Dose assessment in petrous bone CT: Effect of tube current modulation and scan length

被引:0
|
作者
Saga, Zouhir [1 ]
Rahmouni, Abdelaali [1 ]
Talbi, Mohammed [2 ]
Anam, Choirul [3 ]
Rezzouk, Abdellah [1 ]
机构
[1] Sidi Mohamed Ben Abdellah Univ, Fac Sci Dhar El Mahraz, Dept Phys, Lab Solid State Phys, Fes, Morocco
[2] Ibn Tofail Univ, Higher Inst Nursing Profess & Hlth Tech, Fac Sci, Rabat Dept Phys,Lab Mat & Subatom Phys, Kenitra, Morocco
[3] Diponegoro Univ, Fac Math & Sci, Dept Phys, Semarang, Indonesia
关键词
Petrous bone CT; TCM; Scan length; DLP; Effective dose;
D O I
10.1016/j.radphyschem.2024.112125
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this study is to compare the dosimetric performance of two CT acquisition protocols for the petrous bone: a standard fixed mAs protocol and a protocol using tube current modulation (TCM). By analyzing the scan length, dose-length product (DLP) and effective dose (ED) obtained with each protocol, we investigate whether TCM offers an advantage in terms of dose reduction while maintaining comparable image quality. To this end, 249 patients (women: 52%; men: 48%) were included in this study. The first center used TCM (120 kVp, 150 mA reference) for image acquisition, while the other centers opted for fixed mAs values. Acceptability of image quality was assessed using a standardized phantom (model 610 AAPM) by measuring noise uniformity and accuracy, contrast-to-noise ratio (CNR) and spatial resolution. The CTDIvol was not significantly different between center A and the other centers (p > 0.05), while DLP and ED were significantly different (p < 0.001), being reduced by a factor of 2 and 2.23 for scan length. We concluded that a scan with a 14.28% decrease in tube voltage from 140 kVp (136-170-210) mAs fixed to 120 kVp with TCM to 150 mA reference in helical scan mode can be recommended as an optimized protocol during CT examination of petrous bone while reducing DLP and ED to 50% without loss of diagnostic accuracy.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Uncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation
    Salimi, Y.
    Deevband, M. R.
    Ghafarian, P.
    Ay, M. R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (04): : 465 - 472
  • [42] Effect of Localizer Type and Patient Off-Centering On CT Radiation Dose with Use of Automatic Tube Current Modulation
    Ruan, C.
    Sodickson, A.
    Hamberg, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3656 - 3656
  • [43] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [44] Organ dose and scattering dose for CT coronary angiography and calcium scoring using automatic tube current modulation
    Chan, S. W.
    Ho, Y. J.
    Tyan, Y. S.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2013, 56 : 333 - 337
  • [45] Reducing CT Dose During Routine Brain CT Using Attenuation Based Tube Current Modulation (TCM)
    Angel, E.
    Zhang, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3925 - 3925
  • [46] Bismuth Shielding, Organ-based Tube Current Modulation, and Global Reduction of Tube Current for Dose Reduction to the Eye at Head CT
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Grant, Katharine L.
    McCollough, Cynthia H.
    RADIOLOGY, 2012, 262 (01) : 191 - 198
  • [47] Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography
    Lee, E. J.
    Lee, S. K.
    Agid, R.
    Howard, P.
    Bae, J. M.
    terBrugge, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (09) : 1754 - 1759
  • [48] Dose reduction in multidetector CT using attenuation-based online tube current modulation
    Tack, D
    De Maertelaer, V
    Gevenois, PA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 331 - 334
  • [49] Personalized, Scout-Based Dose Estimation for Prospective Optimization of CT Tube Current Modulation
    Medrano, Maria
    Wang, Sen
    Imran, Abdullah-Al-Zubaer
    Stevens, Grant
    Tse, Justin Ruey
    Wang, Adam
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [50] A Preliminary Method of Risk-Informed Optimization of Tube Current Modulation for Dose Reduction in CT
    Gao, Y.
    Liu, T.
    Li, X.
    Liu, B.
    Kalra, M.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3622 - 3622