Theoretical study on the effect of temperature gradient on contact-free scanning for scanning ion conductance microscopy

被引:0
|
作者
Wang, Zhiwu [1 ]
Zhuang, Jian [2 ,3 ]
Zhou, Lidong [1 ]
Li, Hongjuan [1 ]
Ning, Shaohui [1 ]
Liao, Xiaobo [4 ]
机构
[1] Taiyuan Univ Sci & Technol, Sch Mech Engn, Taiyuan 030024, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Educ, Minist Modern Design & Rotor Bearing Syst, Xian 710049, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
[4] Southwest Univ Sci & Technol, Sch Mfg Sci & Engn, Mianyang 621010, Peoples R China
基金
中国国家自然科学基金;
关键词
Scanning ion conductance microscopy (SICM); Temperature gradient; Feedback threshold; Finite element modeling; Contact-free scanning; SURFACES;
D O I
10.1016/j.ultramic.2024.114054
中图分类号
TH742 [显微镜];
学科分类号
摘要
Scanning ion-conductance microscopy (SICM) is a non-contact, high-resolution, and in-situ scanning probe microscope technique, it can be operated in probing the physical and chemical properties of biological samples such as living cells. Recently, using SICM to study the effects of microenvironment changes such as temperature changes on response of the biological samples has attracted significant attention. However, in this temperature gradient condition, one of the crucial but still unclear issues is the scanning feedback types and safe threshold. In this paper, a theoretical study of effect of the temperature gradient in electrolyte or sample surface on the SICM safe ion-current threshold is conducted using three-dimensional Poisson-Nernst-Planck, Navier-Stokes and energy equations. Two temperature gradient types, sample surface and two types of pipettes with different ratio of inner and outer radii are included, respectively. The results demonstrate that the local temperature of the electrolyte and then sample surface significantly affect the ion flow, shape of the approach curves and thus safe threshold in SICM pipette probe for contact-free scanning. There is a current-increased and decreased phases for approaching the surface with higher temperature and two current-decreased phases for surface with lower temperature. Based on this shape feature of approach curves, the change rate of current is analysis to illustrate the possibility for contact-free scanning of slope object. The results indicate that with the decrease of the normalized tip-surface distance, the coupling effect of large slope angle and local high temperature makes the increase in change rate of ion current not significant and then it challenging to realize contact-free scanning especially for higher surface temperature.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Effect of sample thickness in elastic modulus mapping with scanning ion conductance microscopy
    Rheinlaender, J.
    Seifert, J.
    Schaeffer, E.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2015, 44 : S81 - S81
  • [42] Novel probe fabrication method for simultaneous scanning electrochemical microscopy and scanning ion conductance microscopy measurements
    Wert, Stefan
    Raith, Timo
    Matysik, Frank-Michael
    PROCEEDINGS OF THE 15TH INTERNATIONAL STUDENTS CONFERENCE MODERN ANALYTICAL CHEMISTRY, 2019, : 79 - 84
  • [43] Integrated Ultramicroelectrode-Nanopipet Probe for Concurrent Scanning Electrochemical Microscopy and Scanning Ion Conductance Microscopy
    Comstock, David J.
    Elam, Jeffrey W.
    Pellin, Michael J.
    Hersam, Mark C.
    ANALYTICAL CHEMISTRY, 2010, 82 (04) : 1270 - 1276
  • [44] Recent advances of scanning electrochemical microscopy and scanning ion conductance microscopy for single-cell analysis
    Zhang, Junjie
    Zhu, Tong
    Lang, Jinxin
    Fu, Wenxuan
    Li, Fei
    CURRENT OPINION IN ELECTROCHEMISTRY, 2020, 22 : 178 - 185
  • [45] Endocytic pathways: combined scanning ion conductance and surface confocal microscopy study
    Andrew I. Shevchuk
    Phil Hobson
    Max J. Lab
    David Klenerman
    Nina Krauzewicz
    Yuri E. Korchev
    Pflügers Archiv - European Journal of Physiology, 2008, 456 : 227 - 235
  • [46] Endocytic pathways: combined scanning ion conductance and surface confocal microscopy study
    Shevchuk, Andrew I.
    Hobson, Phil
    Lab, Max J.
    Klenerman, David
    Krauzewicz, Nina
    Korchev, Yuri E.
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2008, 456 (01): : 227 - 235
  • [47] Membrane patches as ion channel probes for scanning ion conductance microscopy
    Shi, Wenqing
    Zeng, Yuhan
    Zhou, Lushan
    Xiao, Yucheng
    Cummins, Theodore R.
    Baker, Lane A.
    FARADAY DISCUSSIONS, 2016, 193 : 81 - 97
  • [48] Capturing Rare Conductance in Epithelia with Potentiometric-Scanning Ion Conductance Microscopy
    Zhou, Lushan
    Gong, Yongfeng
    Sunq, Abby
    Hou, Jianghui
    Baker, Lane A.
    ANALYTICAL CHEMISTRY, 2016, 88 (19) : 9630 - 9637
  • [49] Scanning Ion Conductance Microscopy Measurement of Paracellular Channel Conductance in Tight Junctions
    Chen, Chiao-Chen
    Zhou, Yi
    Morris, Celeste A.
    Hou, Jianghui
    Baker, Lane A.
    ANALYTICAL CHEMISTRY, 2013, 85 (07) : 3621 - 3628
  • [50] Cell volume measurement using scanning ion conductance microscopy
    Korchev, YE
    Gorelik, J
    Lab, MJ
    Sviderskaya, EV
    Johnston, CL
    Coombes, CR
    Vodyanoy, I
    Edwards, CRW
    BIOPHYSICAL JOURNAL, 2000, 78 (01) : 451 - 457