Theoretical study on the effect of temperature gradient on contact-free scanning for scanning ion conductance microscopy

被引:0
|
作者
Wang, Zhiwu [1 ]
Zhuang, Jian [2 ,3 ]
Zhou, Lidong [1 ]
Li, Hongjuan [1 ]
Ning, Shaohui [1 ]
Liao, Xiaobo [4 ]
机构
[1] Taiyuan Univ Sci & Technol, Sch Mech Engn, Taiyuan 030024, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Educ, Minist Modern Design & Rotor Bearing Syst, Xian 710049, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
[4] Southwest Univ Sci & Technol, Sch Mfg Sci & Engn, Mianyang 621010, Peoples R China
基金
中国国家自然科学基金;
关键词
Scanning ion conductance microscopy (SICM); Temperature gradient; Feedback threshold; Finite element modeling; Contact-free scanning; SURFACES;
D O I
10.1016/j.ultramic.2024.114054
中图分类号
TH742 [显微镜];
学科分类号
摘要
Scanning ion-conductance microscopy (SICM) is a non-contact, high-resolution, and in-situ scanning probe microscope technique, it can be operated in probing the physical and chemical properties of biological samples such as living cells. Recently, using SICM to study the effects of microenvironment changes such as temperature changes on response of the biological samples has attracted significant attention. However, in this temperature gradient condition, one of the crucial but still unclear issues is the scanning feedback types and safe threshold. In this paper, a theoretical study of effect of the temperature gradient in electrolyte or sample surface on the SICM safe ion-current threshold is conducted using three-dimensional Poisson-Nernst-Planck, Navier-Stokes and energy equations. Two temperature gradient types, sample surface and two types of pipettes with different ratio of inner and outer radii are included, respectively. The results demonstrate that the local temperature of the electrolyte and then sample surface significantly affect the ion flow, shape of the approach curves and thus safe threshold in SICM pipette probe for contact-free scanning. There is a current-increased and decreased phases for approaching the surface with higher temperature and two current-decreased phases for surface with lower temperature. Based on this shape feature of approach curves, the change rate of current is analysis to illustrate the possibility for contact-free scanning of slope object. The results indicate that with the decrease of the normalized tip-surface distance, the coupling effect of large slope angle and local high temperature makes the increase in change rate of ion current not significant and then it challenging to realize contact-free scanning especially for higher surface temperature.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effect of Sample Slope on Image Formation in Scanning Ion Conductance Microscopy
    Thatenhorst, Denis
    Rheinlaender, Johannes
    Schaeffer, Tilman E.
    Dietzel, Irmgard D.
    Happel, Patrick
    ANALYTICAL CHEMISTRY, 2014, 86 (19) : 9838 - 9845
  • [22] Scanning ion conductance microscopy for imaging biological samples in liquid: A comparative study with atomic force microscopy and scanning electron microscopy
    Ushiki, Tatsuo
    Nakajima, Masato
    Choi, MyungHoon
    Cho, Sang-Joon
    Iwata, Futoshi
    MICRON, 2012, 43 (12) : 1390 - 1398
  • [23] A cost-efficient approach for simultaneous scanning electrochemical microscopy and scanning ion conductance microscopy
    Wert, Stefan
    Baluchova, Simona
    Schwarzova-Peckova, Karolina
    Sedlakova, Silvia
    Taylor, Andrew
    Matysik, Frank-Michael
    MONATSHEFTE FUR CHEMIE, 2020, 151 (08): : 1249 - 1255
  • [24] A hybrid scanning mode for fast scanning ion conductance microscopy (SICM) imaging
    Zhukov, Alex
    Richards, Owen
    Ostanin, Victor
    Korchev, Yuri
    Klenerman, David
    ULTRAMICROSCOPY, 2012, 121 : 1 - 7
  • [25] A cost-efficient approach for simultaneous scanning electrochemical microscopy and scanning ion conductance microscopy
    Stefan Wert
    Simona Baluchová
    Karolina Schwarzová-Pecková
    Silvia Sedláková
    Andrew Taylor
    Frank-Michael Matysik
    Monatshefte für Chemie - Chemical Monthly, 2020, 151 : 1249 - 1255
  • [26] Hybrid scanning ion conductance and scanning near-field optical microscopy for the study of living cells
    Korchev, YE
    Raval, M
    Lab, MJ
    Gorelik, J
    Edwards, CRW
    Rayment, T
    Klenerman, D
    BIOPHYSICAL JOURNAL, 2000, 78 (05) : 2675 - 2679
  • [27] BIOPHYSICAL APPLICATIONS OF SCANNING ION CONDUCTANCE MICROSCOPY (SICM)
    Anariba, Franklin
    Anh, Joon Hyung
    Jung, Goo-Eun
    Cho, Nam-Joon
    Cho, Sang-Joon
    MODERN PHYSICS LETTERS B, 2012, 26 (05):
  • [28] Electrochemical Impedance Measurements in Scanning Ion Conductance Microscopy
    Shkirskiy, Viacheslav
    Kang, Minkyung
    McPherson, Ian J.
    Bentley, Cameron L.
    Wahab, Oluwasegun J.
    Daviddi, Enrico
    Colburn, Alex W.
    Unwin, Patrick R.
    ANALYTICAL CHEMISTRY, 2020, 92 (18) : 12509 - 12517
  • [29] Experimental Studies of Resolution in Scanning Ion Conductance Microscopy
    Weber, Anna E.
    Baker, Lane A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (14) : H924 - H929
  • [30] Studying of neuronal synapses by scanning ion conductance microscopy
    Gorelik, JV
    Benton, DCH
    Monaghan, A
    Lab, MJ
    Vodyanoy, I
    Klenerman, D
    Moss, GWJ
    Korchev, YE
    BIOPHYSICAL JOURNAL, 2005, 88 (01) : 305A - 305A