is the first example of a simulation study based on patient tumor trajectories where systematic errors that occur due to an inaccurate estimate of tumor motion are evaluated. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Non-invasive evaluation of energy loss in the pulmonary arteries using 4D phase contrast MR measurement: a proof of concept
    Lee, Namheon
    Taylor, Michael D.
    Hor, Kan N.
    Banerjee, Rupak K.
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [42] Using individual networks to identify treatment targets for eating disorder treatment: a proof-of-concept study and initial data
    Levinson, Cheri A.
    Hunt, Rowan A.
    Keshishian, Ani C.
    Brown, Mackenzie L.
    Vanzhula, Irina
    Christian, Caroline
    Brosof, Leigh C.
    Williams, Brenna M.
    JOURNAL OF EATING DISORDERS, 2021, 9 (01)
  • [43] Using individual networks to identify treatment targets for eating disorder treatment: a proof-of-concept study and initial data
    Cheri A. Levinson
    Rowan A. Hunt
    Ani C. Keshishian
    Mackenzie L. Brown
    Irina Vanzhula
    Caroline Christian
    Leigh C. Brosof
    Brenna M. Williams
    Journal of Eating Disorders, 9
  • [44] Baseline data from the proof of concept study to evaluate the safety and early efficacy of vosoritide for the treatment of growth deficits in MPS IVA and VI
    Fung, Ellen B.
    Gibson, Eden
    Lynch, Leslie
    Madden, Jacqueline
    Kammen, Bamidele
    Chang, Irene
    Harmatz, Paul
    MOLECULAR GENETICS AND METABOLISM, 2025, 144 (02)
  • [45] Feasibility of Using Average Intensity Projection of 4D In-Treatment CBCT for Patient Setup Verification
    Kim, J.
    Hong, C.
    Keum, K.
    Kim, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E536 - E536
  • [46] Virtual 3D planning and patient specific surgical guides for osteotomies around the knee A FEASIBILITY AND PROOF-OF-CONCEPT STUDY
    Victor, J.
    Premanathan, A.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 153 - 158
  • [47] Quantification of mediastinal lymph node movement using 4D CT scan: Implications for radiation treatment planning
    Sher, DJ
    Wolfgang, J
    Niemierko, A
    Choi, N
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S222 - S223
  • [48] Advanced treatment planning using direct 4D optimisation for pencil-beam scanned particle therapy
    Bernatowicz, Kinga
    Zhang, Ye
    Perrin, Rosalind
    Weber, Damien C.
    Lomax, Antony J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16): : 6595 - 6609
  • [49] Predicting post-TIPS hepatic encephalopathy risk in patients with cirrhosis and refractory ascites: a proof-of-concept study using a 4D MRI perfusional model
    Saltini, D.
    Piscopo, A.
    Nocetti, L.
    Colopi, S.
    Caporali, C.
    Bianchini, M.
    Guasconi, T.
    Casari, F.
    Scoppettuolo, M.
    Prampolini, F.
    Giglio, C.
    Mayorga, A. S. Velasco
    Ascari, F.
    Colecchia, A.
    Schepis, F.
    DIGESTIVE AND LIVER DISEASE, 2024, 56 : S317 - S317
  • [50] A robust proton treatment planning strategy to account the diaphragm motion for the esophagus cancer using 4D CT
    Pan, X.
    Zhang, X.
    Li, Y.
    Mohan, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2409 - 2410